Analytical balance with glass draft shield and stainless weighing pan
Industrial Scale

Balances

Eight laboratory and workshop balances, from 0.1 mg analytical models with glass draft shields to economical bench balances for counting and formulation.

What This Category Is For

Balances are chosen by readability first and everything else second. This range starts at 0.1 mg for analytical work and steps up through precision and economical models, so a laboratory, a quality room and a production counting bench can all be equipped from one supplier.

Problems It Solves

  • Analytical readings drifting because of draughts across the pan
  • Results that cannot be pushed into a laboratory system without retyping
  • Precision balances bought at the wrong readability for the tolerance being checked
  • Counting jobs done on scales with too coarse a division

Who Buys This Category

  • Quality control and research laboratories
  • Pharmaceutical, food and chemical testing rooms
  • Production counting and formulation benches
  • Educational and calibration laboratories

Core Advantages

  • Analytical models reading to 0.1 mg with glass draft shields
  • RS232C output on analytical models for data capture
  • Precision and economical models for workshop and counting duty
  • Matching E2 and F1 test weights available on the same order
In Use

Typical Application Scenarios

  • Weighing sample material for laboratory analysis

  • Formulating small batches of additives or pigments

  • Counting small fasteners and electronic components by weight

  • Verifying incoming raw material against a certificate

Questions Buyers Ask

Balances Questions

Which readability do I need?

Work back from the smallest tolerance you have to prove. As a rule the balance readability should be at least ten times finer than the tolerance. For 0.1 mg work use an analytical model such as the FA series; for gram level work a precision model is enough and much less sensitive to draughts.

Can the balance send readings to a computer?

The analytical models list an RS232C output interface. Tell us what you are connecting to so we can confirm the cable and settings.

Do balances need a draft shield?

Any balance reading to 1 mg or finer does. The analytical models here are supplied with a glass draft shield as part of the build.

Can you supply calibration weights with the balance?

Yes. Stainless steel E2 and F1 weights ship from the same catalogue, so the balance and the weights used to check it arrive together.

Specify Your Balance With Us

Send the capacity, division, protection rating and destination market. We will confirm the model, the approval documents and the freight before you commit.