500AH Electro Pneumatic Converter OEM Order
An OEM order for the high-output end of the 500 table. The 500-AH is the 4-20 mA unit calibrated to 3-120 psi, the widest output range in the current-input list.
Controlair Type Transducer 500-AH configuration, 4-20 mA input, 3-120 psi (0.2-8.2 BAR) output, 260 ohms
What The Customer Needed
A 3-120 psi output is not a stock configuration. The customer needed the high range in quantity, under their own label, and needed confidence that the units would hold calibration across the whole span rather than only at the ends.
How It Was Built
The 500-AH was built to the published selection table at 260 ohms impedance, and the span adjustment headroom was checked on each unit, since the large span adjustment on this range allows recalibration out to 3-145 psig on the 2-120 psig unit.
What The Photographs Show
Calibration was carried out across the full span rather than at two points only, with intermediate currents checked against the output. The photographs show the batch arranged for that extended check.





How It Finished
A high-range configuration delivered in quantity, under the customer's brand, with the span verified across the range.
The Models Behind This Order
Controlair Type Transducer500X Electro Pneumatic Converter
Controlair pattern E/P converter, 0-5 V, 1-9 V and 0-10 V inputs
View specifications →
Controlair Type Transducer500X Electro Pneumatic Transducer
Controlair pattern I/P transducer, 4-20 mA in, 3-15 to 3-120 psi out
View specifications →
Controlair Type Transducer500AC Electro Pneumatic Transducer
500-AC configuration, 4-20 mA in, 3-15 psi out, 180 ohms
View specifications →
Controlair Type Transducer500ACD Electro Pneumatic Transducer
500-AC range with a plug-in electrical termination
View specifications →Questions About OEM Orders
Can this configuration be supplied under our own brand
Yes. Nameplates are printed to customer artwork and part numbering and checked against the build before fitting.
How is a batch kept consistent
The whole quantity is built in one run and calibrated consecutively on the same bench against the same standard current generator and 0.1 class pressure gauge.
What is the specification on this order
500-AH configuration, 4-20 mA input, 3-120 psi (0.2-8.2 BAR) output, 260 ohms.
Can we order a different range in the same body
Yes. The published selection table or coding system for this pattern lists the available input signals, output ranges and terminations.
Order The Same Configuration
Send the range, the termination and the quantity, and the quotation comes back against the published selection table for this pattern.
Marsh Bellofram Type Transducer
Fairchild Type Transducer
Flowserve Type Transducer
EPC Type Transducer