500AC Electro Pneumatic Transducer OEM Order
An OEM order: the same 4-20 mA to 3-15 psi conversion, supplied with the customer's nameplate, part numbering and packing.
Controlair Type Transducer 500-AC configuration supplied under the customer's own brand
What The Customer Needed
The customer sells the transducer as part of their own valve package and needed the instrument to arrive already carrying their identity, so that it could go straight into their assembly line without relabelling.
How It Was Built
Nameplates were printed to the customer's artwork and part numbering, checked against the build before fitting, and the cartons marked to the customer's specification.
What The Photographs Show
Assembly, nameplate fitting, calibration and batch test run in sequence on the same bench. The photographs show the finished units in rows with their labels visible, which is the point at which label and build are cross-checked.





How It Finished
A shipment that went into the customer's own stock system on arrival with no relabelling step.
The Models Behind This Order
Controlair Type Transducer500AC Electro Pneumatic Transducer
500-AC configuration, 4-20 mA in, 3-15 psi out, 180 ohms
View specifications →
Controlair Type Transducer500X Electro Pneumatic Transducer
Controlair pattern I/P transducer, 4-20 mA in, 3-15 to 3-120 psi out
View specifications →
Controlair Type Transducer500X Electro Pneumatic Converter
Controlair pattern E/P converter, 0-5 V, 1-9 V and 0-10 V inputs
View specifications →
Controlair Type Transducer500ACD Electro Pneumatic Transducer
500-AC range with a plug-in electrical termination
View specifications →Questions About OEM Orders
Can this configuration be supplied under our own brand
Yes. Nameplates are printed to customer artwork and part numbering and checked against the build before fitting.
How is a batch kept consistent
The whole quantity is built in one run and calibrated consecutively on the same bench against the same standard current generator and 0.1 class pressure gauge.
What is the specification on this order
500-AC configuration supplied under the customer's own brand.
Can we order a different range in the same body
Yes. The published selection table or coding system for this pattern lists the available input signals, output ranges and terminations.
Order The Same Configuration
Send the range, the termination and the quantity, and the quotation comes back against the published selection table for this pattern.
Marsh Bellofram Type Transducer
Fairchild Type Transducer
Flowserve Type Transducer
EPC Type Transducer