100W/150W Halogen Lamp Cold Light Source for Microscope
The LG-100 and LG-150 are halogen lamp cold light sources designed for microscope illumination.

Product Overview
The LG-100 and LG-150 are halogen lamp cold light sources designed for microscope illumination. They deliver 60,000Lx and 90,000Lx average illumination respectively, using Osram 64637 (100W) and Philips 13629 (150W) lamps with 3000K and 3200K color temperatures. Both models use a shell and silent fan cooling system to maintain stable light output during extended use.
- ModelLG-100, LG-150
- Input voltage85-265VAC
- Power100W (LG-100), 150W (LG-150)
- Lamp life2000h (Osram 64637), 200h (Philips 13629)
- Color temperature3000K (LG-100), 3200K (LG-150)
- Cooling methodShell + Silent Fan
Key Benefits
- 60,000Lx to 90,000Lx average illumination for bright, even lighting on samples
- 2000-hour lamp life (Osram 64637) and 200-hour life (Philips 13629) for predictable replacement cycles
- 3000K to 3200K color temperature provides neutral white light suitable for inspection and photography
- Silent fan cooling maintains stable temperature without introducing vibration or noise
- Compact host size 245mm x 101mm x 157mm fits under most microscope stands
- Dual input voltage 85-265VAC allows use in multiple countries without a transformer
Application Scenarios
- High-precision inspection of PCBs, SMD components and BGA joints under bright, consistent illumination
- Documentation of metallurgical samples, mineral specimens or biological sections with a stable light source
- Teaching labs requiring uniform lighting across multiple microscope stations
- Jewellery and watchmaking inspection where color accuracy and brightness are critical
- Long-duration microscopy sessions in research or quality control labs without lamp overheating
Who It Is For
- Electronics manufacturers doing PCB, SMD and BGA inspection and rework
- Metallurgy and materials science labs requiring bright, stable illumination
- Teaching and training labs in universities and technical schools
- Jewellery, watchmaking and precision assembly workshops
- Research and clinical laboratories needing consistent lighting for imaging
Problems It Solves
- A standard halogen lamp without a cooling system overheats during long use, risking sample damage or lamp failure
- Low illumination levels make it difficult to see fine details in solder joints, surface defects or microstructures
- Color temperature drift or uneven lighting leads to inconsistent image capture across multiple sessions
- Lamp life shorter than 200 hours requires frequent replacements, increasing downtime and cost
- Noisy cooling fans interfere with quiet lab environments or sensitive measurements
Technical Features
- Halogen lamp cold light source with shell and silent fan cooling
- Input voltage range 85-265VAC for global compatibility
- Average illumination 60,000Lx (LG-100), 90,000Lx (LG-150)
- Lamp life 2000 hours (Osram 64637), 200 hours (Philips 13629)
- Color temperature 3000K (LG-100), 3200K (LG-150)
- Net weight 2.1kg, host size 245mm x 101mm x 157mm
- Box size 290mm x 228mm x 255mm for shipping and storage
Specifications
| Model | LG-100, LG-150 |
|---|---|
| Input voltage | 85-265VAC |
| Power | 100W (LG-100), 150W (LG-150) |
| Lamp life | 2000h (Osram 64637), 200h (Philips 13629) |
| Color temperature | 3000K (LG-100), 3200K (LG-150) |
| Cooling method | Shell + Silent Fan |
| Net weight | 2.1Kg |
| Host size | 245(L) x 101(W) x 157(H)mm |
| Box size | 290(L) x 228(W) x 255(H)mm |
Specifications are taken from the AMADA product data for this item. Confirm critical dimensions with us in writing before ordering.
Customization Options
- Choose between LG-100 (100W, 60,000Lx) and LG-150 (150W, 90,000Lx) based on required illumination level
- Select lamp type based on availability and expected lifespan: Osram 64637 (2000h) or Philips 13629 (200h)
- Use the same host unit with different lamps depending on application needs
Comparison With Other Options
| Basic halogen lamp without cooling | The LG-100 and LG-150 use a shell and silent fan cooling system, preventing overheating during long use and extending lamp life compared to uncooled models. |
|---|---|
| LED cold light source | The halogen lamp provides higher lumen output and a warmer color temperature (3000K-3200K) than most LEDs, which may be preferred for certain inspection tasks or photography. |
| Low-power cold light source (50W) | The LG-100 and LG-150 deliver significantly higher illumination (60,000Lx-90,000Lx) than 50W models, making them suitable for demanding inspection tasks. |
Use Guide
- Mount the cold light source under the microscope stand with the fan facing downward for optimal airflow
- Ensure the input voltage matches your local supply (85-265VAC) before connecting
- Replace the lamp after 2000 hours (Osram 64637) or 200 hours (Philips 13629) to maintain illumination levels
- Do not touch the lamp glass with bare hands; use a cloth or gloves to prevent oil residue
- Allow the unit to cool before replacing the lamp to avoid burns
More From Cold Light Source

XD-303-150W Medical Cold Light Source for ENT, Pet, Veterinary
View Details
XD-300-250W Xenon Cold Light Source Endoscopic Illumination
View Details
XD-301-150/250W Halogen Cold Light Source for Surgery
View Details
XD-300-80W(A) LED Cold Light Source in ENT Gynecology Proctology
View Details
XD-300-50W(B) Mini Xenon Cold Light Source for Endoscope
View Details
XD-300-50W(A) Compact Xenon Cold Light Source for Endoscope
View Details
XD-300 20W LED Cold Light Source for Microscope
View Details
25W LED Lamp Cold Light Source for Microscope LG-25W
View DetailsGuides and Applications
Frequently Asked Questions
What is the difference between LG-100 and LG-150?
The LG-100 uses a 100W lamp with 60,000Lx average illumination and 2000-hour life; the LG-150 uses a 150W lamp with 90,000Lx and 200-hour life.
Which lamp is used in each model?
LG-100 uses Osram 64637; LG-150 uses Philips 13629.
How long does the lamp last?
Osram 64637 lasts 2000 hours; Philips 13629 lasts 200 hours.
Does the cooling fan make noise?
The fan is designed to operate silently under normal conditions, suitable for quiet lab environments.
Can I use this with any microscope?
Yes, as long as the microscope has a compatible light port or adapter for the cold light source.
What is the input voltage range?
85-265VAC, suitable for use in most countries without a voltage transformer.
Request A Price On The 100W/150W Halogen Lamp Cold Light Source for Microscope
Send quantity, destination and the application. We will confirm the configuration, the price and the lead time.