XD-300-250W Xenon Cold Light Source Endoscopic Illumination
The XD-300-250W is a xenon cold light source designed for endoscopic illumination with a daylight-spectrum output, 5,800,000 lx illuminance, and 5,600 K color temperature.

Product Overview
The XD-300-250W is a xenon cold light source designed for endoscopic illumination with a daylight-spectrum output, 5,800,000 lx illuminance, and 5,600 K color temperature. It supports 250W or 350W power settings, offers adjustable brightness, and features a 500-hour bulb lifetime. The unit includes interchangeable interfaces compatible with Wolf, Storz, and Olympus endoscopes, and allows for customizable front panel design.
- Light Source TypeXenon
- Power250/350W
- Illuminance5,800,000 lx
- Color Temperature5,600 K
- Bulb Lifetime500 h
- Weight6,200 g
Key Benefits
- Daylight-spectrum xenon light with 5,600 K color temperature for accurate color rendering
- 5,800,000 lx illuminance ensures high brightness in deep or narrow endoscopic passages
- Adjustable brightness allows fine-tuning for different tissue types and depths
- Interchangeable interfaces support Wolf, Storz, and Olympus endoscope systems
- 500-hour bulb lifetime reduces downtime and replacement frequency
- Customizable front panel design allows branding or lab-specific labeling
- 250W or 350W power options provide flexibility for different illumination needs
Application Scenarios
- Endoscopic surgery in general, urology, or laparoscopy requiring consistent, high-intensity illumination
- Medical training labs using endoscopes with varying connector types
- Diagnostic procedures in gastroenterology or gynecology where color accuracy is critical
- Maintenance and calibration of endoscopic systems with adjustable brightness control
- Custom lab setups requiring branded or labeled equipment for internal tracking
Who It Is For
- Hospitals and surgical centers using endoscopic equipment
- Medical training institutions with endoscopy simulation labs
- Diagnostic clinics performing minimally invasive procedures
- Equipment maintenance teams servicing endoscopes from multiple manufacturers
- Research labs integrating endoscopic imaging into biological or clinical studies
Problems It Solves
- Low illuminance in narrow or deep endoscopic channels limits visibility during procedures
- Inconsistent color temperature distorts tissue appearance and affects diagnosis
- Fixed brightness settings prevent adaptation to different tissue types or depths
- Incompatible connectors between light source and endoscope require adapters or replacements
- Lack of customizable labeling leads to confusion in multi-user or multi-department environments
Technical Features
- Xenon light source with daylight-spectrum output and high Color Rendering Index (CRI)
- Adjustable brightness control for real-time illumination tuning
- Support for 250W or 350W power settings
- Interchangeable interfaces compatible with Wolf, Storz, and Olympus endoscope systems
- Customizable front panel design for branding or lab identification
- 5,800,000 lx illuminance at the output port
- 5,600 K color temperature for natural color representation
- 500-hour bulb lifetime under continuous operation
- 6,200 g weight for stable placement on surgical tables or lab benches
Specifications
| Light Source Type | Xenon |
|---|---|
| Power | 250/350W |
| Illuminance | 5,800,000 lx |
| Color Temperature | 5,600 K |
| Bulb Lifetime | 500 h |
| Weight | 6,200 g |
| Adjustable Brightness | Yes |
| Interchangeable Interfaces | Compatible with Wolf, Storz, Olympus |
| Customizable Front Panel | Yes |
Specifications are taken from the AMADA product data for this item. Confirm critical dimensions with us in writing before ordering.
Customization Options
- Front panel design can be customized for branding or lab-specific labeling
- Interface adapters can be selected or swapped to match Wolf, Storz, or Olympus endoscope connectors
- Power setting can be configured to 250W or 350W based on system requirements
Comparison With Other Options
| LED cold light source for endoscopes | The xenon source offers higher illuminance (5,800,000 lx vs typical LED 1,000,000 lx) and better color rendering, but has shorter bulb life and higher heat output |
|---|---|
| Fixed-output xenon light source | The XD-300-250W allows adjustable brightness, enabling precise control across different procedures, unlike fixed-output models |
| Standard 250W xenon source without interchangeable interfaces | The XD-300-250W supports Wolf, Storz, and Olympus connectors, reducing the need for multiple light sources in multi-brand environments |
Use Guide
- Ensure the selected power setting (250W or 350W) matches the endoscope system's input requirements
- Adjust brightness gradually during procedure to avoid overexposure or underexposure
- Use the correct interface adapter for the endoscope brand to ensure secure connection
- Replace the bulb after 500 hours of operation to maintain optimal illuminance
- Clean the front lens and interface ports regularly to prevent light loss or signal interference
More From Cold Light Source

XD-303-150W Medical Cold Light Source for ENT, Pet, Veterinary
View Details
XD-301-150/250W Halogen Cold Light Source for Surgery
View Details
XD-300-80W(A) LED Cold Light Source in ENT Gynecology Proctology
View Details
XD-300-50W(B) Mini Xenon Cold Light Source for Endoscope
View Details
XD-300-50W(A) Compact Xenon Cold Light Source for Endoscope
View Details
XD-300 20W LED Cold Light Source for Microscope
View Details
25W LED Lamp Cold Light Source for Microscope LG-25W
View Details
150W Halogen Lamp Cold Light Source for Microscope AM-150W
View DetailsGuides and Applications
Frequently Asked Questions
What power settings are available on the XD-300-250W?
The unit supports 250W or 350W power settings, selectable based on the endoscope system and illumination needs.
Which endoscope brands are compatible with this light source?
The XD-300-250W is compatible with Wolf, Storz, and Olympus endoscopes through interchangeable interface adapters.
Can I customize the front panel design?
Yes. The front panel can be customized for branding, lab identification, or internal labeling purposes.
How long does the bulb last?
The xenon bulb has a rated lifetime of 500 hours under continuous operation.
Does the light source require external cooling?
The unit is designed for continuous operation with internal heat management; ensure adequate ventilation during use.
Is the brightness adjustable during use?
Yes. The brightness is adjustable to allow real-time tuning for different tissue types and depths.
Request A Price On The XD-300-250W Xenon Cold Light Source Endoscopic Illumination
Send quantity, destination and the application. We will confirm the configuration, the price and the lead time.