Pharmaceutical lines have a specific contamination source: the equipment itself. Tablet presses, capsule fillers and sieves shed metal, which is why detection normally sits immediately downstream of them.

Pharmaceutical and Cosmetics

What goes wrong

  • Metal wear particles from a tablet press reach the finished batch
  • Stainless steel is the hardest contaminant to detect and the likeliest source
  • Re-tuning at every product change costs validated line time
  • Non-pharmaceutical-grade contact materials fail a hygiene audit
  • Fill weight has to be verified as well as contamination

What the equipment has to do

  • Gravity-fall detection sized for a tablet or capsule stream
  • SUS316 product-contact parts and food-grade channels
  • Automatic rejection with a customised rejecter system
  • Product memory so changeover does not need a re-tune
  • Checkweighing where fill weight is also specified

Typical scenarios

  • Installation after a tablet press, capsule filler or sieve
  • Cosmetics and nutraceutical powder lines
  • Combined metal and fill weight verification
  • Fine chemical production with contamination limits

How we work through it

  • Tell us the equipment the detector sits under and the chute dimensions
  • Aperture, contact materials and rejecter specified to that position
  • Compressed air supply confirmed at 0.5 MPa or more for the rejecter
  • Auto-learning run per product at commissioning and settings stored
  • Verification interval set against your quality plan

What we deliver beyond the equipment

  • IMD series apertures from 72 x 17 mm up to 137 x 25 mm, other sizes to order
  • SUS304 construction with SUS316 product-contact parts
  • Customised rejecter systems and surface treatments
  • Multi-language touch screen interfaces

Pharmaceutical and Cosmetics FAQ

Where should the detector be installed

Immediately after the equipment that sheds metal: the tablet press, capsule filling machine or sieve.

What sensitivity can we expect

Fe 0.3 to 0.5 mm and SUS304 0.6 to 0.8 mm measured on a test sample in the channel. Your product will differ and we will say so.

What are the product-contact materials

SUS316 contact parts with a food-grade plexiglass channel and SUS304 main construction.

What aperture sizes are available

72 x 17 mm, 87 x 15 mm and 137 x 25 mm as standard, with other sizes made to order.

Can we verify fill weight at the same point

Not on the gravity detector, but the VKD-II combines conveyor metal detection with check weighing on one frame.

Equipment for pharmaceutical and cosmetics

Send your requirement and we will specify against it, including what documentation the factory can supply for your market.