L6E3 Single Point Load Cell
Single point cell for decks up to 450 x 450 mm, 50 kg to 300 kg.

Product Overview
The L6E3 sits between the 400 mm and 600 mm single point families. It covers 50 kg to 300 kg on decks up to 450 x 450 mm, which solves the common design problem of a platform that is slightly too large for a 400 mm rated cell but does not justify stepping up to a 600 mm family.
| Capacity | 50 kg to 300 kg |
|---|---|
| Accuracy classes | C3D, C3, C3G |
| Approval | OIML R60 C3 |
| Maximum platform | 450 x 450 mm |
| Output sensitivity | 2.0 ±0.2 mV/V |
| Input / output resistance | 409 ±6 ohm / 350 ±3 ohm |
| n max by class | 2500 (C3D), 3000 (C3), 4000 (C3G) |
| Safe / ultimate overload | 150 % / 300 % of full scale |
Category: Load Cells
Key Benefits
- 450 x 450 mm platform limit fills the gap between the 400 mm and 600 mm families
- Three accuracy grades with n max from 2500 to 4000
- OIML R60 C3 approval for trade builds
- Integral structure that installs without a sub frame
Problems It Solves
- Deck designs that just exceed a 400 mm cell limit
- Corner error on platforms sized between standard families
- Multiple cell families needed to cover one product line
Who It Is For
- Scale builders with a 420 to 450 mm deck design
- Pricing and platform scale manufacturers
- OEMs standardising on a single cell across a product range
Application Scenarios
- 200 kg bench scale with a 450 mm square deck
- Pricing scale with a larger than standard pan
- Packing bench scale for boxed goods
Technical Features
- Capacities 50, 100, 150, 200, 250 and 300 kg
- Aluminium construction with parallel beam design
- Silicon adhesive sealed, surface anodised and anti-corrosion
- Integral structure for easy installation
- Maximum platform size 450 x 450 mm
Full Specification Data
These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.
| Capacity | kg | 50/100/150/200/250/300 | ||
| Accuracy | C3D | C3 | C3G | |
| Approvals | OIML R60 C3 | |||
| Maximum number of verification intervals | n max | 2500 | 3000 | 4000 |
| Minimum load cell verification interval | v min | Emax/5000 | Emax/7000 | Emax/11000 |
| Combined error | (%FS) | ≤±0.030 | ≤±0.020 | ≤±0.015 |
| Creep | (%FS/30min) | ≤±0.020 | ≤±0.0167 | ≤±0.0125 |
| Temperature effect on sensitivity | (%FS/10℃) | ≤±0.021 | ≤±0.0175 | ≤±0.0131 |
| Temperature effect on zero | (%FS/10℃) | ≤±0.028 | ≤±0.020 | ≤±0.0127 |
| Output sensitivity | (mv/v) | 2.0±0.2 | ||
| Input resistance | (Ω) | 409±6 | ||
| Output resistance | (Ω) | 350±3 | ||
| Insulation resistance | (MΩ) | ≥5000(50VDC) | ||
| Zero balance | (%FS) | 2 | ||
| Temperature,compensated | (℃) | -10~+40 | ||
| Temperature,operating | (℃) | -35~+65 | ||
| Excitation, Recommended | (V) | 5~12(DC) | ||
| Excitation,Max | (V) | 18(DC) | ||
| Safe overload | (%FS) | 150 | ||
| Ultimate overload | (%FS) | 300 | ||
| Corner correction | 0.02% load value/100mm | |||
Materials And Construction
- Anodised aluminium body
Customisation Options
- Accuracy class C3D, C3 or C3G
- Capacity from the published range
- Cable length on request
Use Guide
- Confirm the finished deck size before choosing between the L6E and L6E3
- Mount on a machined flat surface with even fixing torque
- Select the accuracy grade from the division count you have to certify
Certification
- OIML R60 C3
How It Compares
| L6E single point cell | Identical capacity band and classes, but the L6E is limited to 400 x 400 mm while the L6E3 allows 450 x 450 mm. |
|---|---|
| L6T single point cell | The L6T allows 600 x 600 mm and runs to 1000 kg. Use it when the deck or the capacity outgrows the L6E3. |
Often Ordered With This Model

L6E Single Point Load Cell
Mid range single point cell, 50 kg to 300 kg on a 400 x 400 mm platform, OIML approved.
View specifications →
L6T Single Point Load Cell
Highest capacity single point cell in the range, up to 1000 kg on a 600 x 600 mm platform.
View specifications →
L6G Single Point Load Cell
Large deck single point cell, 50 kg to 600 kg on a 600 x 600 mm platform.
View specifications →Single Point Load Cells And Platform Size Limits
Six aluminium single point families, six different platform limits. This is the number that decides the design, and it is published for every family.
OIML R60 Accuracy Classes Explained For Scale Builders
Every load cell datasheet in this catalogue is a table of accuracy classes. This is how to read the columns and turn them into a decision.
L6E3 Single Point Load Cell Questions
Why choose the L6E3 over the L6E?
Deck size. The L6E3 is rated for 450 x 450 mm rather than 400 x 400 mm, with the same capacity range and classes.
Does it carry OIML approval?
Yes, OIML R60 C3.
What is the maximum capacity?
300 kg. Above that use the L6G to 600 kg or the L6T to 1000 kg.
Get A Quotation For The L6E3 Single Point Load Cell
Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.