L6E Single Point Load Cell
Mid range single point cell, 50 kg to 300 kg on a 400 x 400 mm platform, OIML approved.

Product Overview
The L6E is the standard mid range single point cell: 50 kg to 300 kg, a 400 x 400 mm platform limit and OIML approval, offered in three accuracy grades so one family covers a basic scale and a higher division model. It is the usual choice for pricing scales and general purpose bench platform scales.
| Capacity | 50 kg to 300 kg |
|---|---|
| Accuracy classes | C3D, C3, C3G |
| Approval | OIML R60 C3 |
| Maximum platform | 400 x 400 mm |
| Output sensitivity | 2.0 ±0.2 mV/V |
| Input / output resistance | 406 ±6 ohm / 350 ±3 ohm |
| n max by class | 2500 (C3D), 3000 (C3), 4000 (C3G) |
| Corner correction | 0.02 percent of load value per 100 mm |
Category: Load Cells
Key Benefits
- Three accuracy grades, C3D, C3 and C3G, from one family
- OIML approval for scales sold into trade use
- Capacity steps at 50, 60, 80, 100, 150, 200 and 300 kg
- 400 x 400 mm platform limit suits standard bench decks
Problems It Solves
- One design that needs both an economy and a high division version
- Approval requirements that a non approved cell cannot meet
- Deck sizes just beyond what a small cell can carry
Who It Is For
- Pricing scale manufacturers
- Bench and platform scale builders from 50 kg to 300 kg
- Distributors holding replacement cells for installed scales
Application Scenarios
- 150 kg bench platform scale with 50 g divisions
- Pricing scale for a market counter
- Parcel weighing bench in a dispatch area
Technical Features
- Capacities 50, 60, 80, 100, 150, 200 and 300 kg
- Aluminium construction with parallel beam design
- Silicon adhesive sealed, surface anodised and anti-corrosion
- Integral structure for easy installation
- Maximum platform size 400 x 400 mm
Full Specification Data
These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.
| Capacity | (kg) | 50/60/80/100/150/200/300 | ||
| Accuracy | C3D | C3 | C3G | |
| Approvals | OIML R60 C3 | |||
| Maximum number of verification intervals | n max | 2500 | 3000 | 4000 |
| Minimum load cell verification interval | v min | Emax/5000 | Emax/7000 | Emax/11000 |
| Combined error | (%FS) | ≤±0.030 | ≤±0.020 | ≤±0.015 |
| Creep | (%FS/30min) | ≤±0.020 | ≤±0.0167 | ≤±0.0125 |
| Temperature effect on sensitivity | (%FS/10℃) | ≤±0.021 | ≤±0.0175 | ≤±0.0131 |
| Temperature effect on zero | (%FS/10℃) | ≤±0.028 | ≤±0.020 | ≤±0.0127 |
| Output sensitivity | (mv/v) | 2.0±0.2 | ||
| Input resistance | (Ω) | 406±6 | ||
| Output resistance | (Ω) | 350±3 | ||
| Insulation resistance | (MΩ) | ≥5000(50VDC) | ||
| Zero balance | (%FS) | 2 | ||
| Temperature,compensated | (℃) | -10~+40 | ||
| Temperature,operating | (℃) | -35~+65 | ||
| Excitation, Recommended | (V) | 5~12(DC) | ||
| Excitation,Max | (V) | 18(DC) | ||
| Safe overload | (%FS) | 150 | ||
| Ultimate overload | (%FS) | 300 | ||
| Corner correction | 0.02% load value/100mm | |||
Materials And Construction
- Anodised aluminium body
Customisation Options
- Accuracy class C3D, C3 or C3G
- Capacity from the published range
- Cable length on request
Use Guide
- Choose C3G where the finished scale must certify 4000 divisions
- Keep the deck within 400 x 400 mm and mount on a rigid block
- Match capacity to the full scale plus deck weight plus margin
Certification
- OIML R60 C3
How It Compares
| L6E3 single point cell | Same capacity band, but the L6E3 allows a slightly larger 450 x 450 mm platform. Choose the L6E3 when the deck is just over 400 mm. |
|---|---|
| L6G single point cell | The L6G runs to 600 kg on a 600 x 600 mm platform. Move up when either capacity or deck size exceeds the L6E limits. |
Often Ordered With This Model

L6E3 Single Point Load Cell
Single point cell for decks up to 450 x 450 mm, 50 kg to 300 kg.
View specifications →
L6G Single Point Load Cell
Large deck single point cell, 50 kg to 600 kg on a 600 x 600 mm platform.
View specifications →
L6N Single Point Load Cell
Single point cell aimed at electronic balances, 3 kg to 100 kg on a 400 x 400 mm platform.
View specifications →Single Point Load Cells And Platform Size Limits
Six aluminium single point families, six different platform limits. This is the number that decides the design, and it is published for every family.
How To Choose Load Cell Capacity And Accuracy Class
Capacity and accuracy class are the two numbers that decide whether a scale can be built and verified. Here is how to derive both before you commit to a design.
L6E Single Point Load Cell Questions
What is the difference between C3D, C3 and C3G?
They are different n max and v min combinations on the same physical cell: 2500, 3000 and 4000 verification intervals respectively, with tighter combined error as the class rises.
Is this cell OIML approved?
Yes, the family carries OIML R60 C3 approval.
What is the largest deck I can build on it?
400 x 400 mm. Beyond that the corner correction figure no longer holds.
Get A Quotation For The L6E Single Point Load Cell
Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.