Load Cells

L6E Single Point Load Cell

Mid range single point cell, 50 kg to 300 kg on a 400 x 400 mm platform, OIML approved.

Product Overview

The L6E is the standard mid range single point cell: 50 kg to 300 kg, a 400 x 400 mm platform limit and OIML approval, offered in three accuracy grades so one family covers a basic scale and a higher division model. It is the usual choice for pricing scales and general purpose bench platform scales.

Key specifications
Capacity50 kg to 300 kg
Accuracy classesC3D, C3, C3G
ApprovalOIML R60 C3
Maximum platform400 x 400 mm
Output sensitivity2.0 ±0.2 mV/V
Input / output resistance406 ±6 ohm / 350 ±3 ohm
n max by class2500 (C3D), 3000 (C3), 4000 (C3G)
Corner correction0.02 percent of load value per 100 mm

Category: Load Cells

Key Benefits

  • Three accuracy grades, C3D, C3 and C3G, from one family
  • OIML approval for scales sold into trade use
  • Capacity steps at 50, 60, 80, 100, 150, 200 and 300 kg
  • 400 x 400 mm platform limit suits standard bench decks

Problems It Solves

  • One design that needs both an economy and a high division version
  • Approval requirements that a non approved cell cannot meet
  • Deck sizes just beyond what a small cell can carry

Who It Is For

  • Pricing scale manufacturers
  • Bench and platform scale builders from 50 kg to 300 kg
  • Distributors holding replacement cells for installed scales

Application Scenarios

  • 150 kg bench platform scale with 50 g divisions
  • Pricing scale for a market counter
  • Parcel weighing bench in a dispatch area
Technical

Technical Features

  • Capacities 50, 60, 80, 100, 150, 200 and 300 kg
  • Aluminium construction with parallel beam design
  • Silicon adhesive sealed, surface anodised and anti-corrosion
  • Integral structure for easy installation
  • Maximum platform size 400 x 400 mm
Specifications

Full Specification Data

These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.

Manufacturer specification table 1
Capacity(kg)50/60/80/100/150/200/300
AccuracyC3DC3C3G
ApprovalsOIML R60 C3
Maximum number of verification intervalsn max250030004000
Minimum load cell verification intervalv minEmax/5000Emax/7000Emax/11000
Combined error(%FS)≤±0.030≤±0.020≤±0.015
Creep(%FS/30min)≤±0.020≤±0.0167≤±0.0125
Temperature effect on sensitivity(%FS/10℃)≤±0.021≤±0.0175≤±0.0131
Temperature effect on zero(%FS/10℃)≤±0.028≤±0.020≤±0.0127
Output sensitivity(mv/v)2.0±0.2
Input resistance(Ω)406±6
Output resistance(Ω)350±3
Insulation resistance(MΩ)≥5000(50VDC)
Zero balance(%FS)2
Temperature,compensated(℃)-10~+40
Temperature,operating(℃)-35~+65
Excitation, Recommended(V)5~12(DC)
Excitation,Max(V)18(DC)
Safe overload(%FS)150
Ultimate overload(%FS)300
Corner correction0.02% load value/100mm

Materials And Construction

  • Anodised aluminium body

Customisation Options

  • Accuracy class C3D, C3 or C3G
  • Capacity from the published range
  • Cable length on request

Use Guide

  • Choose C3G where the finished scale must certify 4000 divisions
  • Keep the deck within 400 x 400 mm and mount on a rigid block
  • Match capacity to the full scale plus deck weight plus margin

Certification

  • OIML R60 C3
Comparison

How It Compares

Compared with alternatives in this catalogue
L6E3 single point cellSame capacity band, but the L6E3 allows a slightly larger 450 x 450 mm platform. Choose the L6E3 when the deck is just over 400 mm.
L6G single point cellThe L6G runs to 600 kg on a 600 x 600 mm platform. Move up when either capacity or deck size exceeds the L6E limits.

Scale Manufacturing And OEMRetail And Market Trade

Questions Buyers Ask

L6E Single Point Load Cell Questions

What is the difference between C3D, C3 and C3G?

They are different n max and v min combinations on the same physical cell: 2500, 3000 and 4000 verification intervals respectively, with tighter combined error as the class rises.

Is this cell OIML approved?

Yes, the family carries OIML R60 C3 approval.

What is the largest deck I can build on it?

400 x 400 mm. Beyond that the corner correction figure no longer holds.

Get A Quotation For The L6E Single Point Load Cell

Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.