L6T Single Point Load Cell
Highest capacity single point cell in the range, up to 1000 kg on a 600 x 600 mm platform.

Product Overview
The L6T takes single point construction as far as it goes in this catalogue: 1000 kg on a 600 x 600 mm platform. For a manufacturer it removes a whole assembly step, because a one tonne bench can be built without four cells, a summing box and corner trimming.
| Capacity | 50 kg to 1000 kg |
|---|---|
| Accuracy classes | C3D, C3, C3G |
| Approval | OIML R60 C3 |
| Maximum platform | 600 x 600 mm |
| Output sensitivity | 2.0 ±0.2 mV/V |
| Input / output resistance | 406 ±6 ohm / 350 ±3 ohm |
| n max by class | 2500 (C3D), 3000 (C3), 4000 (C3G) |
| Safe / ultimate overload | 150 % / 300 % of full scale |
Category: Load Cells
Key Benefits
- Single cell construction up to 1000 kg removes the summing box and trimming step
- 600 x 600 mm platform limit on the full capacity range
- Three accuracy grades with n max up to 4000
- OIML R60 C3 approval for trade scales
Problems It Solves
- Four cell assemblies adding cost and calibration time at 500 kg to 1000 kg
- Corner trimming labour on every unit produced
- Large decks that exceed smaller single point limits
Who It Is For
- Platform and pricing scale manufacturers
- Equipment builders needing a one tonne weighing module
- Assemblers cutting build time on higher capacity benches
Application Scenarios
- 1000 kg heavy bench scale for a workshop
- Drum and bin weighing station
- High capacity packing bench in a distribution centre
Technical Features
- Capacities 50, 75, 100, 150, 200, 250, 300, 500, 635 and 1000 kg
- Aluminium construction with parallel beam design
- Silicon adhesive sealed, surface anodised and anti-corrosion
- Integral structure for easy installation
- Maximum platform size 600 x 600 mm
Full Specification Data
These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.
| ◆L6T load cells are available in the capacities 50kg to 1000kg . ◆Alumium construction with parallel beam. ◆Silicon adhesive sealed, surface anodized and anti-corrosion. ◆Intergral structure and easy installation. ◆Suitable for electronic platform scales, electronic pricing scales and other electronic weighing devices. | Features ◆Capacity : 50kg to 1000kg . ◆High accuracy. ◆Max . platform size: 600x600mm . |
| Capacity | (kg) | 50/75/100/150/200/250/300/500/635/1000 | ||
| Accuracy | C3D | C3 | C3G | |
| Approvals | OIML R60 C3 | |||
| Maximum number of verification intervals | n max | 2500 | 3000 | 4000 |
| Minimum load cell verification interval | v min | Emax/5000 | Emax/7000 | Emax/11000 |
| Combined error | (%FS) | ≤±0.030 | ≤±0.020 | ≤±0.015 |
| Creep | (%FS/30min) | ≤±0.020 | ≤±0.0167 | ≤±0.0125 |
| Temperature effect on sensitivity | (%FS/10℃) | ≤±0.021 | ≤±0.0175 | ≤±0.0131 |
| Temperature effect on zero | (%FS/10℃) | ≤±0.028 | ≤±0.020 | ≤±0.0127 |
| Output sensitivity | (mv/v) | 2.0±0.2 | ||
| Input resistance | (Ω) | 406±6 | ||
| Output resistance | (Ω) | 350±3 | ||
| Insulation resistance | (MΩ) | ≥5000(50VDC) | ||
| Zero balance | (%FS) | 2 | ||
| Temperature,compensated | (℃) | -10~+40 | ||
| Temperature,operating | (℃) | -35~+65 | ||
| Excitation, Recommended | (V) | 5~12(DC) | ||
| Excitation,Max | (V) | 18(DC) | ||
| Safe overload | (%FS) | 150 | ||
| Ultimate overload | (%FS) | 300 | ||
| Corner correction | 0.02% load value/100mm | |||
Materials And Construction
- Anodised aluminium body
Customisation Options
- Accuracy class C3D, C3 or C3G
- Capacity from the published range
- Cable length on request
Use Guide
- Confirm deck weight is included in the capacity calculation at 1000 kg
- Keep within the 600 x 600 mm platform limit regardless of capacity
- Check v min against the intended division before finalising the display
Certification
- OIML R60 C3
How It Compares
| L6G single point cell | Same 600 x 600 mm deck limit, but the L6T carries up to 1000 kg against 600 kg for the L6G. |
|---|---|
| SQB shear beam | At one tonne and above, four SQB shear beams under a floor scale deck become the normal build. The L6T is the single cell option at the boundary. |
Often Ordered With This Model

L6G Single Point Load Cell
Large deck single point cell, 50 kg to 600 kg on a 600 x 600 mm platform.
View specifications →
SQB Shear Beam Load Cell
Shear beam cell specified for floor scales and low platform scales, IP67 and IP68 versions.
View specifications →
L6E3 Single Point Load Cell
Single point cell for decks up to 450 x 450 mm, 50 kg to 300 kg.
View specifications →Single Point Load Cells And Platform Size Limits
Six aluminium single point families, six different platform limits. This is the number that decides the design, and it is published for every family.
How To Choose Load Cell Capacity And Accuracy Class
Capacity and accuracy class are the two numbers that decide whether a scale can be built and verified. Here is how to derive both before you commit to a design.
L6T Single Point Load Cell Questions
What is the largest capacity available?
1000 kg, which is the top of the single point range in this catalogue.
Can I build a 800 x 800 mm deck on it?
No. The published limit is 600 x 600 mm. For larger decks use four shear beam cells and a summing box.
Which accuracy grade supports 4000 divisions?
C3G, with n max 4000 and v min Emax divided by 11000.
Get A Quotation For The L6T Single Point Load Cell
Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.