L6N Single Point Load Cell
Single point cell aimed at electronic balances, 3 kg to 100 kg on a 400 x 400 mm platform.

Product Overview
The L6N is the balance oriented member of the single point family. It covers 3 kg to 100 kg on platforms up to 400 x 400 mm and is offered in a single accuracy class, C3, with n max 3000 and v min Emax divided by 7000, which keeps specification simple for an instrument build.
| Capacity | 3 kg to 100 kg |
|---|---|
| Accuracy class | C3 |
| Approval | OIML R60 C3, n max 3000 |
| Minimum verification interval | Emax / 7000 |
| Maximum platform | 400 x 400 mm |
| Output sensitivity | 2.0 ±0.2 mV/V |
| Input / output resistance | 394 ±6 ohm / 350 ±3 ohm |
| Combined error | Within ±0.020 percent of full scale |
Category: Load Cells
Key Benefits
- Specified for electronic balances and precision bench weighing
- Single C3 class keeps the bill of materials simple
- 400 x 400 mm maximum platform covers most balance decks
- Anodised and silicon sealed aluminium for laboratory and workshop air
Problems It Solves
- Instrument builds complicated by multiple accuracy class options
- Corner errors on wide balance decks
- Cells too coarse for fine division counting work
Who It Is For
- Balance and precision instrument manufacturers
- Counting scale builders in the 3 kg to 100 kg band
- Laboratory equipment makers adding a weighing module
Application Scenarios
- Electronic balance build at 6 kg with 0.1 g division
- Parts counting scale at 30 kg
- Precision bench scale for a quality laboratory
Technical Features
- Capacities 3, 5, 8, 10, 15, 20, 30, 50, 75 and 100 kg
- Aluminium construction with parallel beam design
- Silicon adhesive sealed, surface anodised and anti-corrosion
- Integral structure for easy installation
- Maximum platform size 400 x 400 mm
Full Specification Data
These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.
| Capacity | (kg) | 3/5/8/10/15/20/30/50/75/100 |
| Accuracy | C3 | |
| Approvals | OIML R60 C3 | |
| Maximum number of verification intervals | n max | 3000 |
| Minimum load cell verification interval | v min | Emax/7000 |
| Combined error | (%FS) | ≤±0.020 |
| Creep | (%FS/30min) | ≤±0.0167 |
| Temperature effect on sensitivity | (%FS/10℃) | ≤±0.0175 |
| Temperature effect on zero | (%FS/10℃) | ≤±0.020 |
| Output sensitivity | (mv/v) | 2.0±0.2 |
| Input resistance | (Ω) | 394±6 |
| Output resistance | (Ω) | 350±3 |
| Insulation resistance | (MΩ) | ≥5000(50VDC) |
| Zero balance | (%FS) | 2 |
| Temperature,compensated | (℃) | -10~+40 |
| Temperature,operating | (℃) | -35~+65 |
| Excitation, Recommended | (V) | 5~12(DC) |
| Excitation,Max | (V) | 18(DC) |
| Safe overload | (%FS) | 150 |
| Ultimate overload | (%FS) | 300 |
| Corner correction | 0.02% load value/100mm |
Materials And Construction
- Anodised aluminium body
Customisation Options
- Capacity selected from the published range
- Cable length on request
Use Guide
- Check v min of Emax divided by 7000 against your intended division before finalising the display resolution
- Keep the deck inside 400 x 400 mm and rigid enough not to flex
- Allow the assembly to reach room temperature before final calibration
Certification
- OIML R60 C3
How It Compares
| L6D single point cell | The L6D goes down to 2.5 kg but is limited to a 250 x 350 mm deck. The L6N allows a 400 x 400 mm deck across 3 kg to 100 kg. |
|---|---|
| L6E single point cell | Both allow 400 x 400 mm. The L6E starts at 50 kg and runs to 300 kg, so it takes over where the L6N range ends. |
Often Ordered With This Model

L6D Single Point Load Cell
Smallest single point cell in the range, 2.5 kg to 50 kg on a 250 x 350 mm platform.
View specifications →
L6E Single Point Load Cell
Mid range single point cell, 50 kg to 300 kg on a 400 x 400 mm platform, OIML approved.
View specifications →
GS-B1 Economical Balance
Economical bench balance with auto calibration and counting, 0.1 g and 0.01 g versions.
View specifications →Single Point Load Cells And Platform Size Limits
Six aluminium single point families, six different platform limits. This is the number that decides the design, and it is published for every family.
OIML R60 Accuracy Classes Explained For Scale Builders
Every load cell datasheet in this catalogue is a table of accuracy classes. This is how to read the columns and turn them into a decision.
L6N Single Point Load Cell Questions
Why is only one accuracy class offered?
The family is specified as C3 with n max 3000 and v min Emax divided by 7000, which covers the balance and counting applications it was designed for.
Can I build a 500 x 500 mm balance deck on it?
No. Stay within 400 x 400 mm or move to the L6T or L6G, which allow 600 x 600 mm.
What division can a 30 kg cell support?
v min is 30 divided by 7000, about 4.3 g, so a 5 g division is within the cell specification and a 2 g division is not.