Product Overview

What the ALC-608 Is For

The ALC-608 is a wall mounted alcohol screening terminal that combines breath alcohol testing, facial recognition, body temperature measurement, and access control. It uses a fuel cell sensor for ethanol-specific detection, ensuring results are not affected by mouth alcohol, tobacco smoke, or fuel vapour. The system runs on Android 7.1 with 2GB RAM and 8GB storage, enabling fast processing and secure data handling. It responds in 5 seconds from the start of a breath test and stores up to 20,000 test records and 10,000 registered faces. The unit is designed for fixed-site use with a 12V DC power input and supports multiple units of measurement including mg/L, g/100mL, and mg/mL.

Key Benefits

Why Buyers Pick This Model

  • Fuel cell sensor detects ethanol specifically, avoiding false positives from solvents or smoke
  • Response time of 5 seconds keeps access flow moving during shift checks
  • Facial recognition and body temperature measurement add identity and health verification
  • Stores 20,000 test records and 10,000 registered faces for audit and access tracking
  • Built-in access control prevents entry if alcohol or temperature thresholds are exceeded
  • Android 7.1 system supports secure data handling and future software updates
  • Wall mounted design fits fixed locations like site entrances and control rooms

Application Scenarios

  • Pre-shift screening at mine, construction, and oil and gas site entrances
  • Access control at manufacturing plant gates where alcohol and health checks are required
  • Fleet depot screening where drivers must be cleared before vehicle release
  • Law enforcement checkpoints requiring identity verification and alcohol testing
  • Occupational health screening stations with digital record keeping
  • High security facilities where access is denied based on alcohol or fever readings

Who It Is For

  • Fleet and logistics operators needing automated pre-departure screening
  • Mining and construction contractors enforcing zero alcohol policies at site entry
  • EHS managers requiring defensible records for compliance audits
  • Manufacturing plant safety teams integrating alcohol and health checks into access control
  • Law enforcement and road safety agencies running fixed-site screening operations
  • Distributors of safety instruments looking for a multi-function screening terminal
The Case for Buying It

Problems It Solves

  • Consumer testers with semiconductor sensors produce false positives from mouth alcohol or fuel vapour
  • Manual screening processes slow down shift starts and create inconsistent records
  • Lack of identity verification allows one person to screen multiple times under different names
  • No stored records make it impossible to prove compliance during an audit or dispute
  • Fixed alarm thresholds do not match local legal limits across different markets
  • No integration between alcohol testing and access control allows impaired individuals to enter
How It Works

Technical Features

  • Electrochemical fuel cell sensor for ethanol-specific detection
  • Facial recognition with storage for 10,000 registered faces
  • Body temperature measurement with integrated sensor
  • Response time of 5 seconds from test start
  • Stores 20,000 test records and 10,000 face templates
  • Android 7.1 operating system with 2GB RAM and 8GB storage
  • Supports multiple units: mg/L, g/100mL, mg/mL, and other formats
  • Built-in access control that blocks entry on positive test or elevated temperature
  • Wall mounted design with 32cm x 21cm x 6.5cm dimensions
  • 12V DC power input with AC 100V~240V compatibility
  • Operating temperature range 10°C to 50°C
  • Storage temperature range -20°C to 50°C
  • Humidity tolerance up to 95%
Specifications

Published Specification

These are the figures published for this model. Nothing is carried across from another model in the range.

SensorElectrochemical fuel cell sensor
Operating Temperature10°C to 50°C
Storage Temperature-20°C to 50°C
Humidity95%
Dimensions32cm x 21cm x 6.5cm
Weight1.5KG
PowerDC 12V 3A, AC 100V~240V
Response Time5 seconds
Display UnitsBrAC: mg/L, BAC: g/100mL, mg/mL, or other units
ProcessorSuper quad-core Cortex-A17, up to 1.8GHz
GPUARM Mali-T764, supports TE, ASTC, AFBC
RAM2GB
Storage8GB built-in
SystemAndroid 7.1
Memory10000 registered faces, 20000 test records
How It Is Built

Materials Process and Quality Control

Materials

  • Durable plastic housing with wall mounting bracket
  • Integrated fuel cell sensor module with protective housing
  • Front-facing camera for facial recognition
  • Infrared temperature sensor for non-contact body temperature measurement
  • Internal power supply unit compatible with 12V DC and AC 100V~240V

Manufacturing Process

  • Fuel cell sensor conditioning and burn-in
  • Android 7.1 system installation and firmware loading
  • Facial recognition database setup with test face capture
  • Body temperature sensor calibration against a reference standard
  • Breath test response time and accuracy verification
  • Access control logic testing with simulated entry attempts
  • Final system integration and functional test before packing

Quality Control

  • Every unit is tested for breath response time under 5 seconds
  • Facial recognition accuracy verified with known test faces
  • Body temperature sensor calibrated to a certified reference
  • Access control logic tested with both positive and negative test cases
  • All test records and face templates stored and retrievable
  • Power input tested across 100V to 240V range
Configured Before Shipment

Customisation Options

  • Alarm threshold set to 0.02, 0.05, or 0.08 percent BAC based on destination market
  • Unit of measurement configured to local standard (mg/L, g/100mL, mg/mL, etc.)
  • Facial recognition and access control logic tailored to site security rules
  • Branding on housing and front panel subject to order confirmation
  • Face and test record storage capacity adjusted per site needs
Comparison

How It Compares With the Alternatives

ALC-605 screening terminalThe ALC-608 includes facial recognition and body temperature measurement, while the ALC-605 only does breath alcohol and access control
ALC-213 handheld testerThe ALC-608 is fixed and mains powered for site entry use, while the ALC-213 is portable and battery powered for mobile gate checks
ALC-303 alcohol interlockThe ALC-608 allows access control based on alcohol and temperature, while the ALC-303 prevents engine start based on breath test alone
Consumer breath testersThe ALC-608 uses a fuel cell sensor with traceable calibration, unlike semiconductor testers that drift and cannot be recalibrated
Running the Test

Use Guide

  • Mount the unit on a wall at eye level at the site entrance
  • Power on and allow the system to boot into Android 7.1
  • Register each user’s face using the front camera and assign a test profile
  • Set the alarm threshold to 0.02, 0.05, or 0.08 percent BAC based on local policy
  • When a user approaches, the system captures their face and measures body temperature
  • Prompt the user to blow into the breath inlet for 5 seconds or less
  • The system displays the result and either grants or denies access based on thresholds
  • Record the test and face data for audit purposes
  • Ensure the system is recalibrated and tested monthly to maintain accuracy
FAQ

Questions About the ALC-608

Why does the ALC-608 use a fuel cell sensor instead of a semiconductor one?
A fuel cell sensor detects ethanol specifically and is not affected by acetone, tobacco smoke, or fuel vapour. Semiconductor sensors drift over time and cannot be recalibrated, making their results unreliable for compliance.
Can the alarm threshold be set to match our local legal limit?
Yes. The alarm threshold is configurable to 0.02, 0.05, or 0.08 percent BAC and is set at the service centre before shipment. Specify your market when ordering.
How many faces and test records can the ALC-608 store?
It stores up to 10,000 registered faces and 20,000 test records. This allows for long-term tracking across multiple sites.
Does the terminal measure body temperature?
Yes. It includes a non-contact infrared sensor to measure body temperature as part of the screening process.
How fast is the response time?
The system responds in 5 seconds from the start of the breath test, enabling fast throughput at site entrances.
Can it integrate with access control systems?
Yes. The ALC-608 controls access based on alcohol and temperature results. It can be connected to door locks or gates to block entry on a positive test.
What is the minimum order quantity and lead time?
Both are confirmed per order because they depend on alarm point configuration, unit of measurement, and any branding. Send your quantity and destination market to [email protected] or by WhatsApp and we will confirm in writing.

Quote the Breath Alcohol Tester with Body Temperature ALC-608

Send the quantity, the destination market and the alarm point you need. Configuration is set before shipment, so it is worth agreeing at order time.