Breath Alcohol Tester with Body Temperature ALC-605

Wall mounted alcohol screening terminal with fuel cell sensor, facial recognition, mask detection, and body temperature measurement. Stores 20000 test records and responds in 5 seconds.

ALCOKSON ALC-605 alcohol screening terminal on its stand with the facial recognition screen active
Product Overview

What the ALC-605 Is For

The ALC-605 is a wall mounted alcohol screening terminal with integrated fuel cell breath alcohol detection, facial recognition, mask detection, and body temperature measurement. It is designed for fixed site access control where a person must be screened before entering a facility. The unit runs on Android 7.1, uses a super quad-core processor, and includes a 2GB RAM and 8GB built-in storage. It responds to a breath sample in 5 seconds and stores up to 20,000 test records and 10,000 registered faces. The system supports multiple units for BAC and BrAC and can be configured for local regulatory requirements. It operates on DC12V or AC 100V~240V power and is suitable for indoor use in environments from 10°C to 50°C.

Key Benefits

Why Buyers Pick This Model

  • Integrated fuel cell sensor provides ethanol-specific detection, avoiding false positives from mouth alcohol, smoke, or fuel vapour
  • Response time of 5 seconds allows fast screening without slowing access flow
  • Facial recognition and mask detection ensure the subject is present and properly masked
  • Body temperature measurement adds a health screening layer for site entry
  • Stores 20,000 test records and 10,000 registered faces for audit and access control
  • Runs on DC12V or AC 100V~240V power, suitable for fixed site installation
  • Configurable alarm points and units to match local regulatory thresholds

Application Scenarios

  • Pre-shift screening at mine and construction site entrances with access control
  • Fleet depot entry where drivers must be tested before vehicle keys are issued
  • Oil and gas facility access points requiring multi-factor identity and health screening
  • Manufacturing plant gates where workers must pass alcohol and temperature checks
  • Law enforcement checkpoints with automated screening and identity verification
  • Occupational health screening stations with digital record keeping across multiple sites

Who It Is For

  • Fleet and logistics operators needing automated screening at depot gates
  • Mining and construction contractors enforcing zero alcohol policies at site entry
  • EHS managers requiring a digital audit trail for compliance with safety regulations
  • Oil and gas site operators needing integrated health and identity screening
  • Distributors of safety instruments looking for a fixed terminal with facial recognition
  • Road safety agencies deploying automated screening at high traffic checkpoints
The Case for Buying It

Problems It Solves

  • Consumer breath testers drift and cannot be recalibrated, making results inadmissible in disputes
  • Manual screening at gates slows access and increases human error in recording results
  • Lack of identity verification allows one person to screen multiple workers
  • No body temperature measurement leaves health screening incomplete
  • Fixed alarm thresholds do not match local legal limits, requiring multiple models
  • Instruments without digital storage cannot provide an audit trail for regulatory review
How It Works

Technical Features

  • Fuel cell sensor for ethanol-specific breath alcohol detection
  • Facial recognition with mask detection for identity verification
  • Body temperature measurement integrated into the screening process
  • Response time of 5 seconds from breath sample to result
  • Supports multiple units: BAC in g/100mL, mg/mL, g%, BrAC in mg/L
  • Android 7.1 operating system with super quad-core Cortex-A17 processor
  • 2GB RAM and 8GB built-in storage for system and data
  • ARM Mali-T764 GPU with support for TE, ASTC, AFBC memory compression
  • DC12V 3A or AC 100V~240V power input for fixed site installation
  • Stores up to 10,000 registered faces and 20,000 test records
  • Operating temperature range: 10°C to 50°C
  • Storage temperature range: -20°C to 50°C
  • Humidity tolerance: 95% non-condensing
Specifications

Published Specification

These are the figures published for this model. Nothing is carried across from another model in the range.

SystemAndroid 7.1
Running Memory2GB
Built-in Storage8GB
ProcessorCPU super quad-core Cortex-A17, up to 1.8GHz
GPUARM Mali-T764, supports TE, ASTC, AFBC memory compression
SensorFuel Cell
Working Temperature10°C to 50°C
Storage Temperature-20°C to 50°C
Humidity95% non-condensing
Dimension32cm x 21cm x 6.5cm
Weight1.5KG
BatteryDC12V 3A
Power InputAC 100V~240V
Response Time5 seconds
UnitsBrAC: mg/L, BAC: g%, mg/mL, mg/100mL, or other units
Memory10000 registered faces, 20000 test records
How It Is Built

Materials Process and Quality Control

Materials

  • Impact resistant ABS plastic housing with front-facing sensor array
  • Integrated infrared camera for facial recognition and mask detection
  • Thermal sensor for body temperature measurement
  • Internal fuel cell sensor module with sealed chamber

Manufacturing Process

  • Fuel cell sensor conditioning and burn in
  • Android system installation and firmware loading
  • Facial recognition and mask detection calibration
  • Body temperature sensor alignment and testing
  • Gas calibration against a certified ethanol standard
  • Alarm threshold configuration to the destination market limit
  • Functional breath test and access control test on every unit before packing

Quality Control

  • Every unit is gas calibrated before shipment
  • Facial recognition and mask detection are verified during final test
  • Body temperature measurement is checked against a known thermal source
  • Alarm threshold is confirmed after configuration at the service centre
  • Response time of 5 seconds is verified on every unit
  • Memory capacity for 10,000 faces and 20,000 records is tested
Configured Before Shipment

Customisation Options

  • Alarm point preset to match the destination market’s legal limit
  • Display units configured for local regulatory format (e.g. g/100mL, mg/L)
  • Facial recognition and mask detection sensitivity adjusted per site requirement
  • Branding on housing and front panel subject to order confirmation
  • Power input configuration for local voltage standard
Comparison

How It Compares With the Alternatives

ALC-213 handheld testerThe ALC-605 is fixed and mains powered with facial recognition and temperature, while the ALC-213 is portable and battery powered for gate use
ALC-607 handheld testerThe ALC-607 is handheld with no facial recognition or temperature, while the ALC-605 is a fixed terminal with full biometric screening
ALC-303 alcohol interlockThe ALC-303 prevents engine start, while the ALC-605 controls access and records data without physical engine intervention
ALC-215 handheld testerThe ALC-215 is handheld with no facial recognition, while the ALC-605 is a fixed terminal with integrated identity and health screening
Running the Test

Use Guide

  • Install the unit in a fixed location with stable AC or DC power
  • Ensure the subject stands within 30cm of the sensor array for facial and temperature capture
  • Verify the subject is wearing a mask if required by site policy
  • Prompt the subject to blow steadily into the sensor for 5 seconds
  • Wait for the 5 second response time and confirm the result on the screen
  • Record the result and test counter value for audit purposes
  • Send the unit for recalibration at 500 tests or 12 months, whichever comes first
FAQ

Questions About the ALC-605

Why use a fuel cell sensor in a fixed terminal?
A fuel cell sensor responds only to ethanol, not to acetone, tobacco smoke, or fuel vapour, so it avoids false positives at site entrances.
Can the alarm point be set to our local legal limit?
Yes. The alarm point is configurable between 0.02, 0.05, and 0.08 percent BAC and is set at the service centre before shipment.
How many test records and faces can it store?
It stores up to 20,000 test records and 10,000 registered faces, which supports long-term audit and access control.
Does it work without internet?
Yes. The unit operates offline with full functionality, including facial recognition and access control, but data sync requires internet for remote management.
What is the response time for a breath test?
The unit responds in 5 seconds from the start of the blow, which allows fast throughput at gate checkpoints.
How often does it need recalibration?
Every 500 tests or 12 months, whichever comes first. This interval is documented in the user guide and supports audit readiness.
What is the minimum order quantity and lead time?
Both are confirmed per order because they depend on alarm point configuration and any branding. Send your quantity and destination market to [email protected] or by WhatsApp and we will confirm in writing.

Quote the Breath Alcohol Tester with Body Temperature ALC-605