Dongguan Viboo · Dongguan, China
Averguard logo Request A Quote
Non-Linear Junction Detectors

VT-801 Advanced Non-Linear Junction Detector for High-End Privacy Protection

The VT-801 finds electronic devices that are switched off. It emits an S-band fundamental signal and reads the second and third harmonics that semiconductors return, so a recorder hidden in a wall, ceiling, light fitting or piece of furniture shows up whether or not it is transmitting. An AI algorithm analyses the harmonic pattern to keep the false alarm rate down.

VT-801 non-linear junction detector head and handle

Key benefits

  • Detects devices that are powered off and not transmitting
  • Second and third harmonic detection identifies semiconductor content
  • AI analysis of harmonic patterns for a low false alarm rate
  • Visual, vibration and sound alerts for locating a target
  • Complies with HJ/T10.2 radiation environmental protection guidelines

Problems it solves

  • RF sweeps find nothing when the device is powered off
  • Devices concealed inside walls or furniture cannot be found visually
  • High false alarm rates make a sweep unusable in a furnished room
  • Metal detectors cannot distinguish a recorder from a screw

Who it is for

  • Corporate security teams protecting commercial confidentiality
  • Facility auditors covering sensitive or restricted areas
  • Individuals and hotels checking rooms for surveillance devices

Application scenarios

  • Corporate meeting rooms and confidential offices before a sensitive discussion
  • High-security facility and safety audits of sensitive areas
  • Residential and hotel sweeps for hidden cameras and recorders
  • Checking furniture, walls, ceilings and containers

Technical features

  • S-band fundamental transmission with second and third harmonic reception
  • Embedded artificial intelligence harmonic analysis
  • Non-destructive detection algorithms to reduce false alarms
  • Complies with Ministry of Public Security standard GA1236-2015
  • Tested by the National Quality Supervision and Inspection Center for Safety and Alarm systems

Specifications

Detection PrincipleNon-linear junction, S-band fundamental with 2nd and 3rd harmonic reception
AlertsVisual, vibration and sound
Transmit Power4 W
Battery7.4 V
Operating Timeapproximately 4 hours
Weight1.52 kg, probe 0.05 kg
StandardsGA1236-2015 Nonlinear Junction Detectors
SafetyComplies with HJ/T10.2 radiation environmental protection guidelines
Interface LanguageChinese as supplied - confirm localisation options before ordering

Figures are those published by the factory for this model. Where a value is shown as TBC it is not published, and we will confirm it with the factory before you order rather than estimate it.

Quality control

  • Certified by the National Quality Supervision and Inspection Center for Safety and Alarm systems
  • Compliant with Ministry of Public Security standard GA1236-2015

Compared with other models in the range

The VT-802 is the compact portable version of the same detection principle at around 0.52 kg. The VT-811 adds a wireless signal detection unit that also picks up 5G at 2.6, 3.5 and 4.9 GHz. The VT-801 is the full-size instrument with a 4 W transmitter and roughly 4 hours of operation.

Use guide

  • Charge for a full operating session, roughly 4 hours of use
  • Sweep walls, floors, ceilings, light fittings and furniture systematically
  • Work from the harmonic response rather than expecting an RF signal
  • Use vibration alerts when a sweep must stay silent
  • Re-check any position that alarms from a second angle before concluding

Product images

Where this product is used

Part of Non-Linear Junction Detectors ยท typically specified for:

VT-801 Advanced Non-Linear Junction Detector for High-End Privacy Protection FAQ

Will it find a device that is switched off

Yes. That is the point of non-linear junction detection: it responds to the semiconductor, not to a transmission.

How long does the battery last

Approximately 4 hours, from a 7.4 V pack.

Is it safe to use around people

The device characteristics comply with HJ/T10.2 radiation environmental protection guidelines.

What standard does it meet

Ministry of Public Security standard GA1236-2015 for nonlinear junction detectors, with testing by the National Quality Supervision and Inspection Center for Safety and Alarm systems.

What language is the interface

The source specification describes a Chinese interface. Ask us on WhatsApp about localisation before you order.

How heavy is it to sweep a room

1.52 kg for the unit, with a 0.05 kg probe.

How does it compare with the VT-811

The VT-811 adds wireless signal detection including 5G bands. The VT-801 is the harmonic-only instrument.

Quotation for the VT-801 Advanced Non-Linear Junction Detector for High-End Privacy Protection

Send your destination port and quantity. We will come back with price, lead time and what documentation the factory can supply for your market.