LANP CABLE INDUSTRIAL LIMITED · Cable manufacturer since 2003

Product photograph supplied by the factory. Colour and print are set per order.

Single Core Wire

H07V-R Blue

General Building PVC Wiring Line Strand Cable H07V-R 1.5mm2 2.5mm2 LED Lighting Wire 12 Volt

H07V-R Blue is a stranded cable from the LANP Single Core Wire range. The original specification reads: General Building PVC Wiring Line Strand Cable H07V-R 1.5mm2 2.5mm2 LED Lighting Wire 12 Volt.

It is supplied with a PVC jacket, in Blue. It is available from a 100 m sample reel through to 50,000 m production runs, with typical bulk lead times of 3-7 days.

CategorySingle Core Wire
JacketPVC
ColourBlue
MOQ100 m
Lead Time3-7 days

Reply within 24 hours, including weekends · OEM jacket printing from 1 km · T/T, L/C, Western Union, Escrow

Key Benefits

Why Buyers Specify This Line

Blue Jacket

H07V-R Blue is catalogued in blue, which is how most sites keep this service separate from everything else sharing the same containment.

OEM Branding Available

From 1 km we print your brand on H07V-R Blue rather than putting a sticker on the carton. Packaging design support comes with it.

Tested Before It Ships

H07V-R Blue does not leave the floor untested. Resistance, continuity and dielectric checks run on each production lot, and the records stay with the batch.

Technical Data

Specification Sheet

Values below are the factory specification for H07V-R Blue. Anything not listed is confirmed against the production line before quoting rather than estimated.

Product NameH07V-R Blue
CategorySingle Core Wire
Conductor StructureStranded (flexible)
Jacket MaterialPVC
Jacket ColourBlue
MOQ100 m sample reel, up to 50,000 m per production run
Lead Time3-7 days for bulk production
OEMJacket printing from 1 km, custom packaging available
OriginJieyang, Guangdong, China

Technical Features

  • Stranded (flexible) conductor
  • Jacket printed with specification and rating as standard

Materials

  • Jacket: PVC

Who It Is For

  • Electrical contractors on fixed installation work
  • Panel builders wiring control cabinets with flexible cores
  • Electrical wholesalers stocking a full colour and size ladder
  • Export buyers matching a specific national colour code

Problems It Solves

  • Conductor cross-section under the printed rating
  • Insulation dragging or tearing during long conduit pulls
  • Colour codes that do not match local wiring regulations
  • Coils running short of the marked length

Application Scenarios

  • First-fix conduit and trunking wiring
  • Distribution board tails and final circuits
  • Lighting circuits and switch drops
  • Earthing and bonding conductors
Manufacturing

How This Cable Is Built And Checked

Copper drawing from 8 mm rod

Stranding at controlled lay length

Insulation extrusion at controlled thickness

Jacket extrusion with inline diameter control

Continuity, resistance and dielectric testing

Reeling and packing

Quality Control

  • Conductor resistance measured on every batch
  • Continuity tested end to end before reeling
  • Dielectric strength tested on the finished cable
  • Jacket continuity checked by spark tester

Certification

  • Wstlab CE certification covering 2-core to 22-core power cable at AC450/750 V, 21 A
  • RoHS compliance under EC Council Directive 2011/65/EU
Finished cable reels awaiting inspection at LANP CABLE
Finished reels staged for inspection before packing.
Customisation

What Can Be Changed On This Line

  • Jacket printing with your brand from 1 km per specification
  • Jacket and core colours set per order to match your market's code
  • Custom reel and coil lengths on production runs
  • Box artwork, reel labels and bag printing produced to your design

Compared With Nearby Specifications

AlternativeHow it differs
H07V-K BlackElectrically the same build in a different jacket colour — blue here against black. Colour is how most sites separate services, so it is worth deciding before the order rather than after.
H07V-K GreenElectrically the same build in a different jacket colour — blue here against green. Colour is how most sites separate services, so it is worth deciding before the order rather than after.
Use Guide

Installing It Without Losing Performance

  • Confirm that the marking on H07V-R Blue matches the circuit schedule before pulling. Inspectors read the print on the insulation, not the delivery note.
  • Where H07V-R Blue has to travel a long conduit route, lubricate rather than force it.
  • H07V-R Blue is supplied in blue; confirm that matches the wiring regulations where it will be installed before the order is placed.

Before a first bulk order of H07V-R Blue: request a sample reel. The approved sample becomes the reference every later production lot of this specification is checked against.

Related Products

Other Specifications In The Single Core Wire Range

See all 16 single core wire products →

Related guides

Where it is installed

Questions

H07V-R Blue — Questions

What packing formats are available for H07V-R Blue?

Packing for H07V-R Blue is decided with the order — reels, coils or cartons, in whatever unit length suits the installers.

Can H07V-R Blue be supplied in another jacket colour?

Yes, on a production run. Blue is the stocked colour for H07V-R Blue, and a different code can be extruded if the destination market requires it.

What is the minimum order and lead time for H07V-R Blue?

H07V-R Blue is available from a 100 m sample reel through to 50,000 m production runs, with typical bulk lead times of 3-7 days.

What certification covers H07V-R Blue?

H07V-R Blue falls under our Wstlab CE certificate for power cable at AC450/750 V, 21 A, and RoHS under EC Council Directive 2011/65/EU.

Request pricing on H07V-R Blue

Send quantity, destination and any custom requirement. MOQ from 100 m, bulk lead time 3-7 days.