LANP CABLE INDUSTRIAL LIMITED · Cable manufacturer since 2003

Product photograph supplied by the factory. Colour and print are set per order.

Fire Alarm Cable

2 Core Shielded Red

red fire alarm cable 2x1.5mm fireproof copper wire lsoh lszh jacket

2 Core Shielded Red is built as a 2 core Shielded cable within the LANP Fire Alarm Cable range. The factory specification for this line reads: red fire alarm cable 2x1.5mm fireproof copper wire lsoh lszh jacket.

It is supplied with a LSZH jacket, in Red. Order quantities start at 100 m for evaluation and scale to 50,000 m per run, at a typical bulk lead time of 3-7 days.

CategoryFire Alarm Cable
ShieldingShielded
JacketLSZH
ColourRed
MOQ100 m
Lead Time3-7 days

Reply within 24 hours, including weekends · OEM jacket printing from 1 km · T/T, L/C, Western Union, Escrow

Key Benefits

Why Buyers Specify This Line

Shielded Screening

2 Core Shielded Red carries a Shielded screen, which is what keeps the link usable where the cable has to run alongside mains for a long distance.

LSZH Jacket Option

The LSZH jacket option on 2 Core Shielded Red matters where people have to escape through the space the cable is in — it emits far less smoke and no halogens when it burns.

2 Core Build

With 2 core, 2 Core Shielded Red leaves room for the device that gets added after handover — which is the normal case, not the exception.

Red Jacket

The red jacket on 2 Core Shielded Red is an identification decision as much as a cosmetic one — it is what tells the next contractor what they are looking at.

OEM Branding Available

Your brand can be extruded onto the 2 Core Shielded Red jacket from 1 km per specification, alongside the rating and length markers, with box artwork and reel labels to match.

Tested Before It Ships

Testing on 2 Core Shielded Red happens at the factory, not at your warehouse: continuity end to end, conductor resistance, and dielectric strength on the finished cable.

Technical Data

Specification Sheet

Values below are the factory specification for 2 Core Shielded Red. Anything not listed is confirmed against the production line before quoting rather than estimated.

Product Name2 Core Shielded Red
CategoryFire Alarm Cable
ShieldingShielded
Conductor Diameter1.5 mm
Cores2 core
Jacket MaterialLSZH
Jacket ColourRed
MOQ100 m sample reel, up to 50,000 m per production run
Lead Time3-7 days for bulk production
OEMJacket printing from 1 km, custom packaging available
OriginJieyang, Guangdong, China

Technical Features

  • Shielded
  • Jacket printed with specification and rating as standard

Materials

  • Jacket: LSZH

Who It Is For

  • Fire alarm contractors wiring detection and sounder loops
  • M&E contractors coordinating life safety with other services
  • Maintenance providers extending existing panels
  • Distributors supplying the fire trade

Problems It Solves

  • Fire circuits that cannot be distinguished from general wiring
  • Loop resistance drifting out of the panel's acceptance window
  • Detector loops picking up interference from parallel power runs
  • Compliance documents unavailable at handover

Application Scenarios

  • Detector and call point loops in commercial buildings
  • Sounder and beacon circuits
  • Interface wiring to plant and door hold-open devices
  • Panel extensions on existing systems
Manufacturing

How This Cable Is Built And Checked

Copper drawing from 8 mm rod

Stranding at controlled lay length

Insulation extrusion at controlled thickness

Foil and braid shielding

Jacket extrusion with inline diameter control

Continuity, resistance and dielectric testing

Reeling and packing

Quality Control

  • Conductor resistance measured on every batch
  • Continuity tested end to end before reeling
  • Dielectric strength tested on the finished cable
  • Jacket continuity checked by spark tester

Certification

  • Wstlab CE certification covering 2-core to 22-core fire alarm cable at AC60/750 V, 50/60 Hz
Finished cable reels awaiting inspection at LANP CABLE
Finished reels staged for inspection before packing.
Customisation

What Can Be Changed On This Line

  • Jacket printing with your brand from 1 km per specification
  • Jacket and core colours set per order to match your market's code
  • Custom reel and coil lengths on production runs
  • Box artwork, reel labels and bag printing produced to your design

Compared With Nearby Specifications

AlternativeHow it differs
2 Core Unshielded RedSame family, different screening: this one is Shielded where that one is UTP. Screening changes outside diameter, bend radius and the hardware the link has to terminate into.
4 Core Shielded RedSame construction with a different core count: 2 core here against 4 core. Core count is fixed once the cable is in the wall, so allow spares.
Use Guide

Installing It Without Losing Performance

  • Keep 2 Core Shielded Red in dedicated containment and label both ends before the route is closed up. A life safety circuit has to be identifiable years later.
  • Allow unused cores in every 2 Core Shielded Red run — the next detector or reader will need them.
  • Confirm the 2 Core Shielded Red specification against your drawing before ordering, and request a sample reel so the build can be approved before a bulk run.

Before a first bulk order of 2 Core Shielded Red: request a sample reel. The approved sample becomes the reference every later production lot of this specification is checked against.

Related Products

Other Specifications In The Fire Alarm Cable Range

See all 6 fire alarm cable products →

Related guides

Where it is installed

Questions

2 Core Shielded Red — Questions

What packing formats are available for 2 Core Shielded Red?

Reel, coil and carton formats are all set per order for 2 Core Shielded Red. Tell us how it will be handled on site and we will match the packing to that.

Can 2 Core Shielded Red be supplied in another jacket colour?

2 Core Shielded Red is catalogued in red. Other colours run on production orders, and colour is normally decided at the same time as the jacket print text.

What is the minimum order and lead time for 2 Core Shielded Red?

2 Core Shielded Red is available from a 100 m sample reel through to 50,000 m production runs, with typical bulk lead times of 3-7 days.

What compliance documentation ships with 2 Core Shielded Red?

Wstlab CE certification covering 2-core through 22-core fire alarm cable at AC60/750 V, 50/60 Hz, issued with the 2 Core Shielded Red shipment.

Request pricing on 2 Core Shielded Red

Send quantity, destination and any custom requirement. MOQ from 100 m, bulk lead time 3-7 days.