Load Cells

UDA Aluminium Compression Load Cell

Aluminium compression cell for platform scales and compression testing, 50 kg to 800 kg.

Product Overview

The UDA is a compact aluminium compression cell covering 50 kg to 800 kg in accuracy class C3. It is specified for platform scales and for all kinds of compression testing devices, where a light, rigid cell with a defined installation torque matters more than heavy capacity.

Key specifications
Capacity50 to 800 kg
Accuracy classC3
ProtectionIP65
Input resistance404 ±15 ohm
Output resistance350 ±3 ohm
Excitation10 V DC recommended, 15 V DC maximum
Operating temperature-20 to +50 degrees C
Installation torque25 Nm recommended

Category: Load Cells

Key Benefits

  • Light aluminium construction that keeps assembly weight down
  • Class C3 accuracy for 3000 division builds
  • Defined recommended installation torque of 25 Nm for repeatable mounting
  • Ultimate overload of 300 percent of full scale

Problems It Solves

  • Heavy steel cells adding mass to a portable assembly
  • Inconsistent mounting torque causing drift between units
  • Compression test fixtures needing a defined, repeatable sensor

Who It Is For

  • Platform scale manufacturers in the 50 kg to 800 kg range
  • Test rig and compression testing equipment builders
  • Machine builders adding a weighing point to existing equipment

Application Scenarios

  • Bench platform scale build from 100 kg to 500 kg
  • Compression testing fixture in a quality laboratory
  • Weighing point added to a packing machine frame
Technical

Technical Features

  • Rated capacities 50, 100, 150, 200, 300, 350, 500 and 800 kg
  • Sensitivity 2.0 ±0.2 mV/V, accuracy class C3
  • Aluminium construction with IP65 protection
  • Creep error within ±166 ppm over 30 minutes
  • Cable 2 m at 5 mm diameter
Specifications

Full Specification Data

These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.

Key specifications
Capacity50 to 800 kg
Accuracy classC3
ProtectionIP65
Input resistance404 ±15 ohm
Output resistance350 ±3 ohm
Excitation10 V DC recommended, 15 V DC maximum
Operating temperature-20 to +50 degrees C
Installation torque25 Nm recommended

Materials And Construction

  • Aluminium body

Customisation Options

  • Capacity selected from the published range
  • Cable length on request

Use Guide

  • Tighten to the recommended 25 Nm installation torque so units behave consistently
  • Keep the load purely compressive and axial; this cell is not intended for tension
  • Protect from direct washing, since protection is IP65 rather than IP67 or IP68

Certification

  • Accuracy class C3
Comparison

How It Compares

Compared with alternatives in this catalogue
L6 single point familiesSingle point cells carry a whole platform within a published deck size; the UDA is a compression cell used where the mechanical design already defines the load path.
SQB shear beamThe SQB is a steel beam cell from 0.25 t upward with IP67 and IP68 options; the UDA is the lighter aluminium option below 1 t at IP65.

Scale Manufacturing And OEMLaboratory And Quality Control

Questions Buyers Ask

UDA Aluminium Compression Load Cell Questions

Can the UDA be used in tension?

No. It is a compression cell. For tension use an S type cell such as the H3 or the DEE and DEF family.

Is the UDA suitable for wet areas?

It is IP65, which covers water jets but not immersion. For washdown areas choose a sealed stainless steel cell.

What accuracy class is available?

C3, with creep error within ±166 ppm over 30 minutes and zero balance within ±3 percent of Emax.

Get A Quotation For The UDA Aluminium Compression Load Cell

Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.