UDA Aluminium Compression Load Cell
Aluminium compression cell for platform scales and compression testing, 50 kg to 800 kg.

Product Overview
The UDA is a compact aluminium compression cell covering 50 kg to 800 kg in accuracy class C3. It is specified for platform scales and for all kinds of compression testing devices, where a light, rigid cell with a defined installation torque matters more than heavy capacity.
| Capacity | 50 to 800 kg |
|---|---|
| Accuracy class | C3 |
| Protection | IP65 |
| Input resistance | 404 ±15 ohm |
| Output resistance | 350 ±3 ohm |
| Excitation | 10 V DC recommended, 15 V DC maximum |
| Operating temperature | -20 to +50 degrees C |
| Installation torque | 25 Nm recommended |
Category: Load Cells
Key Benefits
- Light aluminium construction that keeps assembly weight down
- Class C3 accuracy for 3000 division builds
- Defined recommended installation torque of 25 Nm for repeatable mounting
- Ultimate overload of 300 percent of full scale
Problems It Solves
- Heavy steel cells adding mass to a portable assembly
- Inconsistent mounting torque causing drift between units
- Compression test fixtures needing a defined, repeatable sensor
Who It Is For
- Platform scale manufacturers in the 50 kg to 800 kg range
- Test rig and compression testing equipment builders
- Machine builders adding a weighing point to existing equipment
Application Scenarios
- Bench platform scale build from 100 kg to 500 kg
- Compression testing fixture in a quality laboratory
- Weighing point added to a packing machine frame
Technical Features
- Rated capacities 50, 100, 150, 200, 300, 350, 500 and 800 kg
- Sensitivity 2.0 ±0.2 mV/V, accuracy class C3
- Aluminium construction with IP65 protection
- Creep error within ±166 ppm over 30 minutes
- Cable 2 m at 5 mm diameter
Full Specification Data
These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.
| Capacity | 50 to 800 kg |
|---|---|
| Accuracy class | C3 |
| Protection | IP65 |
| Input resistance | 404 ±15 ohm |
| Output resistance | 350 ±3 ohm |
| Excitation | 10 V DC recommended, 15 V DC maximum |
| Operating temperature | -20 to +50 degrees C |
| Installation torque | 25 Nm recommended |
Materials And Construction
- Aluminium body
Customisation Options
- Capacity selected from the published range
- Cable length on request
Use Guide
- Tighten to the recommended 25 Nm installation torque so units behave consistently
- Keep the load purely compressive and axial; this cell is not intended for tension
- Protect from direct washing, since protection is IP65 rather than IP67 or IP68
Certification
- Accuracy class C3
How It Compares
| L6 single point families | Single point cells carry a whole platform within a published deck size; the UDA is a compression cell used where the mechanical design already defines the load path. |
|---|---|
| SQB shear beam | The SQB is a steel beam cell from 0.25 t upward with IP67 and IP68 options; the UDA is the lighter aluminium option below 1 t at IP65. |
Often Ordered With This Model

L6G Single Point Load Cell
Large deck single point cell, 50 kg to 600 kg on a 600 x 600 mm platform.
View specifications →
SQB Shear Beam Load Cell
Shear beam cell specified for floor scales and low platform scales, IP67 and IP68 versions.
View specifications →
H3 S Type Load Cell
Wide range S type cell from 25 kg to 30 t with OIML R60 C3 and C4 approval.
View specifications →Shear Beam S Type And Column Load Cells Compared
Four structures cover nearly every weighing build. Choosing the wrong one creates mounting problems that no amount of calibration will fix.
How To Choose Load Cell Capacity And Accuracy Class
Capacity and accuracy class are the two numbers that decide whether a scale can be built and verified. Here is how to derive both before you commit to a design.
UDA Aluminium Compression Load Cell Questions
Can the UDA be used in tension?
No. It is a compression cell. For tension use an S type cell such as the H3 or the DEE and DEF family.
Is the UDA suitable for wet areas?
It is IP65, which covers water jets but not immersion. For washdown areas choose a sealed stainless steel cell.
What accuracy class is available?
C3, with creep error within ±166 ppm over 30 minutes and zero balance within ±3 percent of Emax.
Get A Quotation For The UDA Aluminium Compression Load Cell
Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.