H3 S Type Load Cell
Wide range S type cell from 25 kg to 30 t with OIML R60 C3 and C4 approval.

Product Overview
The H3 is the widest S type family in this catalogue, covering 25 kg to 30 t in metric and 100 lb to 20 Klb in imperial. Its S beam design accepts tension, compression or both, which is why it appears in crane scales, mechanical scale conversions, hopper scales and a long list of one off weighing devices. Dimensional tables are published per capacity band so the mounting can be designed before the cell arrives.
| Capacity | 0.025 t to 30 t; 100 lb to 20 Klb |
|---|---|
| Accuracy classes | C2, C3, C4, A5S, A5M, B10S, B10M |
| Approval | OIML R60 C3 and C4 |
| Output sensitivity | 2.0 ±0.004 mV/V metric, 3.0 ±0.008 mV/V imperial |
| Input / output resistance | 350 ±3.5 ohm / 351 ±2.0 ohm |
| Excitation | 5 to 12 V DC recommended, 18 V DC maximum |
| Operating temperature | -35 to +65 degrees C |
| Safe / ultimate overload | 150 % / 300 % of full scale |
Category: Load Cells
Key Benefits
- Capacity band from 25 kg to 30 t covers almost any tension weighing job
- OIML R60 approval in both C3 and C4 accuracy classes
- Published dimensional table per capacity band for mounting design
- Tension and compression loading both supported
Problems It Solves
- Mechanical scales that still work but cannot produce a digital record
- Mounting designs held up by missing cell dimensions
- Tension applications where only compression cells were offered
Who It Is For
- Crane and hoist scale manufacturers
- Companies converting mechanical scales to electronic readout
- Hopper, tank and silo weighing integrators
Application Scenarios
- Converting a mechanical platform scale to electronic readout
- Crane scale build for a fabrication workshop
- Suspended hopper weighing in a process plant
Technical Features
- Capacities 25 kg to 30 t and 100 lb to 20 Klb
- Alloy steel, adhesive sealed, oil-proof, waterproof and anti-corrosion
- S beam design for tension and compression loading
- OIML R60 C3 and C4 approval
- Safe and anti-explosive product for harsh environments and hazardous areas
Full Specification Data
These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.
| Capacity | L | H | W1 | W | M | H1 |
| 25~50㎏ | 76.2 (3.0) | 50.8 (2.0) | 12.7 (0.5) | 16.1 (0.63) | M8 | 15.7 (0.62) |
| 0.1~1.5t | 76.2 (3.0) | 50.8 (2.0) | 19.0 (0.75) | 22.4 (0.88) | M10 ×1.5 | 15.3 (0.60) |
| 0.2~0.75t | 76.2 (3.0) | 50.8 (2.0) | 19.0 (0.75) | 22.4 (0.88) | M12 ×1.75 | 13.6 (0.54) |
| 1~1.5t | 76.2 (3.0) | 50.8 (2.0) | 25.4 (1.0) | 28.8 (1.13) | M12×1.75 | 12.1 (0.48) |
| 2~5t | 101.6 (4.0) | 76.2 (3.0) | 25.4 (1.0) | 28.8 (1.13) | M20×1.5 | 20 (0.79) |
| 7.5~10t | 175 (6.89) | 125 (4.92) | 50 (1.97) | / | M33×3 | 40.2 (1.58) |
| 15~20t | 200 (7.89) | 160 (6.3) | 60 (2.36) | / | M42×3 | 51 (2.01) |
| 30t | 230 (9.06) | 190 (7.48) | 80 (3.15) | / | M42×3 | 57.5 (2.26) |
| 100~300lb | 63.5 (2.5) | 50.8 (2.0) | 12.7 (0.5) | 15.9 (0.63) | 1/4—28UNF | 10.1(0.4) |
| 500lb | 63.5 (2.5) | 50.8 (2.0) | 19.05 (0.75) | 22.25 (0.88) | 1/2—20UNF | |
| 0.75~1.5klb | 63.5 (2.5) | 50.8 (2.0) | 19.05 (0.75) | 22.25 (0.88) | 1/2—20UNF | |
| 2~2.5klb | 63.5 (2.5) | 50.8 (2.0) | 25.4 (1.0) | 28.6 (1.13) | 1/2—20UNF | |
| 3klb | 101.6 (4.0) | 76.2 (3.0) | 25.4 (1.0) | 28.6 (1.13) | 1/2—20UNF | 15.24 (0.6) |
| 5~10klb | 101.6 (4.0) | 76.2 (3.0) | 25.4 (1.0) | 28.6 (1.13) | 3/4—16UNF | 15.24 (0.6) |
| 15klb | 139.7 (5.5) | 101.6 (4.0) | 31.75 (1.25) | 34.95 (1.38) | 1—14UNS | 31 (1.22) |
| 20klb | 177.8 (7.0) | 127 (5.0) | 50.8 (2.0) | 54 (2.13) | 5/4—12UNF | 39.9 (1.57) |
| Capacity | t | 0.025/0.05/0.1/0.15/0.2/0.25/0.3/0.5/0.6/0.75/1/1.5/2/2.5/3/5/7.5/10/15/20/30 | ||||||
| lb | 100/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K | |||||||
| Accuracy | C2 | C3 | C4 | A5S | A5M | B10S | B10M | |
| Approval | OIML R60 C3 | OIML R60 C4 | ||||||
| Maximum number of verification intervals | n max | 2000 | 3000 | 4000 | 5000 | 5000 | 10000 | 10000 |
| Minimum load cell verification interval | v min | Emax /5000 | Emax /10000 | Emax /14000 | Emax /15000 | Emax /15000 | Emax /10000 | Emax /10000 |
| Combined error | %FS | ≤±0.030 | ≤±0.020 | ≤±0.018 | ≤±0.018 | ≤±0.026 | ≤±0.035 | ≤±0.050 |
| Creep | %FS /30min | ≤±0.024 | ≤±0.016 | ≤±0.012 | ≤±0.012 | ≤±0.017 | ≤±0.030 | ≤±0.040 |
| Temperature effect on sensitivity | %FS/10℃ | ≤±0.017 | ≤±0.011 | ≤±0.009 | ≤±0.009 | ≤±0.013 | ≤±0.030 | ≤±0.040 |
| Temperature effect on zero | %FS/10℃ | ≤±0.023 | ≤±0.015 | ≤±0.010 | ≤±0.010 | ≤±0.014 | ≤±0.030 | ≤±0.020 |
| Output sensitivity | mv/v | 2.0±0.004(Metric) 3.0±0.008(Imperial) | ||||||
| Input resistance | Ω | 350±3.5 | ||||||
| Output resistance | Ω | 351±2.0 | ||||||
| Insulation resistance | MΩ | ≥ 5000(50VDC) | ||||||
| Zero balance | %FS | 1.5(Metric) 1.0(Imperial) | ||||||
| Temperature, compensated | ℃ | -10~+40 | ||||||
| Temperature, operating | ℃ | -35~+65 | ||||||
| Excitation, Recommended | V | 5~12(DC) | ||||||
| Excitation, Max | V | 18(DC) | ||||||
| Safe overload | %FS | 150 | Ultimate overload | %FS | 300 | |||
Materials And Construction
- Alloy steel body
- Adhesive sealed internals
Customisation Options
- Metric or imperial capacity and thread form
- Accuracy class from C2 to C4
- Cable length on request
Use Guide
- Check the dimensional table for your capacity band before machining brackets, since thread form changes with capacity
- Use rod ends or clevis fittings so the load stays on the loading axis
- Do not exceed the 150 percent safe overload in normal operation
Certification
- OIML R60 C3
- OIML R60 C4
How It Compares
| DEE and DEF S type | The DEE and DEF cover 100 kg to 5 t with IP68 above 1.2 t. The H3 covers a much wider band and adds OIML R60 C3 and C4 approval. |
|---|---|
| H8C shear beam | Use the H8C where the load presses down on a deck and the H3 where it hangs from or pulls on the cell. |
Often Ordered With This Model

DEE And DEF S Type Load Cell
S type tension cell for crane scales, belt scales and blending systems, 100 kg to 5 t.
View specifications →
OCS-C1 Crane Scale
Heavy crane scale from 1 t to 5 t with a swivel hook and remote operation to 10 m.
View specifications →
H8C Single Shear Beam Load Cell
Alloy steel single shear beam cell with OIML and NTEP approval, 0.5 t to 10 t.
View specifications →Shear Beam S Type And Column Load Cells Compared
Four structures cover nearly every weighing build. Choosing the wrong one creates mounting problems that no amount of calibration will fix.
How To Choose Load Cell Capacity And Accuracy Class
Capacity and accuracy class are the two numbers that decide whether a scale can be built and verified. Here is how to derive both before you commit to a design.
H3 S Type Load Cell Questions
What thread sizes are used?
They change with capacity, from M8 at 25 to 50 kg up to M42 x 3 at 30 t, with UNF threads on the imperial capacities. The full dimensional table is published on this page.
Can the H3 be used for a crane scale?
Yes, it is listed for crane scale, mechanical conversion scale and hopper scale duty.
Which accuracy classes carry OIML approval?
C3 and C4 both carry OIML R60 approval in this family.
Get A Quotation For The H3 S Type Load Cell
Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.