XUF100 Upright Research Fluorescence Microscope
The XUF100 is an upright research fluorescence microscope with a one-piece frame and a choice of binocular or trinocular observation tubes.

Product Overview
The XUF100 is an upright research fluorescence microscope with a one-piece frame and a choice of binocular or trinocular observation tubes. It supports 2X to 100X magnification with infinity plan achromatic objectives and includes a Kohler illuminator with field diaphragm. The fluorescence attachment accepts imported UV, V, B, and G excitation filters. It is designed for biological and material research requiring high-resolution imaging under fluorescence illumination.
- Optical systemInfinity plan achromatic
- Head typeBinocular or Trinocular
- Interpupillary adjustment48-75mm or 52-75mm
- Tube inclination30°
- Rotation360°
- Diopter adjustmentYes
Key Benefits
- One-piece frame ensures stability during long observation sessions
- Trinocular tube with 20/80 light split allows simultaneous viewing and camera capture
- Infinity plan achromatic objectives deliver flat, high-contrast images across the field
- Kohler illuminator with field diaphragm provides even illumination and reduces glare
- Multiple objective choices from 2X to 100X (oil immersion) support diverse sample types
- Interchangeable halogen and LED light sources offer flexibility in power and heat output
Application Scenarios
- Fluorescence imaging of stained tissue sections in a clinical or research lab
- Live cell imaging with low-heat LED illumination to avoid sample damage
- Material surface analysis using fluorescent dyes or coatings
- Microbial colony detection under UV or blue excitation
- Documentation of fluorescence patterns with a camera via C-mount adapter
Who It Is For
- Research laboratories in biology, medicine, and materials science
- Clinical pathology labs performing fluorescence-based diagnostics
- University teaching labs requiring stable, configurable fluorescence setups
- Quality control teams inspecting coated or doped materials
- Microscopy labs conducting long-duration imaging sessions
Problems It Solves
- A fixed observation tube limits ergonomic access for multiple users or camera integration
- Poor illumination uniformity causes uneven brightness and reduces image quality
- Lack of a trinocular port forces users to choose between direct viewing and imaging
- Incompatible light sources require separate purchases and power supplies
- Non-infinity optics introduce image distortion at high magnification
Technical Features
- One-piece construction from arm to base for mechanical stability
- Binocular or trinocular observation tube with 30° inclination and 360° rotation
- Interpupillary adjustment range of 48-75mm or 52-75mm depending on tube type
- Diopter adjustment for each eye to accommodate individual vision differences
- Infinity plan achromatic objectives with N.A. from 0.06 to 1.25
- Kohler illuminator with field diaphragm for uniform illumination
- Fluorescence attachment with support for imported UV, V, B, and G excitation filters
- Mechanical stage with 156x138mm or 185x177mm movement range
- Revolving nosepiece with quadruple or quintuple objective positions
- Multiple light source options: 6V20W halogen, 6V30W halogen, or 3W LED with rechargeable battery
Specifications
| Optical system | Infinity plan achromatic |
|---|---|
| Head type | Binocular or Trinocular |
| Interpupillary adjustment | 48-75mm or 52-75mm |
| Tube inclination | 30° |
| Rotation | 360° |
| Diopter adjustment | Yes |
| Objective magnification | 2X, 4X, 10X, 20X(S), 40X(S), 60X(S), 100X(S) (Oil) |
| Objective N.A. | 0.06, 0.10, 0.25, 0.40, 0.65, 0.80, 1.25 |
| Condenser | Abbe Condenser N.A.1.25, Swing-out Condenser |
| Stage type | Mechanical Stage |
| Stage size | 156x138mm or 185x177mm |
| Stage movement range | 76x54mm or 75x50mm |
| Nosepiece | Quadruple inward facing or Quintuple inward facing |
| Illuminator | Kohler with field diaphragm |
| Fluorescence excitation filters | UV, V, B, G (imported) |
| Light source | 6V20W Halogen, 6V30W Halogen, 3W LED (with rechargeable battery) |
| Bulb type | 6V20W Osram Halogen, 6V30W Osram Halogen, 3W LED |
| Fuse rating | 250V/3.15A Φ5X20 |
| Rechargeable battery | 2200mAh LED |
| C-mount adapter | 0.5X, 1X, 0.25X |
| Filter diameter | φ38 |
| Filter types | Blue, Green, Yellow, Frosted glass |
Specifications are taken from the AMADA product data for this item. Confirm critical dimensions with us in writing before ordering.
Customization Options
- Choose between binocular or trinocular observation tubes
- Select trinocular tube with 20/80, 50/50, or 100/0 light split
- Add optional objectives: 2X, 20X(S), 40X(S), 60X(S), 100X(S) (Oil)
- Upgrade to 6V30W halogen or 3W LED with rechargeable battery
- Add C-mount adapters: 0.5X, 1X, 0.25X for camera integration
- Include optional filters: Blue, Green, Yellow, Frosted glass (φ38)
Comparison With Other Options
| XUF101 upright fluorescence microscope | The XUF100 offers a wider range of objective options and supports both 20/80 and 50/50 trinocular light splits; the XUF101 is limited to 100/0 split only. |
|---|---|
| Standard upright biological microscope | The XUF100 includes a Kohler illuminator and fluorescence attachment, which are not standard on basic biological models. |
| Digital fluorescence microscope | The XUF100 uses a traditional optical path with C-mount adaptability, so it supports external cameras and does not rely on built-in digital sensors or software. |
Use Guide
- Adjust the interpupillary distance to match your eye spacing before focusing
- Use the Kohler illuminator to align the light source and condenser for even illumination
- For oil immersion, apply a drop of immersion oil to the 100X objective and clean it after use
- Select the appropriate excitation filter (UV, V, B, G) based on your fluorophore
- Use the 20/80 trinocular split when capturing images with a camera while maintaining a clear view
- Ensure the stage is locked when moving the microscope or transporting it
Guides and Applications
Frequently Asked Questions
What is the maximum magnification with the 100X objective?
100X with the 100X(S) objective; total magnification depends on the eyepiece used (e.g., WF10X/20 gives 1000X total).
Can I use this microscope with a digital camera?
Yes. Use the 1X C-mount adapter to connect a digital camera to the trinocular port.
Does the fluorescence attachment include filters?
The attachment supports imported UV, V, B, and G excitation filters; the filters are not included with the microscope.
What light source options are available?
6V20W halogen, 6V30W halogen, or 3W LED with rechargeable battery; the 3W LED includes a 2200mAh battery.
Is the 100X objective oil immersion?
Yes. The 100X(S) objective requires immersion oil for proper use and maximum resolution.
Can I switch between binocular and trinocular heads?
Yes. The XUF100 body supports both binocular and trinocular head configurations; specify your choice when ordering.
Request A Price On The XUF100 Upright Research Fluorescence Microscope
Send quantity, destination and the application. We will confirm the configuration, the price and the lead time.