AMADA INSTRUMENT CO.,LIMITED — Nanjing China
Microscope Stage

Heated Stage for Stereo Biological Microscope

The KEL-2000B heated stage is designed for stereo microscopes with a 165x130x8mm workbench and a 38mm aperture.

Product Overview

The KEL-2000B heated stage is designed for stereo microscopes with a 165x130x8mm workbench and a 38mm aperture. It operates on 220V±10%, AC45-60Hz, delivers 36V at 50W, and maintains temperature from room temperature to 60°C with a measurement accuracy of ≤±0.2°C across the full range. The digital display allows preset temperature control, and the system adapts to ambient room temperature conditions.

  • ModelKEL-2000B
  • ForStereo Microscope
  • Power supply voltage220V±10%, AC45-60Hz
  • Output voltage36V
  • Power50W
  • Temperature setting methodDigital display, preset

Key Benefits

  • Maintains precise temperature control from room temperature to 60°C for live specimen observation
  • Digital display with preset temperature setting allows repeatable thermal conditions
  • Measurement accuracy of ≤±0.2°C ensures consistent experimental results
  • 165x130x8mm workbench with 38mm aperture fits standard stereo microscope stages
  • 50W output power with 36V output ensures stable heating across the range
  • Adapts to ambient room temperature, so performance is stable in varying lab environments

Application Scenarios

  • Observing live biological specimens such as insect larvae, small invertebrates, or tissue samples under controlled thermal conditions
  • Monitoring cell growth or developmental changes in aquatic microorganisms over time
  • Supporting temperature-sensitive experiments in teaching labs where consistent thermal environments are required
  • Conducting quality checks on temperature-sensitive materials in precision assembly or inspection
  • Enabling long-term observation of dynamic processes in biological or chemical samples

Who It Is For

  • Teaching and research laboratories in biology, zoology, and environmental science
  • Clinical and veterinary labs performing live specimen analysis
  • Quality control departments in biotech and pharmaceuticals requiring thermal stability
  • Universities and technical schools running practical microscopy courses
  • Precision assembly and inspection workshops where thermal conditions affect material behavior

Problems It Solves

  • Standard microscope stages lack temperature control, making live specimen observation unstable
  • Manual temperature adjustment leads to inconsistent results across experiments
  • Inadequate thermal stability causes specimen stress or movement during observation
  • Lack of digital preset control forces repeated calibration and increases operator error
  • Non-uniform heating across the stage leads to uneven sample conditions and unreliable data

Technical Features

  • Digital temperature display with preset function for repeatable settings
  • Heating plate size: 165x130x8mm with a 38mm aperture for optical access
  • Temperature control range: room temperature to 60°C
  • Measurement accuracy: ≤±0.2°C across full range
  • Power supply: 220V±10%, AC45-60Hz
  • Output: 36V, 50W
  • System adapts to ambient room temperature working conditions
  • Stable heating with minimal fluctuation under normal operating conditions

Specifications

ModelKEL-2000B
ForStereo Microscope
Power supply voltage220V±10%, AC45-60Hz
Output voltage36V
Power50W
Temperature setting methodDigital display, preset
Temperature control rangeRoom temperature - 60°C
Measurement accuracyFull range ≤±0.2°C
System working environment temperatureAdaptive room temperature working temperature
Workbench size165x130x8mm
Apertureφ38mm

Specifications are taken from the AMADA product data for this item. Confirm critical dimensions with us in writing before ordering.

Customization Options

  • Available in KEL-2000, KEL-2000A, KEL-2000B, and KEL-2000C variants for upright, inverted, stereo, and sperm microscopes
  • X-4 and X-4H melting point detectors available with extended temperature range up to 300°C
  • Custom aperture size or workbench dimensions possible upon request with engineering review
  • Alternative power input (e.g., 110V) available on request with voltage converter integration

Comparison With Other Options

Standard microscope stage without heatingThe KEL-2000B provides controlled temperature environments, essential for live specimen observation and thermal experiments, while a standard stage offers no thermal regulation.
X-4 Melting Point DetectorThe X-4 reaches up to 300°C with higher power (60W) and different thermal body design; use the KEL-2000B for biological samples up to 60°C, and the X-4 for high-temperature material testing.
KEL-2000A for inverted microscopeThe KEL-2000A has a circular 110mm diameter table; the KEL-2000B has a rectangular 165x130mm workbench suitable for stereo microscopes with larger sample areas.

Use Guide

  • Ensure the microscope stage is clean and dry before mounting the heated stage
  • Connect the stage to a 220V±10%, AC45-60Hz power source; verify voltage compatibility
  • Set the desired temperature using the digital display and preset function
  • Allow 5-10 minutes for the stage to stabilize before placing a sample
  • Avoid placing samples with high moisture content directly on the surface to prevent condensation
  • Do not exceed 60°C to maintain accuracy and prevent damage to the heating element
Answers

Frequently Asked Questions

What is the maximum temperature the KEL-2000B can reach?

60°C, with a control range from room temperature to 60°C.

Does the stage require a separate power supply?

Yes, it requires a 220V±10%, AC45-60Hz power source; it is not powered via USB or microscope interface.

What is the accuracy of the temperature control?

Measurement accuracy is ≤±0.2°C across the full range from room temperature to 60°C.

Can I use this stage with my stereo microscope?

Yes, the KEL-2000B is designed specifically for stereo microscopes with a 165x130mm workbench and 38mm aperture.

Is the digital display easy to read during use?

Yes, the digital display shows the set and actual temperature clearly, with preset function for repeatable settings.

What is the size of the aperture in the heating plate?

The aperture is φ38mm, allowing optical access to the sample under the stage.

Request A Price On The Heated Stage for Stereo Biological Microscope

Send quantity, destination and the application. We will confirm the configuration, the price and the lead time.