Syringe filters, chromatography vials, SPE and biotechnology products are produced according to the ISO 9001 standard system. [email protected] +86-15306778688
Disposable Vacuum Filtration product photo 1
Disposable Vacuum Filtration product photo 2Disposable Vacuum Filtration product photo 3
Lab Filtration Products

Disposable Vacuum Filtration

Disposable Vacuum Filtration is a complete system for filtering and storing aqueous samples under vacuum, designed for routine use in cell culture, biological testing, and environmental analysis. The system includes a polystyrene funnel with a polyethylene neck and a removable polystyrene storage bottle, available in 150 ml, 250 ml, 500 ml, and 1000 ml volumes. Each system uses a single membrane type selected from Nylon, PES, Hydrophilic PVDF, MCE, or CA, with pore sizes of 0.22 or 0.45 micron. The system is supplied in bulk packs of 12 or 24 units, enabling lab-wide standardisation without the need for cleaning or reprocessing.

  • Complete system with funnel, neck, and storage bottle reduces setup time and assembly errors
  • Single-use design eliminates carry-over between samples and avoids cross-contamination
  • Available in four volumes to match sample size and filtration throughput needs
  • Nine membrane options cover aqueous, biological, and mixed solvent matrices
Key Benefits

What This Product Gives You

  • Complete system with funnel, neck, and storage bottle reduces setup time and assembly errors
  • Single-use design eliminates carry-over between samples and avoids cross-contamination
  • Available in four volumes to match sample size and filtration throughput needs
  • Nine membrane options cover aqueous, biological, and mixed solvent matrices
  • Pore sizes of 0.22 and 0.45 micron allow selection for sterile filtration or particulate removal
  • Bulk packing of 12 or 24 units reduces handling and inventory complexity
  • Complete system includes polystyrene funnel with polyethylene neck and removable polystyrene storage bottle
  • Available in four volumes: 150 ml, 250 ml, 500 ml, and 1000 ml
  • Nine membrane options: Nylon, PES, Hydrophilic PVDF, MCE, CA
  • Two pore sizes: 0.22 micron and 0.45 micron
  • Polystyrene funnel and bottle are designed for single-use and vacuum filtration
  • Removable storage bottle allows easy transfer and storage of filtered samples
  • Supplied in packs of 12 (system) or 24 (funnel only) units
Where It Is Used

Applications And Buyers

Application Scenarios

  • Filtering cell culture media and growth factors before use in biological assays
  • Preparing sterile buffers and reagents for microbiology and life-science applications
  • Clarifying environmental water samples for microbial or particulate analysis
  • Processing biological fluids such as serum, plasma, or supernatants in R&D labs
  • Handling high-volume sample batches in pharmaceutical QC without cross-contamination

Who It Is For

  • Pharmaceutical and biotech laboratories requiring sterile filtration of aqueous solutions
  • Environmental testing labs processing multiple water samples with consistent filtration
  • Food and beverage labs filtering protein-rich or particulate-laden samples
  • Contract research organisations standardising filtration across multiple projects
  • Lab distributors sourcing complete, ready-to-use filtration systems for reselling

Problems It Solves

  • Cross-contamination from reusable filtration systems due to incomplete cleaning
  • Time lost assembling separate funnels, bottles, and membranes for each filtration
  • Inconsistent filtration performance when using mismatched components from different suppliers
  • Membrane degradation or leaching in reused systems, especially with biological samples
  • Inadequate storage of filtered samples due to open or non-sterile containers
Data

Specifications

System ComponentsFunnel, polyethylene neck, removable storage bottle
Volume150 ml, 250 ml, 500 ml, 1000 ml
Filter MediaNylon, PES, Hydrophilic PVDF, MCE, CA
Pore Size0.22 micron, 0.45 micron
Funnel MaterialPolystyrene
Neck MaterialPolyethylene
Bottle MaterialPolystyrene
Packing12 pcs per case (system), 24 pcs per case (funnel only)
ApplicationFiltering and storing aqueous solutions, cell culture media, biological fluids

Materials

  • Polystyrene funnel
  • Polyethylene neck
  • Polystyrene storage bottle
  • Membrane selected per application: Nylon, PES, Hydrophilic PVDF, MCE, CA

Customization Options

  • Choice of nine membrane types across 0.22 and 0.45 micron pore sizes
  • OEM private-label printing available through the Microlab OEM division
  • Custom packing configurations possible for bulk orders
  • OEM contract manufacturing and membrane die-cut and packing services available
How It Is Made

Manufacturing And Quality Control

Manufacturing Process

  • Polyethylene neck extrusion and assembly
  • Membrane die-cutting to size
  • Assembly of funnel, neck, and membrane
  • Sealing of membrane into funnel base
  • Packing of complete systems in 12-unit cases or funnels in 24-unit cases

Quality Control

  • Visual inspection of funnel, neck, and bottle for defects before assembly
  • Membrane integrity tested against specified pore size and material
  • Sealing of membrane to funnel verified for vacuum integrity
  • Final system checked for correct volume and component alignment
Comparison

Compared With The Alternatives

Versus Reusable filtration systems

Single-use design eliminates cleaning, carry-over, and reprocessing risks, especially critical for biological and sterile applications

Versus Separate funnels and bottles from different suppliers

Complete system ensures compatibility and consistent performance across all components

Versus Multi-layer or pre-filter systems

Single-layer membrane construction reduces extractables and maintains flow rate for sensitive applications

Versus Generic disposable kits without membrane options

Nine membrane choices allow selection based on sample chemistry, unlike fixed-membrane kits

Use Guide

How To Use It

  • Select the membrane based on sample type: PES or MCE for aqueous solutions, Nylon for mixed solvents, Hydrophilic PVDF for biological fluids
  • Choose 0.22 micron for sterile filtration and 0.45 micron for particulate removal
  • Match the system volume to the sample size to avoid overflow or underutilisation
  • Attach the funnel to a vacuum source and ensure the neck is securely connected to the bottle
  • Pour sample into the funnel and apply vacuum until filtration is complete
  • Remove the bottle and seal it for storage or transfer; do not reuse the system
Photos

Product Gallery

Also In This Category

Related Products

Read Next

Related Industries And Guides

FAQ

Questions Buyers Ask

What membranes are available in the Disposable Vacuum Filtration system?

Available membranes are Nylon, PES, Hydrophilic PVDF, MCE, and CA, with pore sizes of 0.22 and 0.45 micron

What volumes are available?

The system is available in 150 ml, 250 ml, 500 ml, and 1000 ml volumes

Can I reuse the system after filtration?

No. The system is designed for single-use only to prevent cross-contamination and ensure consistent performance

What is the difference between the system and the funnel-only version?

The system includes the funnel, neck, and storage bottle. The funnel-only version (ending in T) is for labs that already have bottles and need only the funnel and membrane

Do you offer private-label packaging?

Yes. The Microlab OEM division supports private-label printing and custom packing for bulk orders

How are the systems packed?

Complete systems are packed in cases of 12 units. Funnel-only versions are packed in cases of 24 units

Get A Quote For Disposable Vacuum Filtration

Tell us the membrane, pore size, diameter and quantity you need, or describe the sample and we will specify it.