Syringe filters, chromatography vials, SPE and biotechnology products are produced according to the ISO 9001 standard system. [email protected] +86-15306778688
Vacuum Pump product photo 1
Vacuum Pump product photo 2Vacuum Pump product photo 3Vacuum Pump product photo 4Vacuum Pump product photo 5Vacuum Pump product photo 6
Lab Filtration Products

Vacuum Pump

The Microlab series of diaphragm vacuum pumps provides oil-free, continuous operation for laboratory filtration and vacuum applications. Designed for precision and reliability, these pumps operate without friction, produce no heat or exhaust, and feature Nitrile Rubber diaphragms for corrosion resistance and long life. They are suitable for use with high-accuracy chromatography systems and as backing pumps for turbo molecular pumps, delivering stable vacuum or controlled air flow across a range of conditions.

  • Oil-free operation ensures no contamination of samples or environment, ideal for sensitive analytical work
  • Nitrile Rubber diaphragm resists corrosion and provides extended operational life under continuous use
  • Self-cooling air draft system enables 24-hour continuous operation without overheating
  • Low noise level below 60 dB allows use in quiet lab environments
Key Benefits

What This Product Gives You

  • Oil-free operation ensures no contamination of samples or environment, ideal for sensitive analytical work
  • Nitrile Rubber diaphragm resists corrosion and provides extended operational life under continuous use
  • Self-cooling air draft system enables 24-hour continuous operation without overheating
  • Low noise level below 60 dB allows use in quiet lab environments
  • Adjustable pressure design supports both vacuum and controlled steady air flow within a defined range
  • High evacuation speed and stable performance make it suitable for chromatography and sample preparation systems
  • Oil-free operation with no working medium required
  • Nitrile Rubber diaphragm for chemical resistance and durability
  • Self-cooling air draft system for 24-hour continuous operation
  • Adjustable pressure control for vacuum or steady air flow
  • Low noise level below 60 dB at full operation
  • Stable vacuum performance with no friction or heat generation
  • Suitable for use as a backing pump for turbo molecular pumps
  • Designed for laboratory-scale precision and reliability
Where It Is Used

Applications And Buyers

Application Scenarios

  • Supporting vacuum filtration in pharmaceutical QC labs for sample concentration and clarification
  • Providing backing vacuum for turbo molecular pumps in high-vacuum analytical instruments
  • Powering vacuum-assisted extraction in environmental and food safety testing
  • Maintaining consistent vacuum during long-duration chromatographic runs in R&D
  • Operating in clean environments where oil contamination must be avoided

Who It Is For

  • Pharmaceutical and biotech laboratories requiring oil-free vacuum for sensitive sample analysis
  • Environmental and food testing labs handling volatile or reactive compounds
  • R&D departments using high-precision chromatography systems that demand stable vacuum
  • Laboratory distributors seeking reliable, low-maintenance vacuum pumps for resale
  • OEMs integrating vacuum pumps into custom filtration or sample preparation systems

Problems It Solves

  • Contamination from oil-lubricated pumps affecting HPLC baselines or sample integrity
  • Overheating and shutdown during extended runs due to inadequate cooling systems
  • Noise interference in quiet lab environments from high-speed rotary pumps
  • Short diaphragm life due to material degradation in aggressive chemical environments
  • Inconsistent vacuum levels during long analytical runs, leading to data variability
Data

Specifications

ModelVP020, VP033A, VP050A, VP050B, VP100A
Speed of Evacuation15 to 60 L/Min
Vacuum200 to 250 mbar
Extreme Pressure≥0.075 Mpa (VP020), ≥0.08 Mpa (VP033A, VP050A, VP100A), ≥0.095 Mpa (VP050B)
Positive Pressure≥30 Psi (VP020, VP100A), NBR (VP033A, VP050A, VP050B)
Motor Power75 W (VP020), 160 W (VP033A, VP050A, VP050B, VP100A)
Voltage Rating220 Vac, 50 Hz
Inlet Sizeφ6 mm
Outlet Sizeφ6 mm (VP020, VP050A, VP050B, VP100A), silencer (VP033A)
Pump Head1 (VP020, VP033A, VP050A), 2 (VP050B, VP100A)
Working Temperature7-40 ℃
Pump Body Temperature<55 ℃
Noise Level<60 dB
Dimensions (L x W x H)245 x 120 x 160 mm (VP020), 270 x 130 x 210 mm (VP033A), 230 x 180 x 265 mm (VP050A), 350 x 130 x 220 mm (VP050B), 310 x 200 x 210 mm (VP100A)
Weight4 kg (VP020), 7 kg (VP033A, VP050A), 7.5 kg (VP050B), 10 kg (VP100A)
FunctionVacuum & Pressure (VP020, VP100A), Vacuum (VP033A, VP050A, VP050B)

Materials

  • Nitrile Rubber diaphragm
  • Metal components with imported axletrees for steady running and low noise
  • Plastic housing with air exchange bin containing filtering material for clean air output

Customization Options

  • OEM contract manufacturing available for private-label branding
  • Custom packaging options for distributors and lab suppliers
  • Adjustable pressure settings can be tailored for specific application needs
  • Integration support for OEMs embedding pumps into larger systems
How It Is Made

Manufacturing And Quality Control

Manufacturing Process

  • Diaphragm assembly using Nitrile Rubber with corrosion-resistant properties
  • Integration of imported axletrees for smooth and efficient rotation
  • Self-cooling air draft system design for continuous operation
  • Air exchange bin with filtering material to ensure clean exhaust air
  • Final assembly and testing under operating conditions to verify vacuum and noise levels

Quality Control

  • Diaphragm integrity tested under vacuum and pressure cycles
  • Noise level measured at full load to ensure <60 dB
  • Pump body temperature monitored during 24-hour run to confirm <55 ℃
  • Vacuum and positive pressure performance verified against specified values
  • Air exhaust filtered and tested for cleanliness before shipment
Comparison

Compared With The Alternatives

Versus Oil-lubricated rotary pumps

Oil-free diaphragm pumps eliminate contamination risk and require no oil changes, reducing maintenance and sample interference

Versus Standard diaphragm pumps with metal diaphragms

Nitrile Rubber diaphragms offer better chemical resistance and longer life in corrosive environments

Versus Pumps without self-cooling systems

The self-cooling air draft system allows 24-hour continuous operation without overheating

Versus Pumps with fixed pressure output

Adjustable pressure design supports both vacuum and controlled air flow for varied lab applications

Use Guide

How To Use It

  • Install the pump on a stable, level surface with adequate ventilation for cooling
  • Connect the inlet to the filtration setup using a compatible φ6 mm tubing
  • Ensure the outlet is vented to atmosphere or connected to a vacuum line as required
  • Set the pressure control to match the required vacuum level or air flow rate
  • Run the pump for 10 minutes before starting sample processing to stabilise performance
  • Monitor temperature and noise during operation; stop if temperature exceeds 55 ℃
  • Use the pump as a backing pump for turbo molecular pumps only when specified
Photos

Product Gallery

Also In This Category

Related Products

Read Next

Related Industries And Guides

FAQ

Questions Buyers Ask

Can this pump be used without oil?

Yes. The pump is designed for oil-free operation and does not require any working medium.

What is the maximum continuous operating time?

The self-cooling air draft system allows 24-hour continuous operation without overheating.

Which models support both vacuum and pressure functions?

VP020 and VP100A support both vacuum and pressure functions. The others are vacuum-only.

What diaphragm material is used, and is it resistant to chemicals?

The diaphragm is made of Nitrile Rubber, which resists corrosion and is suitable for many chemical environments.

Can I use this pump as a backing pump for a turbo molecular pump?

Yes. The pump is designed for use as a backing pump for turbo molecular pumps in laboratory applications.

What is the noise level during operation?

The noise level is below 60 dB, suitable for use in quiet laboratory environments.

Do you offer OEM or private-label options?

Yes. The Microlab OEM division supports private-label branding, custom packaging, and contract manufacturing.

Get A Quote For Vacuum Pump

Tell us the membrane, pore size, diameter and quantity you need, or describe the sample and we will specify it.