Syringe filters, chromatography vials, SPE and biotechnology products are produced according to the ISO 9001 standard system. [email protected] +86-15306778688
Multiple Vacuum Filtration System product photo 1
Multiple Vacuum Filtration System product photo 2Multiple Vacuum Filtration System product photo 3Multiple Vacuum Filtration System product photo 4Multiple Vacuum Filtration System product photo 5Multiple Vacuum Filtration System product photo 6
Lab Filtration Products

Multiple Vacuum Filtration System

The Multiple Vacuum Filtration System is a modular manifold setup designed for simultaneous, efficient filtration of three or six samples using a shared vacuum source. It features a stainless steel manifold with independent control valves per station, allowing selective operation and easy cleaning. The system supports both stainless steel and glass filtration units, enabling compatibility with a range of sample types from microbiological testing to food and environmental analysis. A single glass collection bottle handles effluent from all units, reducing setup complexity and consumable use.

  • Independent valve control per station allows selective filtration without affecting other samples
  • Modular design supports 1, 3, or 6 units on a single manifold, adapting to batch size needs
  • Stainless steel manifold and components resist corrosion and withstand repeated cleaning
  • Shared collection bottle reduces the number of containers needed and simplifies waste handling
Key Benefits

What This Product Gives You

  • Independent valve control per station allows selective filtration without affecting other samples
  • Modular design supports 1, 3, or 6 units on a single manifold, adapting to batch size needs
  • Stainless steel manifold and components resist corrosion and withstand repeated cleaning
  • Shared collection bottle reduces the number of containers needed and simplifies waste handling
  • Filtration units are interchangeable between stainless steel and glass, matching sample compatibility requirements
  • Modular manifold system with 1, 3, or 6 filtration stations
  • Independent control valves per station for selective operation
  • Compatible with 300ml stainless steel or glass filtration units
  • Shared glass collection bottle for all units
  • Two hosepipes included per system for vacuum connection
  • Stainless steel manifold resists corrosion and supports sterilization
  • Filtration units fit standard 300ml funnel size with standard flange interface
  • Designed for low-rate, high-sensitivity filtration of particulates and microorganisms
Where It Is Used

Applications And Buyers

Application Scenarios

  • Performing parallel microbiological testing for E. coli in water and food samples across multiple batches
  • Conducting residue analysis on pharmaceuticals and cosmetics with high throughput and consistent results
  • Filtering multiple beverage samples (e.g. beer, juice) for cold sludge or particulate content in one run
  • Carrying out serial filtration in environmental labs for wastewater or soil extract analysis
  • Supporting contamination testing in pharmaceutical manufacturing with rapid, repeatable filtration

Who It Is For

  • Pharmaceutical QC labs needing to process multiple samples under strict contamination control
  • Food and beverage labs performing routine particulate testing on liquids and semi-solids
  • Environmental testing facilities handling large sample volumes from water and wastewater sources
  • Research labs conducting biochemical or hydrobiological studies requiring parallel sample processing
  • Lab distributors seeking a flexible, scalable filtration system for multiple client applications

Problems It Solves

  • Manual handling of multiple single-funnel setups increases time and risk of cross-contamination
  • Lack of independent valve control forces all samples to run simultaneously or in sequence, reducing flexibility
  • Multiple collection bottles increase waste, storage needs, and cleanup effort
  • Single-use filtration systems become costly at high sample volumes due to repeated consumable purchase
  • Inconsistent filtration rates across samples due to shared vacuum lines without individual regulation
Data

Specifications

Number of Stations1, 3, or 6
Manifold MaterialStainless Steel
Filtration Unit Capacity300 ml
Filtration Unit MaterialStainless Steel or Glass
Collection BottleOne 300ml Glass Bottle
Hosepipes IncludedTwo pieces
Valve TypeIndependent control per station
Vacuum SourceShared, external vacuum pump
CompatibilityStandard 300ml funnel flange interface

Materials

  • Stainless steel manifold and filtration units
  • Glass collection bottle
  • Glass funnel (300ml)
  • Stainless steel funnel (300ml)
  • Hosepipes for vacuum connection

Customization Options

  • OEM private-label printing available through the Microlab OEM division
  • Custom manifold configurations (e.g. non-standard station counts) on request
  • Alternative hose length or material (e.g. silicone) upon specification
  • Custom packaging and labeling for distributor or lab branding
  • Supply of individual components (e.g. single manifold, glass funnel) for replacement
How It Is Made

Manufacturing And Quality Control

Manufacturing Process

  • Stainless steel manifold fabrication using precision machining
  • Die-cutting and assembly of glass and stainless steel filtration units
  • Integration of independent control valves into the manifold
  • Testing of vacuum integrity and flow balance across all stations
  • Packaging with hosepipes and clear labeling of system configuration

Quality Control

  • Manifold and valve assembly inspected for leaks under vacuum
  • Filtration units tested for dimensional consistency with standard 300ml flange
  • Glass components checked for cracks or surface defects before packing
  • Hosepipes verified for correct length and compatibility with standard fittings
  • System configuration verified against order (e.g. MVF0103S vs MVF0106G)
Comparison

Compared With The Alternatives

Versus Single-funnel vacuum filtration

The multiple system reduces labor and setup time by allowing parallel processing, while maintaining independent control per sample

Versus Disposable multi-channel filtration systems

This system is reusable and reduces long-term consumable cost, though it requires cleaning between runs

Versus Shared vacuum manifold with no individual valves

Independent valves allow selective operation, enabling partial runs and easier disinfection

Versus Glass manifold systems

Stainless steel manifold offers better durability and resistance to mechanical stress during cleaning and reuse

Versus Integrated filtration benches

This modular system is more flexible and scalable, allowing labs to expand capacity incrementally without full system replacement

Use Guide

How To Use It

  • Select the manifold configuration (MVF0101S, MVF0103S, etc.) based on the number of samples to process
  • Attach the filtration units to the manifold using the flange interface; ensure seals are intact
  • Connect the vacuum hose to the manifold inlet and the collection bottle to the outlet
  • Open the control valve for each station only when ready to start filtration
  • Monitor flow rate and pressure; adjust vacuum level if one station blocks early
  • After use, disconnect units, clean with appropriate solvent or detergent, and dry before storage
  • Replace glass components if cracked or chipped; inspect seals regularly
Photos

Product Gallery

Also In This Category

Related Products

Read Next

Related Industries And Guides

FAQ

Questions Buyers Ask

Can I use this system for microbiological testing?

Yes. The system is suitable for microbiological QC, including E. coli detection, when used with sterile filtration units and proper aseptic technique.

What is the difference between the stainless steel and glass filtration units?

Stainless steel units are more durable and resistant to impact; glass units are chemically inert and suitable for sensitive analyses where metal leaching is a concern.

How many samples can I run at once?

The system supports 1, 3, or 6 samples simultaneously, depending on the manifold model selected (MVF0101S, MVF0103S, MVF0106S, etc.).

Can I use a different size collection bottle?

The system is designed for a single 300ml glass bottle. Using a different size may affect vacuum balance and drainage efficiency.

Is the manifold compatible with standard vacuum pumps?

Yes. The manifold uses standard fittings and connects to any vacuum source with a compatible hose connection.

Can I buy individual components like a single funnel or manifold?

Yes. Individual components such as the MVFF300G (glass funnel) or MVFSM03 (manifold for three units) are available for replacement or expansion.

Do you offer private-label options?

Yes. The Microlab OEM division supports private-label printing, custom packaging, and component sourcing for distributors and lab brands.

Get A Quote For Multiple Vacuum Filtration System

Tell us the membrane, pore size, diameter and quantity you need, or describe the sample and we will specify it.