Glass Insulators
Toughened glass disc insulators from 40 kN to 550 kN for 10 kV to 500 kV AC and DC lines.
Why This Profile Exists
Porcelain hides its own faults. A failed toughened glass shell shatters and leaves the cap and pin in place, so a line crew can spot a zero-value unit from the ground or from a helicopter.
Load classes in this category run from 40 kN to 550 kN.

PSD70E 70kN EMS Anti Fog Type Corrosion Proof Disc Insulator Glass Type
View specifications →
PSV160A 160kN EMS Anti Fog Type Corrosion Proof Disc Insulator Glass Type
View specifications →
PSV120B 120kN EMS Anti Fog Type Corrosion Proof Disc Insulator Glass Type
View specifications →
PSD70E 70kN EMS Anti Fog Type Corrosion Proof Disc Insulator Glass Type Type TYPE
View specifications →
U70BL High Voltage 70 KN Electrical Glass Insulator
View specifications →
PS70E 70kN EMS Anti Fog Type Corrosion Proof Disc Insulator Glass Type
View specifications →
PSV70A High Voltage 70 KN Electrical Glass Insulator
View specifications →
U40B 11kV CTV 175 HV 40 KN Glass Electric Insulator
View specifications →
U160BLP 400kV HV AC 160kN Fog Type Glass Suspension Insulator
View specifications →
U160B 220kV HV AC Electric Line Glass Insulator
View specifications →
U120B 66kv Anti-pollution Toughened Glass Insulator
View specifications →
U40BP High Voltage Power Line Toughened Glass Insulator
View specifications →
High Voltage Disc Type Suspension Insulators PSV160A in Transmission Line
View specifications →
U40B 33kV CTV 254 HV 40 KN Glass Electric Insulator
View specifications →
U100BLP 100kN Anti-fog Disc Suspension Glass Insulator
View specifications →
U100BP/146D Double-wing Anti-pollution Disc Toughened Glass Insulator
View specifications →
U70BLD/U70BSD UHV AC 70kN Disk Suspension Toughened Glass Insulator
View specifications →
U160BP/155M 400kV HV160kN Aerodynamic Disc Suspension Glass Insulator
View specifications →
U160BP/146M 400kV AC 160kN Air-dynamic Disc Suspension Glass Insulator
View specifications →
U160BP/155M 160kN Aerodynamic Toughened Glass Insulator
View specifications →
U120BP/127M UHV AC 120kN Aerodynamic Toughened Glass Insulators
View specifications →
U40BP 11 CTV 254 High Voltage Suspension 40 Kn Electrical Glass Insulator
View specifications →
U40B High Voltage Suspension 40 KN Toughened Glass Insulator
View specifications →
U70BL 16 254 110kV Power Lines 70 KN Electrical Glass Insulator
View specifications →
U40B 11 CTV 175 High Voltage Suspension 40 KN Toughened Glass Insulator
View specifications →
U70B High Voltage Earth Wire 70kN Toughened Disc
View specifications →
U70CN Earth Wire Disc Suspension 70 KN Toughened Glass Insulator
View specifications →
U100C High Voltage Earth Wire 100 KN Toughened Glass Insulator
View specifications →
U100CN High Voltage Earth Wire 100 KN Toughened Glass Insulator
View specifications →
U40B Standard Type U40B Toughened Glass Suspension Insulator
View specifications →
U70BL High Voltage Suspension 70 Kn Electrical Glass Insulator
View specifications →
70kN U70BS Glass Insulator IEC Standard for Transmission Lines
View specifications →
U100B 100kN High Strength Glass Insulator
View specifications →
U100BS High Voltage Suspension 100 KN Toughened Glass Insulator
View specifications →
U120B IEC Standard High Strength Glass Insulator for 110kV 220kV Lines
View specifications →
U120B HV DC Standard Profile Power Line Glass Insulator
View specifications →
U160B IEC Standard Glass Insulator for 220kV 500kV
View specifications →
U160BL HV AC Disc Type Suspension Tempered Glass Insulator
View specifications →
U210BL 210kN UHV AC Suspension Glass Insulator
View specifications →
U240B 240kN Insulators Suspension Electrical Glass Insulator
View specifications →
U300B 300kN UHV AC Suspension Electrical Glass Insulator
View specifications →
420kN U420B Suspension Electrical Glass Insulator for Power Line
View specifications →
550kN U550B Ultra High Voltage Toughened Glass Insulator
View specifications →
U70BLP 70kN Anti-Fog Anti-Pollution Toughened Glass Insulator
View specifications →
U70BP 110kV Anti-pollution AC Suspension Toughened Glass Insulator
View specifications →
U100BP 100kN Anti-Pollution Fog Type Toughened Glass Suspension Insulator
View specifications →
U100BP 500kV EHV Suspension 100 KN Toughened Glass Insulator
View specifications →
U120BP 120kN Anti-Pollution Fog Type Toughened Glass Suspension Insulator
View specifications →
U120BP-1 High Voltage Suspension 120 KN Electrical Glass Insulator
View specifications →
U160BLP 800KV UHVDC 160KN IEC Standard Anti-pollution Glass Suspension Insulator
View specifications →
U160BP/155 UHV AC 1000kV Disc Type Suspension Tempered Glass Insulator
View specifications →
U160BP 110KV 220kV160KN Anti-pollution Glass Suspension Insulator
View specifications →
U160BSP 750kV HV Disc Type Suspension Tempered Glass Insulator
View specifications →
U160BSP UHV AC High Voltage Anti-pollution Toughened Glass Insulators
View specifications →
U210BP 210kN UHV AC Suspension Glass Insulator
View specifications →
U240BP 240kN Fog Type Anti-Pollution Toughened Glass Suspension Insulator
View specifications →
300kV 500kV UHV DC U300BP Stain-resistant Suspension Electrical Glass Insulator
View specifications →
UHV DC 500kV 420kN U420B Stain-resistant Suspension Electrical Glass Insulator
View specifications →
Power Grid UHV DC 550kN U550BP Stain-resistant Disc Suspension Electrical Glass Insulator
View specifications →
U70BP/146M 70kN Aerodynamic Toughened Glass Suspension Insulator
View specifications →
100kN U100BP/146M Anti-Pollution Suspension Glass Insulator for Transmission Line
View specifications →
LXAP-120 / U120BP 120kN Aerodynamic Glass Insulator
View specifications →
LXAP-160 / U160BP 160kN Aerodynamic Glass Insulator
View specifications →
LXAP-210 / U210BP 210kN Aerodynamic Glass Insulator
View specifications →
LXAP-240 / U240BP/170M 240kN Aerodynamic Glass Insulator
View specifications →
Double-shed Disk Suspension Toughened Glass Insulator UG70B146/450D/16R
View specifications →
100kN U100BLD / PSD-100E Double Shed Toughened Glass Suspension Insulator
View specifications →
UHV AC 120kN U120BLD / PSD-120E Two-Wing Anti-Pollution Tempered Glass Disc Insulator
View specifications →
AC U160BLD 160kN Double Shed Toughened Glass Suspension Insulator
View specifications →
UHV DC 220kV 500kV 210kN U210BLD Double-umbrella Suspension Electrical Glass Insulator
View specifications →
220kV 500kV High Voltage 300kN Double-umbrella Electrical Glass Insulator
View specifications →Where This Category Gets Specified
Pressed Tempered And Load Tested In Our Own Plant
Raw material screening, automatic batching, melting, pressing, uniform tempering, cold and hot impact, homogenisation, cementing, curing, inspection and packing - all on one site.
German And Italian Lines
Production and testing equipment imported from Germany and Italy feeds two modern lines.
6 Million Pieces A Year
One natural-gas electric melting kiln with about 50 m² of melting area.
Routine Load Test On Every Piece
A piece that breaks is removed and the cause traced through the process record.
Type Test Reports
Reports from XIHARI and the National Ceramic Product Quality Inspection and Testing Center.
Guides That Touch This Category
Glass Insulators Questions
Straight answers to the questions buyers ask before a first order.
Which line conditions suit glass insulators?
Porcelain hides its own faults. A failed toughened glass shell shatters and leaves the cap and pin in place, so a line crew can spot a zero-value unit from the ground or from a helicopter.
What is the load range in this category?
Load classes in this category run from 40 kN to 550 kN.
Are dimensional drawings available?
Yes. PDF drawings for the common types are on the downloads page, and a drawing for any listed type can be issued on request before you place an order.
How are these packed for export?
Units are packed in wooden crates built for sea freight. Crate contents and weights are confirmed on the packing list issued with the shipping documents.
Can the goods be inspected before shipment?
Yes. Buyers are welcome at the plant, and third-party inspection by Intertek, BV or SGS can be appointed by the buyer.
Need A Type List For Glass Insulators?
Send the line voltage, the specified failing load and the pollution class. We will match the type codes and send the drawings.