GreatWall KWD-808I Electronic Acupuncture Stimulator

The GreatWall KWD-808I is a microcomputer electronic acupuncture stimulator designed for acupoint detection, electro-needle therapy, TENS massage, and magneto-therapy in clinical...

Product Overview

What the GreatWall KWD-808I Is Built To Do

The GreatWall KWD-808I is a microcomputer electronic acupuncture stimulator designed for acupoint detection, electro-needle therapy, TENS massage, and magneto-therapy in clinical treatment rooms. Equipped with 6 output channels and 2 detection jacks, the unit delivers 5 selectable waveforms with illuminated indicators and operates on either AC 110V or 6 C-size batteries. A built-in voltmeter, music timing switch, and error warning tone allow clinical staff to administer multi-point needle stimulation and pulse electric therapy with controlled output.

At A Glance
  • Model: KDW-808I (KWD-808I)
  • Brand: Huayan Medical
  • Output channels: 6
  • Acupoint detection outputs: 2
  • Wave forms: 5 types (Continuous, Intermittent, Ripple, Respiration, Auto-cycle)
  • Supply voltage: AC 110 V, DC 9 V
Key Benefits

Why Buyers Specify the GreatWall KWD-808I

  • Six output channels allow multi-point electro-needle therapy or surface stimulation across several anatomical zones at once
  • Two dedicated detection jacks work with the detection pen to locate electrical acupoints before starting stimulation
  • Five selectable waveforms provide continuous, intermittent, ripple, respiration, and auto-cycling pulse currents for varied clinical protocols
  • Dual power architecture runs on 110V AC or six C-size batteries for portable use between ward beds
  • Audio error tone and built-in music timing switches alert practitioners to operational faults or elapsed session times
  • Low power consumption under 5W keeps operating costs low and preserves battery life during mobile treatments
Problems It Solves
  • Manual needle twirling is labour-intensive and produces inconsistent stimulation frequency over long treatment sessions
  • Separate detection devices and stimulators crowd clinic cart surfaces and require dual maintenance
  • Single-output or dual-output stimulators require multiple machines to treat complex multi-point prescription plans
  • Absence of operational error warnings can leave lead disconnections or circuit errors unnoticed during unattended sessions
  • Mains-only devices cannot be moved easily between clinic treatment cubicles or mobile care settings
Where It Is Used

Where the GreatWall KWD-808I Is Used

Application Scenarios
  • TCM hospital outpatient departments applying multi-needle electro-acupuncture for pain relief and meridian treatment
  • Acupuncture wards in general hospitals administering prolonged pulse electric stimulation without continuous manual manipulation
  • Rehabilitation centres treating muscle and joint stiffness caused by fatigue or sustained physical work
  • Private TCM clinics delivering needle-less acupoint pulse therapy and TENS massage to sensitive patients
  • TCM health centres providing circulation enhancement and fatigue recovery protocols across scheduled patient appointments
Who It Is For
  • TCM hospital clinical department heads equipping acupuncture and physical therapy treatment cubicles
  • Private acupuncture clinic practitioners needing reliable multi-lead electro-needle and point-detection equipment
  • Rehabilitation centre directors adding electronic meridian stimulation to physical therapy programmes
  • Medical equipment distributors supplying registered TCM devices to overseas hospitals and clinics
Technical Features

Inside the GreatWall KWD-808I

  • Microcomputer-controlled pulse electric output across 6 independent channel jacks
  • Two dedicated acupoint detection output circuits linked to a handheld detection pen
  • Five distinct pulse waveforms including continuous wave, intermittent wave, ripple wave, respiration wave, and auto-cycling output
  • Illuminated panel symbols displaying the active waveform selection during operation
  • Integrated treatment timer with music sound alerts and onboard voltmeter readout
  • Dual-source power system supporting 110V AC line power or 9V DC battery power
  • Standard rectangular female connector ports with locking stability for treatment leads
  • Audible error tone alerting staff when improper circuit or operating conditions occur
Materials and Build
  • Moulded housing available in grey or black finish for benchtop clinical deployment
  • Conductive electropads supplied with dual lead wires for transcutaneous surface stimulation
  • Insulated lead wires terminating in alligator clips for firm needle contact during electro-acupuncture
  • Handheld detection pen probe for locating anatomical skin conduction points
Specifications

GreatWall KWD-808I Electronic Acupuncture Stimulator Technical Data

Figures below are taken from the manufacturer data sheet for this model. Tell us your local voltage and dosing practice and we will confirm the build before the order.

ModelKDW-808I (KWD-808I)
BrandHuayan Medical
Output channels6
Acupoint detection outputs2
Wave forms5 types (Continuous, Intermittent, Ripple, Respiration, Auto-cycle)
Supply voltageAC 110 V, DC 9 V
Battery requirement6 C-size batteries (1.5 V x 6 / CR14 / UM2)
Input power<= 4 VA
Maximum power consumption< 5 W
Dimensions222 mm x 172 mm x 75 mm
Plug typeRectangular female
Error toneTone (song) sounds on error
Available housing coloursGrey, black
How It Is Made and Checked

How the GreatWall KWD-808I Is Built and Checked

How This Model Is Built and Tested
  • Connect the unit to a 110V AC supply or install six C-size batteries into the rear compartment
  • Plug the detection pen into a detection jack to locate target acupoints along the meridian
  • Insert rectangular female lead plugs into the required output channels among the six available
  • Attach alligator clips to inserted acupuncture needles or affix electropads to target muscle areas
  • Select the required waveform from the five options and observe the lit indicator symbol
  • Set treatment duration with the music timing switch and gradually increase channel intensity
  • Conclude the session when the music timer sounds, turn intensity dials to zero, and disconnect leads
Quality Control
  • Channel output voltages and waveform consistency verified prior to factory packaging
  • Audible error tone and music timing switches tested under simulated open-circuit conditions
  • Battery compartment and AC power input circuits checked for stable DC conversion
  • Manufacturing facility operates under ISO 9001 and ISO 13485 medical device quality systems
  • CE certified for compliance with relevant international medical equipment directives
Certification Held By The Plant
ISO 9001ISO 13485CE markingTested as a complete cycle before packing
Customization

Building the GreatWall KWD-808I To Your Practice

  • Grey or black outer casing options selected at time of procurement
  • Power input configured for AC 110V adapter or battery-powered standalone use
  • Compatible with direct replacement accessories including extra electropads, lead wires, and alligator clips
Use Guide
  • Place the device on a stable horizontal surface in the treatment room away from moisture
  • Select battery power using 6 C-size cells or plug the unit into a 110V AC socket
  • Confirm that all output dials are set to zero before connecting patient leads
  • Use the detection pen to identify target stimulation points on the skin surface
  • Connect up to six alligator clip leads to placed acupuncture needles or apply electropads
  • Choose among continuous, intermittent, ripple, respiration, or auto-cycling wave outputs
  • Monitor the onboard voltmeter and lit wave indicators during the treatment cycle
  • Switch off the power switch and wipe down cables and exterior panels with clinical disinfectant after use
Comparison

How the GreatWall KWD-808I Compares

An honest read on where this model wins and where another one suits you better.

vs Manual needle manipulation
The KWD-808I delivers continuous, steady waveform frequencies across six needle pairs without manual practitioner fatigue, though it requires lead wire attachment
vs Standard 2-channel TENS units
The KWD-808I provides 6 output channels and dedicated acupoint detection jacks, requiring a larger benchtop footprint of 222 mm by 172 mm
Questions Buyers Ask

GreatWall KWD-808I Questions and Answers

How many outputs does the KWD-808I provide for simultaneous treatment?
The device features 6 independent stimulation output channels and 2 separate acupoint detection output jacks.
What power supplies can be used to run the stimulator?
It operates on 110V AC line power or on 9V DC power using 6 C-size batteries (CR14/UM2).
What accessories are included with the unit?
The package includes 4 electropads with 2 lead wires, 1 acupoint detection pen, and 6 alligator clip output wires.
What is the typical production and delivery lead time?
Standard orders generally ship about 6 days after payment is received, depending on model quantity.
What happens if an operational fault or connection error occurs?
The KWD-808I features a built-in error alert system where a specific tone or song sounds to notify the operator.
What warranty terms apply to this equipment?
Huayan Medical provides a one-year free warranty from qualified commissioning, with faulty parts replaced free of charge.