Shock Wave Therapy Device RH-CJB-A
The RH-CJB-A is a radial shock wave therapy device designed for physiotherapy, joint rehabilitation, and pain management in clinical settings.
What the RH-CJB-A Is Built To Do
The RH-CJB-A is a radial shock wave therapy device designed for physiotherapy, joint rehabilitation, and pain management in clinical settings. It generates high-energy acoustic waves that radiate through the skin surface to reach internal pain sites in the shoulder, back, heel, knee, or elbow. Built for TCM hospitals, clinics, and rehabilitation centres treating chronic musculoskeletal conditions, the compact unit combines an LED display with keystroke operation and four selectable pulse treatment modes. The shock gun incorporates an internal anti-rattler spring to limit vibration kickback to the therapist, and the unit comes equipped with 15 mm ESWT, 20 mm RSWT, trigger transmitters, and four acupuncture conduction terminals.



Why Buyers Specify the RH-CJB-A
- Four pulse frequency modes provide single, three, five, or ten shocks per second to match therapy plans
- Shock gun includes an internal anti-rattler spring to preclude operator fatigue and vibration side effects
- Non-invasive acoustic energy reaches deep tissue without surgical intervention, anesthesia, or downtime
- Standard package includes 20 mm RSWT and 15 mm ESWT heads plus four acupuncture conduction terminals
- Dedicated software gives fast access to an extensive stored protocol list with proposed parameters
- Compact and modern chassis with simple keystroke controls enables easy relocation between therapy rooms
- Hand fatigue and vibration strain experienced by operators running multiple shock wave sessions daily
- Patient downtime and infection risks linked to surgical options or needle-based invasive procedures
- Trial-and-error treatment setup resolved through dedicated storage software and proposed parameters
- Inability to adapt acoustic shock focus across different anatomical areas without changing transmitter heads
- Patient discomfort during conservative pain treatments requiring anesthesia or prolonged recovery periods
- Lack of specialized conduction tips for applying shock wave acoustic therapy directly to acupuncture points
Where the RH-CJB-A Is Used
Inside the RH-CJB-A
- Radial shock wave emission mechanism radiating high-energy acoustic waves through the skin surface
- Shock gun fitted with an anti-rattler spring to minimize physical side effects to the operator
- LED display paired with responsive keystroke parameter operation
- Four pulse frequency modes: Single (1 shock/sec), Slow (3 shocks/sec), Middle (5 shocks/sec), Fast (10 shocks/sec)
- Automatic shutdown function stops acoustic emission once the selected mode run time finishes
- Dedicated internal software storing comprehensive therapy protocol lists and suggested treatment parameters
- Standard configuration with RSWT 20 mm and ESWT 15 mm transmitters
- Dedicated ESWT trigger device transmitter for targeted therapy
- Four acupuncture conduction terminals for integration with meridian point treatment
- Ergonomic applicator housing designed to support multiple handling positions during manual therapy
Shock Wave Therapy Device RH-CJB-A Technical Data
Figures below are taken from the manufacturer data sheet for this model. Tell us your local voltage and dosing practice and we will confirm the build before the order.
| Model | RH-CJB-A |
|---|---|
| Brand | Huayan Medical |
| Product category | Shock Wave Therapy Device |
| Display | LED display |
| Operation interface | Keystroke operation |
| Pulse mode Single | 1 shock per second |
| Run timer control | Automatic stop when selected mode time ends |
| Standard transmitters | RSWT 20 mm, ESWT 15 mm, trigger device transmitter |
| Applicator protection | Anti-rattler spring in shock gun |
How the RH-CJB-A Is Built and Checked
- Switch on the unit and select treatment parameters via the front LED display and keystroke interface
- Choose a stored protocol from the internal software list or set custom therapy parameters
- Attach the appropriate transmitter head or acupuncture conduction terminal to the shock gun
- Apply acoustic wave energy to the target treatment area across the shoulder, back, heel, knee, or elbow
- Run selected pulse frequency mode from single shock up to ten shocks per second
- Unit automatically cuts off shock generation when the scheduled treatment mode time elapses
- Shock gun mechanism and anti-rattler spring tested for stable mechanical acoustic output
- Pulse timing accuracy and automatic shut-off cycle verified on each operating mode before shipping
- Manufactured under certified ISO 9001 and ISO 13485 medical device quality management systems
- Carries CE marking for compliance with regulatory standards for exported equipment
- Every device undergoes factory electrical and keystroke function inspection prior to packing
Building the RH-CJB-A To Your Practice
- Supplied with language-specific English control labels and English operating documentation
- Flexible transmitter head combinations to meet specialized clinical protocol requirements
- Distributor supply arrangements available for dedicated physical therapy brand channels overseas
- Compatible with clinical facility accessories and multi-unit overseas project shipments
How the RH-CJB-A Compares
An honest read on where this model wins and where another one suits you better.
Industries Using the RH-CJB-A
Rehabilitation and Physiotherapy Centres
Rehabilitation departments adding fumigation, moxibustion, shock wave and wax therapy to existing treatment rooms.
TCM Clinics and Acupuncture Practices
Clinic owners with one dispensary corner and one member of staff, who still want patients leaving with pouches.
Distributors and Importers of TCM Equipment
Importers and agents who need a full range, English documentation and parts support so they can service what they sell.
RH-CJB-A Questions and Answers
What clinical indications is the RH-CJB-A shock wave device used for?
What pulse frequencies can be set on the RH-CJB-A?
What transmitter attachments come in the standard configuration?
What quality certifications cover the manufacturing of this device?
What is the typical production lead time after payment?
What warranty and spare parts terms apply to overseas buyers?
Other Models Worth Comparing




Guides That Help You Decide
Importing TCM Equipment Lead Time Payment and Support
Importing clinical TCM machinery begins by translating clinical prescription volume into machine specifications.
Buying GuideChoosing a Moxibustion Therapy Device
Selecting between the RH-K-GJ models depends on whether your clinic requires wormwood fumigation alongside electro-optical...
Product GuideTCM Fumigation Therapy Equipment Guide
TCM fumigation combines thermal heating with herbal steam therapy to treat localized pain points and systemic conditions.
Ready to price the RH-CJB-A
Send us your local voltage, your session volume and the space you have. A price and a full specification sheet for the RH-CJB-A come back within twelve hours.