XK3190-A12 Weighing Indicator
High resolution indicator with anti-vibration software for platform and floor scales.

Product Overview
The XK3190-A12 family is built around fast, high precision analogue to digital conversion with a readability of 1 in 30000 and software written to reject vibration. It is intended for platform scales, floor scales and weighing systems using one to four load cells, and is available with an LCD or LED display.
| Models | A12, A12S, A12E, A12ES |
|---|---|
| Input signal range | -10 mV to 15 mV |
| Input sensitivity | 1 microvolt per division |
| Load cell excitation | 5 V DC at 150 mA |
| Maximum load cell connection | 4 at 350 ohm |
| Display | 6 bit LCD or 6 bit LED with 6 status indications |
| Interface | RS232C serial communication, optional |
| Transmission distance | RS232C up to 30 metres |
Category: Weighing Indicators
Key Benefits
- A/D conversion with 1 in 30000 readability for fine division work
- Anti-vibration software for benches near moving machinery
- Counting function with data retained if power is lost
- LCD and LED display variants under one model family
Problems It Solves
- Readings that will not settle on a shop floor
- Counting data lost when power fails
- Coarse resolution limiting the division a scale can display
Who It Is For
- Platform and floor scale manufacturers
- Plants weighing near vibrating equipment
- Builders needing a fixed value output for simple control
Application Scenarios
- Floor scale on a production floor with vibration
- Counting station where the count must survive a power cut
- Platform scale with one to four load cells
Technical Features
- A/D conversion with readability 1 in 30000
- Anti-vibration software with settable digital filter intensity, range and stable time
- Zero tracking and zero range setup, automatic or manual
- Counting function with unit data save protection on power off
- Optional kg and lb switching, animal scale function and two fixed value TTL outputs
Full Specification Data
These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.
| Model | A12 / A12S | A12E / A12ES |
| Input signal range | -10mV~ 15mV | |
| Input sensitivity | 1 V/e | |
| Load cell Excitation | Dc 5V :/ 150mA | |
| Max. load cell connection | 4 at 350 ohm | |
| Display | 6 bits LCD, 6 status indications | 6 bits LED, 6 status indication |
| Optional interface | RS232C serial communication | |
| Transmission distance | RS232C 30 meters | |
Materials And Construction
- Plastic housing
Customisation Options
- LCD or LED display variant
- Animal scale function on A12 and A12S
- Two fixed value TTL outputs as an option
Use Guide
- Tune digital filter intensity and stable time to the vibration actually present rather than to maximum
- Keep RS232C cable runs within 30 metres
- Use the internal code display to analyse tolerance rather than judging by the weight reading alone
How It Compares
| XK315A1 indicator | The XK315A1 is the simpler general purpose head with a wider standard function list. The A12 focuses on high resolution conversion and vibration rejection. |
|---|---|
| XK3101 control indicator | For real batching control with fieldbus and multiple on-off outputs, the XK3101 is the correct head. The A12 offers two fixed value outputs only. |
Often Ordered With This Model

XK315A1 Weighing Indicator
General purpose plastic housing indicator with red LED display, RS232 and 30 hour battery.
View specifications →
XK3118T6-P Printing Weighing Indicator
Platform scale indicator with a built in 57 mm thermal printer and real time clock.
View specifications →
XK3101 Weighing Control Indicator
Panel mount control indicator with fieldbus interfaces and batching outputs for control cabinets.
View specifications →How To Choose A Weighing Indicator
Indicators are bought by part number and regretted by function. Decide what the head has to do on site first, then check it can drive your cells.
How To Choose Load Cell Capacity And Accuracy Class
Capacity and accuracy class are the two numbers that decide whether a scale can be built and verified. Here is how to derive both before you commit to a design.
XK3190-A12 Weighing Indicator Questions
What resolution does the A12 offer?
A/D conversion with a readability of 1 in 30000.
How many load cells can it drive?
Up to four at 350 ohm, with 5 V DC 150 mA excitation.
Which variants support animal weighing?
The animal scale function is listed for the A12 and A12S.
Get A Quotation For The XK3190-A12 Weighing Indicator
Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.