Syringe filters, chromatography vials, SPE and biotechnology products are produced according to the ISO 9001 standard system. [email protected] +86-15306778688
Vent Filter product photo 1
Vent Filter product photo 2Vent Filter product photo 3Vent Filter product photo 4Vent Filter product photo 5Vent Filter product photo 6
Syringe Filter

Vent Filter

The 50mm Vent Filter is designed for venting and liquid filtration in bioreactors, fermenters, and sterile processing systems. It removes microorganisms, particles, precipitates, and undissolved powders larger than the nominal pore size of 0.22 or 0.45 micron. The filter features a low hold-up volume and minimal particle shedding, making it suitable for critical applications in pharmaceutical and biotechnology processes.

  • 50mm diameter provides large surface area for high throughput and increased air flow rates
  • Thermal bonding sealing without adhesives reduces extractables and maintains integrity during sterilization
  • Reusable and autoclavable up to three cycles of 30 minutes at 123℃, supporting repeated use in sterile processes
  • Low hold-up volume minimizes sample loss and product carry-over in sensitive bioprocesses
Key Benefits

What This Product Gives You

  • 50mm diameter provides large surface area for high throughput and increased air flow rates
  • Thermal bonding sealing without adhesives reduces extractables and maintains integrity during sterilization
  • Reusable and autoclavable up to three cycles of 30 minutes at 123℃, supporting repeated use in sterile processes
  • Low hold-up volume minimizes sample loss and product carry-over in sensitive bioprocesses
  • Minimal particle shedding ensures clean filtrate, reducing contamination risk in sterile environments
  • Five membrane options: Nylon, PTFE, Hydrophilic PTFE, CA, PES, PVDF, Hydrophilic PVDF
  • Diameter of 50 mm with filtration area ≥0.021 cm²
  • Pore sizes of 0.22 and 0.45 micron available
  • Stepped hose barb inlet (7-13 mm) with 6:100 luer slip outlet for flexible connection
  • Maximum operating pressure: 3.5 bar at 23℃ for liquids, 3 bar at 23℃ for air/gas; 3.0 bar at 60℃ for liquids, 2.5 bar at 60℃ for air/gas
  • Sterilized by EO or three autoclave cycles of 30 minutes at 123℃
Where It Is Used

Applications And Buyers

Application Scenarios

  • Venting bioreactors and fermenters during sterile culture processes
  • Filtering air and gas streams in sterile processing lines to prevent microbial ingress
  • Sterilizing liquid feeds before introduction into closed bioprocess systems
  • Removing particulates and microorganisms from buffer solutions in biotechnology workflows
  • Supporting reusable filtration in high-volume bioprocessing where cost and consistency matter

Who It Is For

  • Pharmaceutical and biotechnology laboratories requiring sterile filtration in bioreactor systems
  • Bioprocessing teams using reusable filtration components in fermenter vent lines
  • R&D labs developing sterile cell culture and fermentation protocols
  • Contract manufacturers running high-throughput sterile processes with strict contamination control
  • Lab distributors sourcing reusable, autoclavable filters with broad chemical resistance

Problems It Solves

  • Microbial contamination entering bioreactors through unfiltered vent lines
  • High hold-up volume in filters causing product loss in small-scale bioprocesses
  • Particle shedding from filters contaminating sensitive cell cultures or protein solutions
  • Frequent filter replacement due to poor reusability in sterile environments
Data

Specifications

Filter MediaNylon, PTFE, Hydrophilic PTFE, CA, PES, PVDF, Hydrophilic PVDF
HousingPP
Diameter50 mm
Filtration Area≥0.021 cm²
Pore Size0.22, 0.45 micron
Sealing TechnologyThermal bonding, No adhesives
Inlet/Outlet7-13 mm stepped hose barb with 6:100 luer slip
Max Operating Pressure3.5 bar at 23 C (liquid), 3.0 bar at 60 C (liquid), 3.0 bar at 23 C (air/gas), 2.5 bar at 60 C (air/gas)
SterilizationEO or 3 autoclave cycles of 30 min at 123℃
Packing25 pcs per pack

Materials

  • Membrane selected per application: Nylon, PTFE, Hydrophilic PTFE, CA, PES, PVDF, Hydrophilic PVDF

Customization Options

  • OEM printing and private-label packing through the Microlab OEM division
  • OEM contract manufacturing and membrane die-cut and packing for filter brands
  • Part number selection based on membrane type, pore size, and packing
How It Is Made

Manufacturing And Quality Control

Manufacturing Process

  • Membrane die cutting to size
  • Connection port formation with stepped hose barb and luer slip
  • Sterilization by EO or three autoclave cycles of 30 minutes at 123℃
  • Packing at 25 pieces per pack

Quality Control

  • Membrane and housing inspected before assembly
  • Sealing integrity tested under maximum operating pressure
  • Pore size and membrane type verified against part number
  • Sterilization validation performed per EO or autoclave cycle specification
Comparison

Compared With The Alternatives

Versus Solvent-bonded filters

Thermal bonding eliminates adhesive in the flow path, reducing extractables and improving compatibility with sensitive bioprocesses

Versus Single-use vent filters

Reusable design supports multiple autoclave cycles, reducing consumable cost over time in high-volume bioprocessing

Versus Smaller diameter filters

50mm diameter provides larger filtration area and higher throughput, reducing pressure drop during high air flow

Versus Filters with adhesive seals

No adhesives used in sealing ensures no leaching during repeated sterilization, maintaining filter integrity

Use Guide

How To Use It

  • Select membrane based on fluid compatibility: PTFE and PVDF for aggressive solvents, PES and CA for aqueous solutions, Nylon for mixed phases
  • Use 0.22 micron for sterilizing filtration of liquids and gases, 0.45 micron for particulate removal in non-sterile applications
  • Connect the stepped hose barb (7-13 mm) to tubing and ensure a secure fit before use
  • Sterilize by EO or three autoclave cycles of 30 minutes at 123℃ before first use and after each cycle
  • Do not exceed 3.5 bar at 23℃ for liquids or 3.0 bar at 60℃; monitor pressure during operation
Photos

Product Gallery

Also In This Category

Related Products

Read Next

Related Industries And Guides

FAQ

Questions Buyers Ask

What membranes are available for the 50mm Vent Filter?

Available membranes are Nylon, PTFE, Hydrophilic PTFE, CA, PES, PVDF, and Hydrophilic PVDF

What is the maximum operating pressure?

For liquids: 3.5 bar at 23℃ and 3.0 bar at 60℃. For air and gas: 3.0 bar at 23℃ and 2.5 bar at 60℃

How is the filter sealed?

The filter uses thermal bonding with no adhesives, which reduces extractables and improves compatibility with sterile processes

What is the packing quantity?

Each pack contains 25 pieces. Part numbers are assigned per membrane type and pore size

Can I get these under my own brand?

Yes. The Microlab OEM division offers private-label printing and packing, OEM contract manufacturing, and membrane die-cut and packing

Get A Quote For Vent Filter

Tell us the membrane, pore size, diameter and quantity you need, or describe the sample and we will specify it.