Zhengzhou, China Laboratory thermal processing since 2008 ISO 9001 & CE compliant
ZYLAB laboratory furnace interior

Ultrasonic Atomization CVD Furnace

This Ultrasonic Atomization CVD Furnace is an Aerosol-Assisted Chemical Vapor Deposition (AACVD) system (using liquid/gas aerosol precursors to grow on substrates), designed for applications such as fuel cells and ZnO transparent conductive films. It consists of three main modules: a microflow liquid high-precision...

Ultrasonic Atomization CVD Furnace

Overview

This Ultrasonic Atomization CVD Furnace is an Aerosol-Assisted Chemical Vapor Deposition (AACVD) system (using liquid/gas aerosol precursors to grow on substrates), designed for applications such as fuel cells and ZnO transparent conductive films. It consists of three main modules: a microflow liquid high-precision delivery system, an ultrasonic atomization system, and a tube furnace with a maximum temperature of 1200°C. This technology is suitable for using non-volatile precursors and can be widely applied in the preparation of nanomaterials, electrode material coating, and composite materials.

Main Features

  • Liquid Flow Control System: High-precision delivery of intermediates, microflow liquid delivery; flow range: 0.04 to 36 ml/min.
  • Atomization Device: Equipped with a 1.7 MHz ultrasonic atomizer that can atomize liquids into fine particles and deliver them into the tube furnace.
  • Heating System (Customizable Tube Furnace): Maximum temperature up to 1200°C.
Technical data

Specifications

Figures below are the manufacturer data for this model. Anything not listed is confirmed in writing with the quotation rather than estimated here.

Power supplyAC220V 1.2KW
T-max1200℃
Long-term Operating Temperature Range300~1150℃
Heating Rate1℃/H-20℃/Min
Heating Zone Length200mm
High-Precision Peristaltic Pump1.Speed range: 0.1 to 100 rpm, reversible; 2.Speed resolution: 0.1 rpm; 3.Speed adjustment: Membrane button; 4.Display mode: 4-digit LED shows current speed or flow rate; 5.Made of reinforced PP material, corrosion-resistant; 6.Flow rate: 0.04-13 ml/min; 7.Equipped with a full-speed button for fast emptying and filling; 8.Features power-off memory to save operating parameters promptly.
Atomizer1.AC220V, 1.7 MHz ultrasonic atomizer;2.Liquid tank made of PTFE, corrosion-resistant, sealed with a silicone O-ring; 3.Atomization flow rate controlled by a gas flow meter; 4.Continuous atomization operation; 5.Flow rate: 0.04-13 ml/min.
Control System1.Can store up to 15 temperature curves to avoid the hassle of repeated settings for different experiments; 2.More intuitive experimental process, easier operation; 3.Optional wireless control module for remote operation; 4.Features over-temperature alarm, thermocouple break warning, and leakage protection.
Heating ElementMo-doped Fe-Cr-Al alloy.
Flow ControlEquipped with a standard float flowmeter, flow range 60-600 ml/min (other ranges can be customized upon request).
Net Weight30KG
Usage Precautions1.Do not open the furnace chamber when the temperature is ≥300°C to avoid injury. 2.When using the equipment, ensure that the pressure inside the tube does not exceed 0.125 MPa (absolute pressure) to prevent the sealing flange from being blown off due to excessive pressure. 3.When used in high vacuum conditions (10⁻³ Pa), the operating temperature should not exceed 800°C.
Service SupportOne-year limited warranty with lifetime support (consumable parts such as processing tubes and O-rings are not covered under warranty and should be ordered separately under related products).

Processes This Unit Supports

These are the applications ZYLAB lists this model under. Each link opens the full equipment set for that process, which is useful when a project needs more than one machine.

Who Orders It

Fields this model already works in, plus what ZYLAB puts behind it: a 2-year warranty on most products, glass excluded, spare parts in stock and free application support by WhatsApp or email.

Buyer questions

Ordering Ultrasonic Atomization CVD Furnace

What is Ultrasonic Atomization CVD Furnace typically used for?

This Ultrasonic Atomization CVD Furnace is an Aerosol-Assisted Chemical Vapor Deposition (AACVD) system (using liquid/gas aerosol precursors to grow on substrates), designed for applications such as fuel cells and ZnO transparent conductive films. It consists

Can Ultrasonic Atomization CVD Furnace be customised for our process?

Yes. Chamber or tube size, temperature profile, atmosphere, gas path, control system and data recording can all be adapted. Send us your process conditions and sample details and our engineers work out a configuration with you.

How quickly can Ultrasonic Atomization CVD Furnace be shipped?

Most standard ZYLAB models are held in stock. After testing and packing we normally ship Ultrasonic Atomization CVD Furnace within 3 to 7 days. Customised builds are scheduled after the drawing is confirmed, and we give you the date in writing before the order is placed.

How is Ultrasonic Atomization CVD Furnace packed for export?

Packing is chosen for the safety of the machine against freight cost, typically a plywood or wooden crate with internal padding and vacuum-sealed accessories. Export documents such as Form A, Form E and Form F can be issued to help you save duty.

Can you supply items that are not on this page?

Yes. We have access to the complete lines of most of our suppliers and build custom equipment in our own factory, so tell us what the experiment needs and we will source or make it.

Quote For Ultrasonic Atomization CVD Furnace

Tell us the sample, the temperature and the atmosphere. You get the configuration, the price and the despatch date in one reply.