Nepson Industrial Co., Ltd · Shenzhen China · Since 2006
Static Frequency Converters And Transfer Switches Built To Order

Static Frequency Converters And Transfer Switches Built To Order

Nepson Industrial designs and manufactures AC power sources, static transfer switches and shore power conversion systems in Shenzhen since 2006.

Test Power That Simulates Any Grid In The World

Test Power That Simulates Any Grid In The World

HPA programmable AC power sources deliver 0-300 VAC at any frequency from 40 Hz to 499.9 Hz for R&D, production test and QA verification.

Seamless Dual Source Switching For Critical Loads

Seamless Dual Source Switching For Critical Loads

Three phase static transfer switches from 63 A to 400 A transfer between two independent feeds in 6 ms or less at 98 percent efficiency.

What We Make

Power Conversion And Transfer Equipment Built In Our Own Plant

Static frequency converters, programmable AC power sources, three phase static transfer switches and shore power conversion systems, built in our own Shenzhen plant.

Static Transfer Switch

Static Transfer Switch

Solid state switches that move a critical load between two independent power feeds without an interruption the load can detect.

Explore Category
AC Power Sources And Inverters

AC Power Sources And Inverters

Programmable AC power sources that reproduce the voltage and frequency of any national grid on your test bench.

Explore Category
Shore Power Supply

Shore Power Supply

Static frequency converters that let a berthed vessel shut down its diesel generators and run on shore supply.

Explore Category
Products

Every Product We Build

Full specifications, protection behaviour and dimensions for each model are published on the product pages.

HPA Programmable AC Power Source

HPA Programmable AC Power Source

The HPA series is a variable frequency AC power source that reproduces the voltage and frequency used in any country on a single bench. It delivers...

View Specifications
3 Phase Static Transfer Switch

3 Phase Static Transfer Switch

The STS is built with two independent power inlets. The load normally runs from the primary source. If the primary source fails, the secondary source...

View Specifications
Shore Power Static Frequency Converter

Shore Power Static Frequency Converter

A static frequency converter sized for quayside shore connection, from 1000 kVA to 4000 kVA. It takes the local port supply and delivers a clean IT...

View Specifications
Who We Serve

Industries We Supply

Ports and container terminals, shipyards and vessel owners, data centre and telecom operators, and export manufacturers who must test products on foreign grid voltages and frequencies.

Ports And Container Terminals

Berthed vessels burn fuel in auxiliary engines unless the quay can hand them power at the frequency and voltage their switchboard expects. That is a conversion problem, not a cable problem.

Marine And Shipyards

A yard supplies dozens of vessels that were built for different grids. Conversion equipment on the dock removes the argument about whose frequency is correct.

Data Centres And Telecom Sites

Redundancy only pays off if the changeover is faster than the load notices. A static transfer switch makes the second feed useful instead of decorative.

Industrial Plants

Control cabinets and process instruments are cheap compared with the batch they supervise. Keeping them energised through a feed fault is the whole job.

What Problem We Solve

The Supply Adapts To The Load Not The Other Way Round

Equipment fails, trips or has to be certified twice when the supply frequency, voltage or source reliability does not match what the load was designed for. We convert and stabilise the supply instead of forcing the load to compromise.

Wrong Frequency

A 60 Hz machine on a 50 Hz grid runs slow and draws higher magnetising current. Static conversion gives it the supply it was designed for.

Single Point Of Failure

A second feed only counts as redundancy when the transfer is inside the ride through window of the load. Ours is 6 ms or less.

Unrepeatable Test Results

Grid distortion moves production measurements between shifts. An isolated pure sine wave source removes it from the test.

Why Choose Us

Numbers That Decide A Specification

One factory covers R&D, assembly and test. Input and output voltage levels are customised per project, cabinets go out air cooled or in IP65 containers, and every unit is tested before it ships.

2006Founded
6 ms or lessSTS Transfer Time
1000 to 4000 kVAConverter Capacity
40 to 499.9 HzOutput Frequency
Solutions

How A Project Runs From Survey To Commissioning

Shore Power Conversion Projects

From the first berth load survey to a commissioned converter on the quay, every stage has a decision that is expensive to revisit later.

See The Process

Dual Source Power Redundancy

A second feed is only redundancy if the load transfers onto it faster than it can notice. This is what that design looks like end to end.

See The Process

Export Product Power Testing

Testing a product on the grid you happen to have is how field failures get discovered by the customer. Here is the alternative.

See The Process
Inside The Plant

Assembly Test And Despatch In Shenzhen

Cabinets are fabricated, wired, burned in and tested in house before they are packed.

Completed AC power source cabinets staged in the Shenzhen assembly area before final test
Completed AC power source cabinets staged in the Shenzhen assembly area before final test
Cabinet row with doors open during wiring and pre delivery inspection
Cabinet row with doors open during wiring and pre delivery inspection
Packed AC power source units at the Nepson Industrial office ready for collection
Packed AC power source units at the Nepson Industrial office ready for collection
Multi section static frequency converter cabinet with touch screen control panel
Multi section static frequency converter cabinet with touch screen control panel

Quality Checks Before Despatch

  • Insulation resistance measured with a 1000 V megohm meter
  • Withstand voltage test, 2500 VAC low voltage and 42 kVAC high voltage for one minute
  • Protection trip values set and exercised
  • Full load run and output waveform verification before dispatch
Knowledge Centre

Guides For Engineers Specifying Power Equipment

FAQ

Questions Buyers Ask

What does Nepson Industrial actually manufacture?

AC power sources and inverters, three phase static transfer switches, and shore power static frequency converters from 1000 kVA to 4000 kVA.

Can the output voltage and frequency be customised?

Yes. Input and output voltage levels are set per project, and converter output can be 50 Hz, 60 Hz or 400 Hz.

Where is the factory?

Longhua District, Shenzhen, China. The company was established in 2006.

How do I get a quotation?

Send the load, voltage, frequency and site conditions by WhatsApp or email and an engineer will size the equipment against them.

Send Us The Load And We Will Size The Equipment

Give us the voltage, frequency, current and site conditions. An engineer will come back with a model number and a drawing, not a brochure.