3 Phase Static Transfer Switch
The STS is built with two independent power inlets. The load normally runs from the primary source. If the primary source fails, the secondary source...
View Specifications
A static frequency converter sized for quayside shore connection, from 1000 kVA to 4000 kVA. It takes the local port supply and delivers a clean IT system output at 50 Hz, 60 Hz or 400 Hz so a berthed vessel...
A static frequency converter sized for quayside shore connection, from 1000 kVA to 4000 kVA. It takes the local port supply and delivers a clean IT system output at 50 Hz, 60 Hz or 400 Hz so a berthed vessel can shut its auxiliary engines down. Container type units are rated IP65 for the quay, indoor type units are rated IP32 for a substation room.

Every figure below comes from the manufacturer data for this model family.
| Capacity | 1000, 1250, 1600, 2000, 3000 and 4000 kVA |
|---|---|
| Ambient Temperature | -10 to 45 degrees C |
| Relative Humidity | 0 to 95 percent |
| Protection Class | Container type IP65, indoor type IP32 |
| Cooling | Container type air conditioned, indoor type forced air |
| Altitude | Rated output continuous below 1000 m, derate above |
| Input Frequency | 50 Hz or 60 Hz, plus or minus 10 percent |
| Input System | IT system or TN-C-S system |
| Rectifier | 6 pulse, 12 pulse or PWM |
| Input Power Factor | 6 pulse 0.90 or better, 12 pulse 0.96 or better, PWM 0.99 or better |
| Input Current THD | 6 pulse 35 percent or less, 12 pulse 6 percent or less, PWM 5 percent or less at full load |
| Output System | IT system with neutral insulation |
| Rated Output Line Current | 1312 A at 440 V for 1000 kVA, up to 5249 A at 440 V or 350 A at 6.6 kV for 4000 kVA |
| Output Frequency | 50 Hz, 60 Hz or 400 Hz, accuracy 0.01 |
| Frequency Stability | 0.01 percent or better from no load to full load |
| Static Voltage Regulation | 0.5 V or less |
| Dynamic Voltage Regulation | Within 1 percent on stepped load, within 3 percent on 100 percent load step |
| Output Voltage THD | 1 percent or less on no load or linear load |
| Output Voltage Imbalance | Less than 1 percent |
| Phase Angle | 120 degrees plus or minus 0.1 degree |
| Overload | 125 percent for 1 minute, alarm and cut off at 150 percent |
| Overall Efficiency | 95 percent or better at full rated load |
| Noise | 55 dB(A) or less |
| Container Dimensions | 6058, 9000 or 12192 mm long x 2438 x 2896 mm |
| Indoor Dimensions | 4300, 9400 or 12000 mm long x 1500 x 2300 mm |
| Weight | 4 to 25 t depending on rating and housing |
| Withstand Voltage | Low voltage 2500 VAC for 1 minute, high voltage 42 kVAC for 1 minute |
| Cold Insulation Resistance | 100 megohm or more measured at 1000 V |
| Running ship auxiliary engines at berth | Shore conversion removes fuel burn, exhaust and vibration at the quay for the whole stay. |
|---|---|
| Rotary frequency converter set | A rotary set carries rotating mass and maintenance. The static converter holds frequency to 0.01 accuracy with no wearing parts. |
4000 kVA, with a rated output line current of 5249 A at 440 V or 350 A at 6.6 kV.
Output frequency accuracy is 0.01 and stability is within 0.01 percent from no load to full load.
Yes. The container type is rated IP65 and is fully air conditioned. The indoor type is IP32 with forced air cooling.
Noise is 55 dB(A) or less.
From 4 t for the smallest indoor unit up to 25 t for the largest container unit.
The STS is built with two independent power inlets. The load normally runs from the primary source. If the primary source fails, the secondary source...
View Specifications
The HPA series is a variable frequency AC power source that reproduces the voltage and frequency used in any country on a single bench. It delivers...
View SpecificationsSend the rating, voltage, frequency and site conditions. We will confirm the model number and the cabinet dimensions.