Autosampler Vial

13-425 Sample Vial and Cap and Septa

The 13-425 autosampler vial is a standard ND13mm open-top screw-top vial made from borosilicate glass, designed for reliable sample storage and injection in HPLC and GC analysis. It is compatible with Agilent, Shimadzu, and Waters autosamplers. The vial features a flat bottom for stable placement in inserts and is available in clear or amber glass with or without a writing area. Pre-assembled caps and pre-slit PTFE/silicone septa reduce handling and contamination risk during sample preparation.

  • Standard ND13mm screw-top design ensures compatibility with Agilent, Shimadzu, and Waters autosamplers
  • Borosilicate glass construction resists chemical attack and thermal shock during routine lab use
  • Flat bottom design provides stable positioning in autosampler inserts and reduces vial tipping
  • Pre-slit PTFE/silicone septa allow easy needle penetration without additional tooling
Key Benefits

What This Product Gives You

  • Standard ND13mm screw-top design ensures compatibility with Agilent, Shimadzu, and Waters autosamplers
  • Borosilicate glass construction resists chemical attack and thermal shock during routine lab use
  • Flat bottom design provides stable positioning in autosampler inserts and reduces vial tipping
  • Pre-slit PTFE/silicone septa allow easy needle penetration without additional tooling
  • Pre-assembled caps and septa minimize handling and reduce the risk of contamination
  • Available in clear and amber glass to protect light-sensitive samples
  • Writing area option supports sample identification directly on the vial
  • Regular stocking enables delivery within 3 to 5 days for urgent orders
  • Volume: 4 ml
  • Neck type: 13-425 screw top
  • Size: 15 mm diameter × 45 mm height
  • Borosilicate glass construction
  • Flat bottom for stable insert placement
  • Pre-slit PTFE/silicone septa for easy needle penetration
  • Available in clear and amber glass
  • Writing area option on select vial types
  • Pre-assembled cap and septa configuration
Where It Is Used

Applications And Buyers

Application Scenarios

  • Storing and injecting HPLC and GC samples in pharmaceutical QC laboratories
  • Preparing environmental and food matrix samples for residue analysis with light-sensitive compounds
  • Handling high-throughput sample batches in contract research organisations
  • Using in routine analysis where consistent vial geometry and sealing performance are required
  • Supporting method transfer between different autosampler platforms due to standard ND13mm fit

Who It Is For

  • Pharmaceutical and biotech labs requiring consistent vial performance across multiple HPLC and GC methods
  • Environmental and food testing labs handling light-sensitive or volatile analytes
  • Contract laboratories managing high sample volumes with tight turnaround times
  • Lab distributors sourcing a standard vial format with multiple configuration options
  • OEM partners needing a reliable, pre-assembled vial system for private-label packaging

Problems It Solves

  • Vials tipping in autosampler inserts due to uneven or domed bottoms
  • Needle damage or poor seal integrity from non-pre-slit or poorly designed septa
  • Contamination from repeated handling during cap and septa assembly
  • Inconsistent fit with autosamplers due to non-standard vial neck dimensions
  • Loss of sample integrity due to light exposure in clear vials containing photosensitive compounds
  • Delays in sample preparation caused by manual septa cutting or cap assembly
  • Inability to identify samples quickly when labels are lost or not applied
Data

Specifications

Volume4 ml
Neck Type13-425 screw top
Size15 mm × 45 mm
Vial MaterialBorosilicate glass
Vial ColorClear, Amber
Writing AreaAvailable on select models
Cap MaterialPP
Septa MaterialPTFE/Silicone
Septa TypePre-slit
Packing100 pcs per pack

Materials

  • Borosilicate glass vial
  • PTFE/silicone septa

Customization Options

  • Choice of clear or amber vial
  • Option with or without writing area
  • OEM private-label printing on vials and packaging
  • Custom cap and septa configurations available through OEM service
  • Flexible packaging options for bulk orders
How It Is Made

Manufacturing And Quality Control

Manufacturing Process

  • Borosilicate glass vial forming and annealing
  • Neck threading and dimensional inspection
  • Septa die-cutting and pre-slit formation
  • Pre-assembly of cap and septa
  • Final inspection and packing in PP boxes

Quality Control

  • Vial dimensions verified against 13-425 standard
  • Cap and septa assembly checked for correct alignment and sealing
  • Septa pre-slit integrity tested for consistent needle penetration
  • Visual inspection for glass defects and surface contamination
  • Packing verified to contain 100 units per box
Comparison

Compared With The Alternatives

Versus Vials with domed bottoms

The flat bottom ensures stable placement in autosampler inserts, reducing the risk of tipping during injection

Versus Non-pre-slit septa

Pre-slit septa allow consistent needle penetration without additional tooling or risk of septa damage

Versus Separate cap and septa assembly

Pre-assembled components reduce handling and contamination risk during sample preparation

Versus Standard glass vials without writing area

The writing area option enables direct sample identification, reducing label loss and mislabelling

Use Guide

How To Use It

  • Select clear vials for general use or amber vials for light-sensitive samples
  • Use vials with a writing area when direct sample identification is required
  • Ensure the septa is pre-slit and properly seated before placing the cap
  • Insert the vial into the autosampler insert with the flat bottom down
  • Use a needle with a sharp tip to pierce the pre-slit septa cleanly
  • Avoid over-tightening the cap to prevent damage to the septa or thread
  • Discard the first few microlitres of sample if the method is sensitive to septa leachables
Photos

Product Gallery

Also In This Category

Related Products

Read Next

Related Industries And Guides

FAQ

Questions Buyers Ask

Are these vials compatible with Agilent, Shimadzu, and Waters autosamplers?

Yes. The 13-425 neck type is a standard ND13mm open-top screw-top design, compatible with Agilent, Shimadzu, and Waters autosamplers

What is the difference between the clear and amber vials?

Clear vials are suitable for general use. Amber vials protect light-sensitive samples from degradation

Can I use these vials for volatile or aggressive solvents?

Yes. Borosilicate glass is resistant to most solvents and temperature changes encountered in HPLC and GC analysis

Do you offer OEM services for private-label packaging?

Yes. The Microlab OEM division supports custom printing, private-label packing, and custom cap/septa configurations

What is the packing quantity?

All vials are packed in PP boxes of 100 units per pack

How long does delivery take?

Due to regular stocking, delivery is available within 3 to 5 days

Are the septa pre-slit?

Yes. The septa are pre-slit for easy needle penetration without additional tooling

Get A Quote For 13-425 Sample Vial and Cap and Septa

Tell us the membrane, pore size, diameter and quantity you need, or describe the sample and we will specify it.