Coating and ink raw materials from Tianjin, China Monday to Friday, 09:00-18:00 China Standard Time (GMT+8) [email protected] +86-1502260163
  1. Home
  2. Solutions
  3. Equivalent Grade Sourcing
Textured brand panel behind the page title
Solution

Equivalent Grade Sourcing

You already know which commercial grade your formulation is built around. This is how a QK alternative gets qualified without guesswork.

Nothing here promises a drop-in replacement. What the published cross-reference does is tell you which QK grade was designed against which commercial grade, so a trial starts from the right chemistry and the right dosage band instead of a blank sheet. The rest is your own testing, and these are the stages it usually takes.

Stage By Stage

Equivalent Grade Sourcing In 6 Steps

Identify the incumbent

The formulation names a commercial grade but nobody has the chemistry written down.

Look the grade up in the sixty-nine row cross-reference list. It returns the QK number and the additive function, which is enough to pull the right technical page.

Compare the published data

Two additives with the same function can differ in active content, carrier and pH, which changes the dosage arithmetic.

Every QK page publishes active content, density, solvent or carrier, pH where relevant, storage window and shelf life. Compare those against the incumbent data sheet before any sample moves.

Set the dosage band

A single recommended percentage hides the fact that dosage depends on pigment class.

Dosage is published as a ladder: inorganic, organic, titanium dioxide and carbon black are quoted separately, and all of them are on pigment weight, not on the batch.

Run the trial

A trial that changes two variables at once tells you nothing.

Hold the grind and let-down constant, run three dosage points across the published band, and measure the property that failed originally: grind fineness, mill base viscosity, jetness, sag resistance or orientation.

Check the handling constraints

Most additive trials fail on handling, not on chemistry.

Addition point, shear level and pH adjustment are published for every grade. QK8521 needs system pH at 9-9.5 first. QK3770 and QK3755 need a resin-free grind. QK3320 needs resin and solvent premixed before the additive goes in.

Confirm stability before scale-up

A mill base that looks right on day one can flocculate in the warehouse.

Store samples at both ends of the published storage window, re-measure viscosity and run a rub-out on mixed shades before committing a production batch.

Questions

Equivalent Grade Sourcing Questions

Is a QK grade a drop-in replacement?
No, and nothing on this site claims it is. The cross-reference tells you which commercial grade a QK product was positioned against so a trial starts in the right place. Qualification is your own testing.
What information helps you recommend a grade?
The binder system, whether it is waterborne, solventborne, UV or plastisol, the pigment classes in use, and the defect or property you are trying to fix.
How long does a sample take?
Sample lead time is confirmed per request by email, since it depends on the grade and the quantity.

Start On Equivalent Grade Sourcing

Send the formulation details and the constraint you are working against. A recommended starting point with the matching data sheets comes back by email.