We reply to enquiries within 12 hours · Mon-Sat 08:30-18:00 GMT+8[email protected]+86 18155106856
BESS Power Storage Containers

Outdoor Liquid Cooling ESS Cabinet 261kWh 125kw

125 kW / 261 kWh

Outdoor Liquid Cooling ESS Cabinet 261kWh 125kw is an outdoor all-in-one energy storage cabinet rated at 125 kW / 261 kWh. It arrives wired and tested, which removes the rack-by-rack integration work that normally sits on the EPC's critical path.

Standards Referenced On The Original Datasheet

  • IEC62619
  • UN38.3
Key Benefits

What This Product Changes On Your Project

  • Pre-integrated and factory-tested, so site work is foundation, cabling and commissioning rather than assembly
  • Battery, thermal management, BMS and fire suppression are specified against each other by one supplier
  • Modular capacity - additional units run in parallel as the site load or tariff exposure grows
  • Sized for peak shaving and demand-charge reduction, where the payback is a billing line item rather than a generation estimate
  • Remote monitoring over standard industrial protocols, so the system reports into an existing SCADA or EMS

Application Scenarios

  • Industrial sites bridging short utility interruptions without starting a generator
  • Grid-side projects providing frequency and capacity support
  • Sites whose grid connection cannot be upgraded, using storage instead of more feeder capacity
  • Mining, quarry and remote industrial sites running a diesel-PV-storage hybrid
  • EV charging hubs buffering the grid draw of simultaneous fast-charge sessions

Who It Is For

  • EPC contractors delivering commercial and industrial storage projects
  • Industrial plant engineers managing demand charges and process continuity
  • Independent power producers and grid-side project developers
  • Energy service companies building performance-based storage offers

Problems It Solves

  • Battery-room construction, ventilation and fire compliance that can cost more than the batteries
  • Multi-vendor integration risk when cells, PCS and controls come from three suppliers with three warranties
  • Demand charges set by a handful of peak intervals each month rather than by total consumption
  • Grid connection capacity that will not be upgraded in time for the site's growth plan

Technical Features

  • Industrial communication interfaces for SCADA, EMS and remote diagnostics
  • Cells, racks, BMS, thermal management and fire suppression integrated and tested before shipment
  • Multi-level BMS monitoring cell voltage, current and temperature and reporting to the site controller
  • Thermal management sized to hold cell temperature spread across the pack, which is what drives uneven ageing
  • Fire detection and suppression designed into the enclosure rather than added by the installer
Specifications

Published Specification Data

These figures come from the manufacturer datasheet for this model. Where a value you need is not listed, ask for the full datasheet rather than assuming a typical figure.

Rated power125 kW
Energy capacity261 kWh
CoolingLiquid cooling

Quality Control

  • Incoming inspection of cells, power electronics and structural parts before assembly
  • Capacity and internal-resistance grading so cells within a pack are matched
  • Full-function test on every finished unit, not a sample from the batch
  • Insulation and dielectric withstand testing on completed assemblies
  • Aged and burn-in run before packing, so early-life failures happen in the factory

Customization Options

  • Communication protocol mapped to the site's existing EMS or SCADA
  • Cooling and ingress rating selected for the site climate
  • Capacity and power rating configured to the site's measured load profile
  • Grid code and AC voltage set for the destination market
Comparison

How It Compares With The Alternatives

A site-built battery roomThe enclosure, thermal system and fire protection ship as one tested assembly, so the site does not have to build, ventilate and certify a room for them.
A diesel generatorStorage responds in milliseconds and has no fuel logistics, but it holds a finite energy budget - most industrial sites end up running both, with storage taking the peaks.
Grid connection upgradeA capacity upgrade is a utility timeline the site does not control. Storage is a capital item the site can schedule itself.
Use Guide

Getting This Product Right On Site

  1. 1

    Commission with the supplier's sequence and record the baseline before the first billing cycle

  2. 2

    Review the demand-charge line on the first two bills against the model and retune the dispatch schedule

  3. 3

    Send twelve months of interval meter data so the system is sized against the real demand curve, not the connected load

  4. 4

    Confirm grid code, AC voltage and any export limitation required by the utility before production

  5. 5

    Prepare a level foundation, cable routes and a clear service envelope around the enclosure

Outdoor Liquid Cooling ESS Cabinet 261kWh 125kw - Buyer Questions

What is the lead time on this system
Lead time depends on configuration and the destination grid code. Send the site load profile and required grid standard and we will confirm a production and shipping schedule with the quotation.
Can the system be sized for our specific load profile
Yes. Capacity and power rating are configured per project. Twelve months of interval meter data gives the most accurate sizing; a monthly bill history is workable if interval data is not available.
What certification does the system carry
Certification depends on configuration and destination market. We confirm the applicable approvals in writing for each project before production - ask for the certificate pack with your quotation.
How is the system shipped and what does the site need to prepare
The unit ships as a pre-integrated enclosure. The site needs a level foundation, cable routes, a clear service envelope and grid connection approval before commissioning.
Can several units run in parallel
Yes. Multiple units operate in parallel under one energy management layer, which is the normal route to expand capacity after the first installation.
Do you support commissioning and after-sales on site
We supply the commissioning sequence and remote support as standard. On-site commissioning is arranged per project - confirm the scope you need when you enquire.

Request A Quote For Outdoor Liquid Cooling ESS Cabinet 261kWh 125kw

Tell us the quantity, the destination market and the application. We reply within 12 hours with lead time, certification and pricing.