HTB2LE-40 residual current circuit breaker

It is intended for use in distribution boards where a standard MCB is replaced with a combined protection device.

Product Overview

What This Model Does

It is intended for use in distribution boards where a standard MCB is replaced with a combined protection device.

Key Benefits

  • Provides combined overload, short-circuit, and residual current protection in a single device
  • Mechanical trip mechanism ensures protection remains active during power or network failure
HTB2LE-40 residual current circuit breaker on DIN rail front view
HTB2LE-40 residual current circuit breaker on DIN rail front view

Who It Is For

  • Electrical wholesalers stocking residual current protection devices
  • Panel builders integrating combined protection into distribution boards
  • Switchgear assemblers specifying RCCB in custom control cabinets
  • Solar EPC contractors installing protection in PV system distribution boards
  • OEM/ODM buyers integrating a compliant residual current device into their own systems

Problems It Solves

  • An existing MCB provides no protection against earth leakage, increasing shock and fire risk
  • Installing separate MCB and RCD increases panel space and wiring complexity
  • Lack of residual current protection in older installations fails to meet modern safety standards
  • Site visits are required to manually reset a tripped RCD when no remote control is available
  • Multiple devices increase the chance of mismatched trip characteristics and coordination issues

Application Scenarios

  • Residential distribution boards where a single device replaces both MCB and RCD
  • Commercial buildings with multiple circuits requiring earth leakage protection
  • Light industrial control panels where space is limited and combined protection is needed
  • Renovations where existing DIN rail panels are upgraded to include residual current protection
  • Installations in areas with higher risk of ground faults such as kitchens, bathrooms, or outdoor circuits
Technical Features

How It Is Built

  • Thermal-magnetic trip mechanism for overload and short-circuit protection

Materials and Construction

  • Silver-alloy contacts with a thermal-magnetic trip mechanism
  • Integrated residual current sensing coil and trip unit

Quality Control

  • Insulation and dielectric withstand test performed before packing
Specifications

Stated Ratings for This Model

Specifications for HTB2LE-40 residual current circuit breaker
Number of Poles2P
Rated Current40A
Pollution Level2

Ratings are as published for this model. Where a value is not published we mark it TBC rather than estimating it.

Values that could not be confirmed against the published catalogue text for this model are marked TBC and confirmed by email before order: Standards Compliant, Rated Voltage, Frequency, Rated Short-circuit Breaking Capacity, Residual Current Trip Threshold, Rated Impulse Withstand Voltage, Protection Level, Specified Use Temperature, Mechanical Life, Electrical Life, Installation Type.

Manufacturing Process

  • Moulding and machining of the breaker housing and internal carriers
  • Assembly of the thermal-magnetic trip unit and contact system
  • Installation of the residual current sensing coil and trip mechanism
  • Routine dielectric and operation testing before packing

Customization Options

  • Rated current selected from the available 40A model per order
  • Pole count supplied as 2P from the same series
  • ODM branding on housing print and packaging
  • Packaging and carton marking to the buyer's own specification
Comparison

How It Compares

Conventional MCBAdds residual current protection but requires a separate RCD for full safety
MCB plus separate RCDOne device instead of two, reducing panel space and wiring complexity

Use Guide

  1. Switch on manually and confirm the breaker holds under normal load before use
  2. Test the residual current trip function using the test button on the device
  3. Ensure the device is not overloaded and the connected load stays within 40A
  4. Keep the manual handle accessible for on-site isolation when needed
  5. Do not operate in environments exceeding the specified use temperature range
FAQ

Questions About the HTB2LE-40 residual current circuit breaker

What is the rated current and pole count

The device is a 2-pole breaker with a rated current of 40A.

Does it still work if the power is off

Yes. The mechanical trip mechanism ensures protection remains active during power loss.

Can we have it branded under our own label

Yes. We support ODM projects and can print your branding on the housing and packaging.

What is the minimum order quantity and lead time

Both depend on the current ratings and branding you need. Email [email protected] with your model list and quantities for a current answer.

How do we get a price for this model

Email [email protected] with the rated current, pole count and quantity you need and we will quote this model directly.

Can this be supplied under our own brand

Yes. We run ODM projects and can print your branding on the housing and packaging.

Get a Quotation for the HTB2LE-40 residual current circuit breaker

Tell us the ratings, pole counts and quantities you need and we will price this model directly.