Since 2007, We Focus on Production [email protected]+86-150-6773-7389
Tuya WIFI Smart Circuit Breakers

Thermal Actuated Condensed Aerosol Fire Suppression Device

The Thermal Actuated Condensed Aerosol Fire Suppression Device is a compact, self-activated fire protection unit...

Product Overview

What This Model Does

The Thermal Actuated Condensed Aerosol Fire Suppression Device is a compact, self-activated fire protection unit designed for enclosed electrical cabinets, distribution boxes, PV inverters, battery compartments and control panels. It requires no external power and activates automatically when internal temperature reaches 120℃. The device releases fine aerosol particles within 15 seconds of activation, suppressing Class B and E fires in ≤6 seconds. It is available in 10g, 20g and 30g agent dosages to match cabinet volume. Installation is simple with DIN rail or 3M adhesive mounting. It operates maintenance-free with a service life up to 10 years and no pressure vessel means no gas leakage or refilling required. It is ideal for integration into electrical equipment where space and reliability are critical.

Key Benefits

  • Self-activates at 120℃ with no external power or wiring to fire alarm panels
  • Extinguishes Class B and E fires in ≤6 seconds after activation
  • No pressure vessel means no gas leakage, no refilling, no pressure testing
  • Compact design fits inside cabinets without requiring pipelines or cylinders
  • DIN rail or 3M adhesive mounting allows quick installation in tight spaces
  • Service life up to 10 years with no maintenance required
  • Minimal corrosion to circuit boards and low-voltage components after discharge
  • Dual temperature probes (top and bottom) allow placement at high-risk hot spots
Thermal actuated condensed aerosol fire suppression device mounted on DIN rail inside an electrical cabinet
Thermal actuated condensed aerosol fire suppression device mounted on DIN rail inside an electrical cabinet

Who It Is For

  • Electrical equipment manufacturers building cabinets and panels with built-in fire protection
  • System integrators specifying fire safety for control systems and inverters
  • Fire protection distributors offering compact, self-contained solutions for electrical enclosures
  • Solar EPC contractors installing fire-safe inverters and battery systems
  • Panel builders adding automatic fire suppression to distribution boards without complex wiring

Problems It Solves

  • A fire starts in a sealed electrical cabinet and spreads before anyone detects it
  • No fire suppression system is installed because wiring to a central alarm is too complex
  • Existing fire systems require regular maintenance, pressure checks or agent refills
  • Space inside a cabinet is too tight for traditional fire suppression with cylinders and pipes
  • Secondary damage from water or chemical agents ruins sensitive electronics after a fire

Application Scenarios

  • Protecting PV inverters in outdoor solar installations where electrical fires can start from overheated components
  • Securing battery compartments in UPS systems or EV charging stations prone to thermal runaway
  • Preventing fire spread in control panels with high-density electronics and limited access
  • Fitting into distribution cabinets in industrial machinery where manual fire suppression is not feasible
  • Integrating into electrical enclosures in remote or unattended sites without a fire alarm system
Technical Features

How It Is Built

  • Self-activation at 120℃ with no external power or signal required
  • Aerosol generation within 15 seconds of temperature threshold reached
  • Fire suppression completed in ≤6 seconds after activation
  • No pressure vessel – zero risk of gas leakage or agent loss
  • DIN rail or 3M adhesive side mounting options for flexible installation
  • Operating temperature range from -50℃ to +90℃
  • Humidity tolerance up to 95% RH (non-condensing)
  • Service life up to 10 years with no maintenance
  • Dual temperature probes (top and bottom) for strategic placement
  • Agent dosage options: 10g, 20g, 30g for different cabinet volumes

Materials and Construction

  • Flame-retardant plastic housing for compact and lightweight construction
  • Thermal heat probe with dual sensor capability (top and bottom)
  • S-type condensed aerosol agent with low corrosivity to electronics
  • Internal ignition system with no external power source required

Quality Control

  • Activation tested at exactly 120℃ to confirm trigger reliability
  • Suppression time verified under lab conditions to ensure ≤6 seconds
  • Thermal probe response checked across the full -50℃ to +90℃ range
  • Humidity exposure test at 95% RH to confirm non-condensing operation
  • Seal integrity tested to ensure no agent leakage over 10-year life
  • Final unit tested for mechanical mounting and probe cable flexibility
Specifications

Stated Ratings for This Model

Specifications for Thermal Actuated Condensed Aerosol Fire Suppression Device
Activation Temperature120℃
Activation TimeWithin 15 seconds of threshold
Suppression Time≤6 seconds
Agent Dosage10g, 20g, 30g
Operating Temperature-50℃ to +90℃
Humidity ToleranceUp to 95% RH (non-condensing)
Service LifeUp to 10 years
Mounting TypeDIN rail or 3M adhesive side mount
Probe Cable LengthStandard 10cm; customizable from 10cm to 50cm per probe
Fire Class SuppressedClass B and E (live electrical fires)
Pressure VesselNone – no gas leakage risk
MaintenanceMaintenance-free

Ratings are as published for this model. Where a value is not published we mark it TBC rather than estimating it.

Manufacturing Process

  • Moulding of the flame-retardant plastic housing and internal components
  • Assembly of the thermal heat probe and dual sensor system
  • Filling of the S-type condensed aerosol agent into the sealed chamber
  • Integration of the ignition system and thermal trigger mechanism
  • Testing of activation at 120℃ and suppression time under controlled conditions
  • Final inspection and packaging with probe cable length as specified

Customization Options

  • Probe cable length customizable from 10cm to 50cm per probe
  • Agent dosage selected from 10g, 20g or 30g based on cabinet volume
  • Mounting type selected as DIN rail or 3M adhesive side mount
  • Packaging and carton marking available to buyer's specification
  • No ODM branding or housing printing currently mentioned in source
Comparison

How It Compares

Conventional fire suppression with pressure vesselNo pressure testing, refilling or leakage risk; lighter and smaller for tight spaces
Wired smoke or heat detector with external fire panelNo wiring or integration needed; self-contained and faster to deploy
Water mist or foam systemNo secondary damage to electronics; works in sealed enclosures without drainage
Manual fire extinguisherAutomatic activation ensures response even when no one is present

Use Guide

  1. Select the correct agent dosage (10g, 20g, or 30g) based on cabinet volume and fire risk
  2. Choose mounting type: DIN rail or 3M adhesive side mount depending on space
  3. Position the heat probe at the highest risk point inside the cabinet (e.g., near transformers or connections)
  4. Fix the device securely using the chosen method without obstructing airflow
  5. Ensure the probe cable is routed safely and not damaged during installation
  6. Do not cover or block the device after installation to allow full activation
  7. Verify that the device is not exposed to temperatures exceeding +90℃ or below -50℃

Related Products

FAQ

Questions About the Thermal Actuated Condensed Aerosol Fire Suppress

What temperature triggers the device

It activates automatically when the internal temperature reaches 120℃.

Does it need external power to work

No. It operates entirely on thermal energy and requires no wiring or power supply.

How long does it take to suppress a fire

It starts aerosol generation within 15 seconds and suppresses the fire in ≤6 seconds.

Can I customize the probe cable length

Yes. Standard is 10cm per probe; custom lengths from 10cm to 50cm are available.

What fire classes does it protect against

It is designed for Class B (flammable liquids) and Class E (live electrical) fires.

How long is the service life

The device has a service life of up to 10 years with no maintenance required.

Is there a risk of gas leakage

No. It has no pressure vessel, so there is zero risk of gas leakage or agent loss over time.

Get a Quotation for the Thermal Actuated Condensed Aerosol Fire Suppress

Tell us the ratings, pole counts and quantities you need and we will price this model directly.