The DZ47LE-63 ELCB is a residual current device for AC 50Hz/60Hz systems with rated voltages of 230V (1P+N, 2P) or 400V...

Product Overview

What This Model Does

The DZ47LE-63 ELCB is a residual current device for AC 50Hz/60Hz systems with rated voltages of 230V (1P+N, 2P) or 400V (3P, 3P+N, 4P), covering rated currents from 6A to 63A. It provides overload and short-circuit protection alongside residual current detection, suitable for infrequent switching of lines and motors. Built to IEC61009, it detects leakage currents down to 0.03A and trips within 0.1 seconds at 5 times the rated residual current. For panel builders and installers, it offers a compact, DIN rail-mounted solution that combines overcurrent and earth leakage protection in one device.

Key Benefits

  • Combines overcurrent and residual current protection in a single DIN rail device
  • Trip time under 0.1 seconds at 5×In for fast fault clearance
  • Available in 1P+N, 2P, 3P, 3P+N, and 4P configurations for flexible circuit design
  • Supports multiple residual current thresholds including 0.03A, 0.05A, 0.1A, and 0.3A
  • Rated short-circuit breaking capacity of 6kA for 6–32A and 4.5kA for 40–63A
  • Suitable for both residential and light industrial applications with stable performance
DZ47LE-63 ELCB on DIN rail front view showing terminals and pole configuration
DZ47LE-63 ELCB on DIN rail front view showing terminals and pole configuration

Who It Is For

  • Electrical wholesalers stocking combined protection devices
  • Panel builders integrating ELCB into distribution boards
  • Switchgear assemblers building custom control cabinets
  • Solar EPC contractors installing protection in PV systems
  • OEM/ODM buyers requiring a compliant residual current device for branded panels

Problems It Solves

  • A separate MCB and RCD must be installed to meet protection requirements, increasing panel space and cost
  • Faults due to earth leakage go undetected without a dedicated residual current device
  • Manual switching of motors or circuits requires additional contactors or switches
  • Lack of fast trip response at high fault currents increases risk of fire or equipment damage
  • Inconsistent protection levels across different circuits due to mismatched device types

Application Scenarios

  • Residential distribution boards where both overload and earth leakage protection are required
  • Light commercial installations with single-phase or three-phase circuits needing combined protection
  • Motor control circuits with infrequent start and stop operations
  • Industrial control panels where space is limited and dual protection is needed
  • Renewable energy systems such as solar inverters with 230V/400V AC outputs
Technical Features

How It Is Built

  • Designed for AC 50Hz/60Hz systems with rated voltage 230V (1P+N, 2P) or 400V (3P, 3P+N, 4P)
  • Rated current from 6A to 63A with 63A rack rating
  • Rated short-circuit breaking capacity of 6kA for 6–32A and 4.5kA for 40–63A
  • Rated residual making/breaking capacity of 2000A
  • Residual action current options: 0.03A, 0.05A, 0.1A, 0.3A
  • Residual non-action current at 0.5×In
  • Trip time under 0.1 seconds at 5×In for all rated currents
  • Compatible with wire cross-sections from 1mm² to 16mm²
  • Operates reliably in ambient temperatures from -5°C to +40°C

Materials and Construction

  • Silver-alloy contacts with a thermal-magnetic trip mechanism for overcurrent protection
  • Integrated residual current sensing coil and electronic trip unit for leakage detection
  • Internal terminals made of high-conductivity copper alloy for reliable connection

Quality Control

  • Trip characteristic verified against IEC61009 for overcurrent and residual current response
  • Short-circuit breaking capacity confirmed at the rated 6kA or 4.5kA
  • Residual current trip time tested at 5×In to ensure ≤0.1s
  • Dielectric withstand test performed at 2kV for 1 minute
Specifications

Stated Ratings for This Model

Specifications for DZ47LE-63 ELCB
Standards CompliantIEC61009
Frequency50/60Hz
Rated Voltage230V for 1P+N and 2P, 400V for 3P, 3P+N, 4P
Number of Poles1P+N, 2P, 3P, 3P+N, 4P
Rated Current6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rack Rated Current63A
Rated Short-circuit Breaking Capacity6kA for 6–32A, 4.5kA for 40–63A
Rated Residual Making/Breaking Capacity2000A
Rated Residual Action Current0.03A, 0.05A, 0.1A, 0.3A
Rated Residual Non-action Current0.5×In
Residual Current Breaking Time≤0.1s at 5×In
Overcurrent Trip CharacteristicType B, C, or D based on application
Ambient Temperature Range-5 to +40 degrees C
Wire Cross-section Compatibility1mm² to 16mm²

Ratings are as published for this model. Where a value is not published we mark it TBC rather than estimating it.

Values that could not be confirmed against the published catalogue text for this model are marked TBC and confirmed by email before order: Mechanical Life, Electrical Life.

Manufacturing Process

  • Moulding and machining of the breaker housing and internal components
  • Assembly of the thermal-magnetic trip unit and contact system
  • Installation of the residual current sensing coil and electronic trip circuit
  • Calibration of the trip characteristic against IEC61009 requirements
  • Routine dielectric and operation testing before packing

Customization Options

  • Rated current selected from 6A to 63A per order
  • Pole count supplied as 1P+N, 2P, 3P, 3P+N, or 4P from the same series
  • ODM branding on housing print and packaging
  • Packaging and carton marking to the buyer's own specification
Comparison

How It Compares

Separate MCB and RCDReduces panel space and wiring complexity, though with higher unit cost
RCBOSame protection function but with fixed trip current, while RCBO allows more configuration options
Conventional ELCB with separate overcurrent protectionCombines both functions in one device, reducing installation time and part count
4P RCBODZ47LE-63 offers lower cost and simpler design for applications not requiring full RCBO functionality

Use Guide

  1. Connect the line and neutral conductors to the appropriate terminals based on pole count
  2. Ensure the rated current matches the circuit load and wire size
  3. Test the device after installation by pressing the test button to verify trip function
  4. Do not operate if the device shows signs of damage or overheating
  5. Keep the manual test button accessible for periodic functional checks
FAQ

Questions About the DZ47LE-63 ELCB

What rated currents are available for the DZ47LE-63

The series covers 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, and 63A.

Which pole configurations are supported

1P+N, 2P, 3P, 3P+N, and 4P are available for single-phase and three-phase systems.

What standards does it comply with

It conforms to IEC61009 for residual current devices.

What is the short-circuit breaking capacity

6kA for 6–32A and 4.5kA for 40–63A.

Can it be used for motor start and stop

Yes, it is suitable for infrequent motor start and line conversion operations.

What residual current settings are available

0.03A, 0.05A, 0.1A, and 0.3A are supported.

What are the minimum order quantity and lead time

Both depend on the current rating and branding required. Email [email protected] with your model list and quantities for a current answer.

Get a Quotation for the DZ47LE-63 ELCB

Tell us the ratings, pole counts and quantities you need and we will price this model directly.