Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature
The ZYLAB Split-Type Tube Furnace with Stand for Horizontal or Vertical Placement is a compact, high-temperature lab furnace designed for flexible thermal processing. The split design allows for easy access to the tube and sample, while the ability to operate horizontally, vertically, or at an inclined angle supports...

Introduction
The ZYLAB Split-Type Tube Furnace with Stand for Horizontal or Vertical Placement is a compact, high-temperature lab furnace designed for flexible thermal processing. The split design allows for easy access to the tube and sample, while the ability to operate horizontally, vertically, or at an inclined angle supports a wide range of experimental setups—ideal for CVD, VSL growth, or materials research.
Key Features
360° Rotatable Heating Chamber – Enables flexible positioning in horizontal, vertical, or inclined orientations to meet diverse experimental needs.
High-Purity Quartz Tube – Durable and clean, with a maximum temperature of 1200°C (<1 hour) and working temperature range from room temperature to 1150°C.
30-Segment Programmable Control – Allows precise and automated temperature scheduling for complex thermal processes.
7-Inch Color Touchscreen Interface – User-friendly HMI with real-time temperature curve display for intuitive operation.
15 Preset Sintering Profiles – Easily switch between experimental procedures without repetitive setup.
Energy-Efficient Furnace Chamber – Vacuum-formed with high-purity alumina refractory material for uniform temperature and rapid heating.
Chemical Contamination Protection – Special inner lining and premium heating elements extend service life and maintain sample purity.
Double-Layer Steel Housing with Cooling Fan – Maintains exterior surface temperature below 50°C for operator safety.
Ring-Shaped Heating Structure – Open design for quick sintering and convenient observation of small samples.
Multifunctional Flange with Test Ports – Allows insertion of electrodes or gas/environmental probes for in-situ monitoring.
Optional Remote Control Module – Supports remote operation and data download for enhanced control and record-keeping.
Application Fields of Tube Furnace with Horizontal or Vertical Placement
Vapor–Solid–Liquid (VSL) Growth – Supports angled positioning for precise control of vapor flow and material deposition.
Chemical Vapor Deposition (CVD) – Suitable for thin film synthesis and surface coating under controlled atmosphere.
Quenching and Rapid Thermal Processing – Enables fast heat-up and controlled cooling for phase transformation studies.
Nanomaterial and Crystal Synthesis – Ideal for growing nanowires, nanotubes, or single crystals under customized thermal gradients.
Materials Science Research – Used for sintering, annealing, and oxidation experiments on ceramics, metals, and composites.
Semiconductor and Electronics R&D – Applicable in dopant diffusion, layer formation, and substrate heat treatment.
Catalyst Testing and Gas–Solid Reactions – Can be connected to gas control systems for in-situ reaction studies.
University and Industrial Laboratories – A flexible, lab-scale solution for research institutions and innovation centers.
Precautions for Use
Do not open the furnace chamber when the internal temperature exceeds 300°C, as it may cause personal injury.
The internal pressure of the tube must not exceed 0.125 MPa (absolute pressure) during operation to avoid damage caused by overpressure.
When operating under vacuum, the maximum allowable temperature is 800°C.
Gas cylinders typically contain high internal pressure. A pressure regulator must be installed on the gas cylinder when introducing gas into the furnace tube. It is recommended to use a low-pressure regulator with a range of 0.01 MPa to 0.15 MPa for greater precision and safety.
When the furnace temperature exceeds 1000°C, the furnace tube must not be in a vacuum state. The internal pressure must be maintained at atmospheric pressure to avoid damage.
The long-term operating temperature for high-purity quartz tubes should not exceed 1100°C.
During heating experiments, it is not recommended to close both the exhaust and inlet valves on the tube flange. If you must close them for specific processes, continuously monitor the pressure gauge. If the absolute pressure exceeds 0.15 MPa, immediately open the exhaust valve to prevent accidents such as tube rupture or flange ejection.
Advantages of ZYLAB Furnaces
Flexible Customization – Designed to meet diverse laboratory demands
Widely Used in Research and Industry – Reliable performance in materials labs, universities, and production environments
Professional Support – Dedicated technical service and documentation
Efficient Logistics – Timely delivery and global shipment options
How Does a Tube Furnace Work?
Understanding Tube Furnace Temperatures: Medium vs. High-Temperature Applications
Rotary Tube Furnace vs. Horizontal Tube Furnace vs. Vertical Tube Furnace: Which One Suits Your Needs?
Specifications
Figures below are the manufacturer data for this model. Anything not listed is confirmed in writing with the quotation rather than estimated here.
| Model | O1200-50 | |
|---|---|---|
| Power Supply | AC 220V, 1.0 kW | |
| Maximum Temperature | 1200°C (<1 hour) | |
| Rated Temperature | 1150°C | |
| Continuous Working Range | 300–1150°C | |
| Heating Rate | 1°C/hour to 20°C/min | |
| Heating Zone Length | 200 mm | |
| Constant Temperature Zone | 120 mm | |
| Tube Dimensions | Φ50 × 600 mm (OD × Length) | |
| Furnace Dimensions | 350 × 390 × 350 mm (W × D × H) | |
| Temperature Accuracy | ±1°C | |
| Heating Element | Mo-doped Fe-Cr-Al alloy | |
| Control System | Supports storage of up to 15 temperature programs, reducing the need for repeated setup in different experiments. Real-time temperature curves and graphical display make the operation more intuitive and user-friendly. 7-inch full-color touchscreen provides smart human–machine interaction with non-linear temperature correction. Built-in safety functions include over-temperature alarm, thermocouple disconnection warning, and leakage protection. | |
| Sealing System | Vacuum capability up to 10 Pa (mechanical pump) | |
| Pressure Monitoring | Mechanical pressure gauge with sealed, corrosion-resistant housing | |
| Net Weight | 30 kg | |
| Warranty & Support | 18 months(not including consumable parts, such as heating elements, thermocouple), lifetime support. |
Processes This Unit Supports
These are the applications ZYLAB lists this model under. Each link opens the full equipment set for that process, which is useful when a project needs more than one machine.
- General laboratory sample preparation
Who Orders It
Fields this model already works in, plus what ZYLAB puts behind it: a 2-year warranty on most products, glass excluded, spare parts in stock and free application support by WhatsApp or email.
- University and institute research laboratories
Related Projects
Related Equipment
Models from the same family and the same processes, in case a different chamber size or temperature range fits better.

Small Horizontal Tube Furnace for Hydrogen Loss Testing of Iron Powder

Automatic Glass & Material Melting Furnace up to 1700°C

Lab Debinding Furnace with Exhaust Treatment System (afterburner and exhaust fan)

Box Furnace Pyrolysis Solution for High-Quality Biochar Research

1200°C 27L Vacuum Atmosphere Muffle Furnace for Heat Treatment

1200°C High Uniformity Vacuum Debinding Furnace for 3D Printing

Lab Scale Molten Salt Electrolysis Furnace for Metal Refining and Smelting

Multi-Zone High Temperature Quartz Tube Annealing Furnace for Wafer Processing
Ordering Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature
What is Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature typically used for?
The ZYLAB Split-Type Tube Furnace with Stand for Horizontal or Vertical Placement is a compact, high-temperature lab furnace designed for flexible thermal processing. The split design allows for easy access to the tube and sample, while the ability to operate
How quickly can Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature be shipped?
Most standard ZYLAB models are held in stock. After testing and packing we normally ship Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature within 3 to 7 days. Customised builds are scheduled after the drawing is confirmed, and we give you the date in writing before the order is placed.
Can Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature be customised for our process?
Yes. Chamber or tube size, temperature profile, atmosphere, gas path, control system and data recording can all be adapted. Send us your process conditions and sample details and our engineers work out a configuration with you.
What warranty comes with Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature?
Most ZYLAB products carry a 2-year warranty, glass components excluded; the exact term for this model is the one printed in its specification table and repeated on the quotation. Within the warranty period any part that fails through no misuse of your own is replaced free of charge.
Can we get technical help before ordering Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature?
Yes, and it is free. Our technical staff help with model selection, troubleshooting, manuals and application questions whether or not you have ordered from us before. Write to [email protected] or message us on WhatsApp.
Quote For Split-Type Tube Furnace with Stand for Horizontal or Vertical Operation | 1200°C Max Temperature
Tell us the sample, the temperature and the atmosphere. You get the configuration, the price and the despatch date in one reply.