Liquid filter cartridges and housings made in Jiangyan, Taizhou since 2009[email protected]+8618051183600
Finished high flow filter cartridges on the production floor

Home/Products/Filter Housings/SCC Clamp Cartridge Filter Housings

SCC Clamp Cartridge Filter Housings

SCC series stainless steel cartridge filter housings with V band clamp closure. Accepts 3, 5, or 7 cartridges in 10 to 40 inch lengths. 100 psi standa

Overview

What The SCC Clamp Cartridge Does In Your Line

SCC series stainless steel cartridge filter housings feature a V band clamp closure for quick and easy cartridge change-out in commercial and light industrial water applications. They accept 3, 5, or 7 cartridges in lengths from 10 to 40 inch, and are compatible with both SOE 222 and DOE cartridges. The adjustable top plate accommodates varying cartridge lengths. Standard maximum pressure is 100 psi; 150 psi is available on request.

Category: Filter Housings · Industries: Pharmaceutical And Life Science Chemical And Coatings Plants Food And Beverage Plants

Labelled schematic of the SCC Clamp Cartridge Filter Housings showing construction and connection detail
Key Benefits

Why Buyers Pick This Element

  • V band clamp closure enables fast, tool-free cartridge change-out
  • Adjustable top plate accepts cartridge lengths from 10 to 40 inch
  • Holds 3, 5, or 7 cartridges to scale flow capacity without adding vessels
  • Compatible with SOE 222 and DOE cartridge series for direct replacement
  • Standard max pressure of 100 psi; 150 psi available on request
  • Stainless steel construction resists corrosion in water and light industrial service
Who It Is For

Buyers Who Specify This Cartridge

  • Plant engineers maintaining commercial water systems with frequent filter changes
  • Procurement teams replacing worn SCC housings with a direct dimensional equivalent
  • System integrators specifying a robust, quick-change housing for new installations
  • Facility managers looking to standardise on a V band closure for easier maintenance
Problems It Solves

What It Fixes On The Line

  • Long change-out times due to complex bolted closures on older housings
  • Incompatibility between new cartridges and existing housing flanges or seals
  • Limited cartridge count in a housing that cannot meet rising flow demands
  • Corrosion in non-stainless steel housings in water or light chemical service
  • Lack of flexibility in housing design when cartridge length varies across lines
Technical Features

Construction Detail

  • V band clamp closure for secure sealing and fast access
  • Adjustable top plate to accommodate 10, 20, 30, and 40 inch cartridge lengths
  • Housing body made from stainless steel, available in SS304 or SS316L
  • Inlet and outlet connections in NPT or BSP thread, depending on code
  • Accepts 3, 5, or 7 cartridges per housing for scalable flow
  • Compatible with SOE 222 and DOE cartridge series without adapters
Materials

Materials Of Construction

  • Stainless steel body in SS304 (S4) or SS316L (S6) for corrosion resistance
  • Buna O-rings for general water and mild chemical service
  • EPDM O-rings for hot water and general industrial duty
  • Silicone O-rings where low extractables are required
  • Viton O-rings for aggressive chemicals and higher temperature service
  • Polished or sand blast finish on the housing exterior
Specifications

SCC Clamp Cartridge Filter Housings Specifications

Every figure below comes from the manufacturer data for this series. Anything not listed here is not published and we will confirm it against your duty before you order.

SeriesSCC
Cartridge Capacity3, 5, or 7 cartridges
Cartridge Lengths10, 20, 30, 40 inch
MaterialSS304 (S4), SS316L (S6)
Max Pressure100 psi standard, 150 psi on request
Inlet/Outlet ThreadNPT or BSP
FinishPolished or sand blast
O-ring OptionsBuna (B), EPDM (E), Silicone (S), Viton (V)
Adapter TypeV band clamp
Order Code ExampleSCC-7-40-S4-2-N-B
Application Scenarios

Where It Is Installed

Commercial water filtration where frequent cartridge change-out is needed

Light industrial process water systems requiring quick maintenance access

RO pretreatment skids using SOE 222 or DOE cartridges that need housing replacement

Facilities upgrading from older clamp-style housings to V band closure

Water treatment lines where downtime must be minimised during cartridge replacement

Manufacturing

How This Cartridge Is Built

Media Preparation

Stainless steel body fabrication using precision forming and welding

Pack Forming

Polishing or sand blasting to achieve specified surface finish

Hardware Assembly

V band clamp assembly with adjustable top plate for cartridge length variation

End Cap Bonding

Threaded inlet and outlet port installation in NPT or BSP

Configuration

O-ring groove machining and O-ring installation based on order code

Inspection And Packing

Final inspection and packaging for shipment

Quality Control

Checks Before It Ships

  • Dimensional check of housing bore, clamp ring, and flange alignment
  • Pressure test at 100 psi to verify seal integrity and structural strength
  • O-ring compound and groove fit verification before final assembly
  • Thread inspection for correct size and pitch in NPT or BSP
  • Visual inspection for weld quality, surface defects, and finish consistency
Customization

What We Can Change For You

  • Choose between SS304 (S4) or SS316L (S6) material for corrosion resistance
  • Select inlet/outlet thread type: NPT or BSP
  • Pick O-ring compound: Buna, EPDM, Silicone, or Viton
  • Specify cartridge count: 3, 5, or 7, based on flow and space needs
  • Request 150 psi rating if operating pressure exceeds 100 psi
  • Custom marking or labeling available for bulk orders
Comparison

How It Compares With The Alternatives

Traditional bolted clamp housingsSCC V band closure allows faster change-out and better sealing with less torque required
Swing bolt housingsSCC has a more robust clamp design and better seal integrity under pressure
Plastic housingsSCC offers higher pressure rating and better durability in harsher environments
Other stainless steel housings with different closure typesSCC’s V band design provides quicker access and more consistent sealing across multiple change-outs
Use Guide

Installing And Running This Cartridge

  • Confirm the cartridge length and number of cartridges needed before ordering
  • Ensure the inlet and outlet thread (NPT or BSP) matches your piping system
  • Select the O-ring compound based on fluid type and temperature
  • Request 150 psi rating if your system operates above 100 psi
  • Use the adjustable top plate to align with the cartridge length being installed
  • Inspect the V band clamp and O-ring before each change-out for wear or damage
FAQ

SCC Clamp Cartridge Filter Housings FAQ

Will the SCC housing fit my existing SOE 222 or DOE cartridges?
Yes. SCC housings are designed to accept both SOE 222 and DOE cartridges without adapters. Confirm the cartridge length and number of cartridges in your system.
What is the maximum operating pressure?
Standard max pressure is 100 psi. A 150 psi rating is available on request. Tell us your operating pressure and we will confirm the correct configuration.
What O-ring should I use for my fluid?
Buna for general water, EPDM for hot water, Silicone for low extractables, Viton for aggressive chemicals. Let us know your fluid and temperature for a recommendation.
Can I get a housing with 150 psi rating?
Yes. 150 psi is available on request. Specify this in your order code when placing the order.
How do I write the order code?
SCC-[cartridge count]-[length]-[material]-[thread]-[O-ring]. For example, SCC-7-40-S4-2-N-B is a 7-cartridge housing, 40 inch long, SS304, 2 inch BSP, Buna O-ring.
Can I get a sample before placing a bulk order?
Yes. Message us on WhatsApp with your application, cartridge type, and required pressure rating, and we will send a sample housing for evaluation.

Send Us Your Housing Model And Duty

Send the housing model and the code on the element you use today and we will confirm whether SCC Clamp Cartridge Filter Housings is the right match before you order.