Home/Products/Pleated Filter Cartridges/PFA Fluoropolymer Membrane Filter Cartridges
PFA Fluoropolymer Membrane Filter Cartridges
PFA Fluoropolymer Membrane Filter Cartridges with 500°F max temperature and 60 psi forward pressure. Dimensional equivalent to OEM series.
What The PFA Fluoropolymer Membrane Does In Your Line
PFA Fluoropolymer Membrane Filter Cartridges use expanded PTFE membranes with PFA core, cage, and end caps. All components are fluoropolymer, providing resistance to aggressive chemicals, high temperatures, and strong oxidizing agents. The cartridge operates outside-in and is dimensionally equivalent to common OEM series, allowing direct replacement in existing housings without modification.
Category: Pleated Filter Cartridges · Industries: Pharmaceutical And Life Science Electronics And Semiconductor Food And Beverage Plants

Why Buyers Pick This Element
- All fluoropolymer construction resists strong acids, bases, solvents, and oxidizing gases
- High flow rates with low differential pressure due to hydrophilic PTFE membrane
- PFA encapsulated Viton O-rings maintain seal integrity in aggressive fluids
- No extractables from fluoropolymer materials, suitable for high purity applications
- Dimensional equivalent to installed OEM series, no housing or piping changes needed
Buyers Who Specify This Cartridge
- Chemical plant engineers requiring filtration in highly corrosive environments
- Pharmaceutical and biotech process teams needing low extractable filters
- Semiconductor manufacturers filtering ultra-pure process liquids at high temperature
- Filtration distributors specifying replacements for OEM fluoropolymer cartridges
- System integrators designing systems for aggressive chemical duty
What It Fixes On The Line
- OEM fluoropolymer cartridges have long lead times and high unit cost
- Standard materials degrade in hydrofluoric acid, strong bases, or oxidizing gases
- Filter elements shed particles or fail under high temperature or pressure
- Extractables from elastomers or polymers contaminate high purity streams
- Existing housings cannot accept new cartridges due to mismatched dimensions or seals
Construction Detail
- Expanded PTFE membrane provides high particle removal efficiency and hydrophilic flow
- PFA core, cage, and end caps ensure structural integrity in aggressive fluids
- PFA encapsulated Viton O-rings resist chemical attack and maintain sealing
- Outside-in flow path retains captured solids during change-out
- All components are fluoropolymer, eliminating material compatibility concerns
- Designed to match standard OEM housing dimensions and adapter types
Materials Of Construction
- Expanded PTFE membrane for high particle removal and hydrophilic flow
- PFA support layer, core, cage, and end caps for chemical resistance
- PFA encapsulated Viton O-rings for seal integrity in aggressive fluids
- No adhesives, surfactants, or non-fluoropolymer components used
PFA Fluoropolymer Membrane Filter Cartridges Specifications
Every figure below comes from the manufacturer data for this series. Anything not listed here is not published and we will confirm it against your duty before you order.
| Series | PFA Fluoropolymer Membrane Filter Cartridges |
|---|---|
| Filter Medium | Expanded PTFE Membrane |
| Support Layer | PFA |
| Core and Cage | PFA |
| End Caps | PFA |
| O-rings | PFA encapsulated Viton |
| Max Forward Differential Pressure | 60 psi (4.14 bar) at 70°F (21.1°C) |
| Max Reverse Differential Pressure | 30 psi (2.07 bar) at 70°F (21.1°C) |
| Flow Pattern | Outside-in |
| Material of Construction | All fluoropolymer |
| Dimensional Equivalent To | Common OEM series (confirm housing model for match) |
PFA Fluoropolymer Membrane Filter Cartridges In Detail
Where It Is Installed
Filtration of hydrofluoric acid, nitric acid, and sulfuric acid in chemical processing
High temperature liquid processing above 100°C in semiconductor or pharmaceutical lines
Purification of aggressive solvents such as chloroform, 2-methyl, and isopropyl alcohol
Handling of strong alkaline solutions in industrial cleaning or chemical synthesis
Gas filtration with strong oxidizing agents where material stability is critical
How This Cartridge Is Built
Media Preparation
PTFE membrane expansion and lamination to PFA support layer
Pack Forming
PFA core and cage injection moulding to full cartridge length
Hardware Assembly
End cap and O-ring assembly using PFA encapsulated Viton
End Cap Bonding
Thermal bonding of end caps without adhesive
Configuration
Final inspection of seal integrity and dimensional accuracy
Inspection And Packing
Individual packaging with protective end caps
Checks Before It Ships
- Dimensional check of outer diameter, length, and adapter against ordered code
- Visual inspection of PTFE membrane for defects, gaps, or delamination
- O-ring compound and seating verification before packing
- Seal integrity test at 30 psi reverse pressure to verify no leakage
- Final check of PFA encapsulation on Viton O-rings for full coverage
What We Can Change For You
- Lengths available to match installed housing dimensions (confirm model)
- Micron ratings available based on PTFE membrane specification (confirm duty)
- O-ring compound selected as PFA encapsulated Viton for all configurations
- Adapter type matched to existing housing seat (round double O-ring or claw single O-ring)
- Private label printing and carton marking available for distributors
How It Compares With The Alternatives
| Standard PTFE membrane cartridges | PFA Fluoropolymer series offers higher temperature and pressure resistance, and better chemical stability in aggressive acids and bases |
|---|---|
| Pall PFA series | Dimensional equivalent to Pall PFA series, but with same fluoropolymer construction and no OEM branding |
| CUNO fluoropolymer cartridges | Same materials and performance, but replaces CUNO series without OEM lead time or cost |
| Standard polypropylene pleated cartridges | PFA series resists strong chemicals and high temperatures; polypropylene fails in hydrofluoric acid or oxidizing agents |
Installing And Running This Cartridge
- Confirm housing model, cartridge length, and adapter type before ordering
- Use only outside-in flow; reverse flow may damage the membrane
- Flush the housing before installing a new cartridge to remove settled solids
- Lift the cartridge vertically and keep it upright during change-out to retain captured particles
- Change out at the recommended interval or when differential pressure reaches 60 psi
PFA Fluoropolymer Membrane Filter Cartridges FAQ
Will this cartridge fit my existing OEM housing?
What micron ratings are available?
Can I use this in hydrofluoric acid?
How do I write the order code?
Can I get a sample before placing a production order?
Other Elements Buyers Compare With This One

SPP Series Depth Pleated Filter Cartridges
SPP series depth pleated filter cartridges are constructed with a single piece full length polypropylene media pack, an inner core and an injection mo
View SpecificationsPP Pleated Filter Cartridges
PP pleated filter cartridges are depth pleated cartridges with a single piece full length polypropylene media pack, an inner core, and an injection mo
View SpecificationsReading That Helps You Specify
How To Choose A Micron Rating For Cartridge Filters
Absolute versus nominal ratings, choosing from the stage you protect, and why rating drives change-out cost more than unit price.
Read GuideO-Ring Material Selection For Filter Cartridges
Choose EPDM, Viton, Buna, or Silicone o-rings based on fluid and temperature. All rated up to 80℃. Avoid mismatched materials to prevent failure.
Read GuideMatching Replacement Cartridges To Your Filter Housing
Find the right replacement cartridge by matching outer diameter, length, adapter, O-ring, and flow direction. We confirm fit based on your housing model and cur
Read GuideSend Us Your Housing Model And Duty
Send the housing model and the code on the element you use today and we will confirm whether PFA Fluoropolymer Membrane Filter Cartridges is the right match before you order.