Liquid filter cartridges and housings made in Jiangyan, Taizhou since 2009[email protected]+8618051183600
Finished high flow filter cartridges on the production floor

Home/Products/High Flow Filter Cartridges/HFPK Series High Flow Filter Cartridges Parker Equivalent

HFPK Series High Flow Filter Cartridges Parker Equivalent

6 inch high flow pleated cartridges in 40 inch and 60 inch lengths, 1 to 100 micron, 80 C, 3.5 bar. Dimensional equivalent to Parker Filtraman HFPK se

Overview

What The HFPK Series High Flow Parker Equivalent Does In Your Line

HFPK is a 6 inch large diameter high flow cartridge with a pleated polypropylene media pack, an inner core and an injection moulded outer cage. It runs outside-in, so dirt is captured on the outside of the pleat pack and stays there during change-out. One HFPK element replaces a bank of 2.5 inch cartridges, which is why plants fit it when the existing filter skid has run out of housing space. It is dimensionally equivalent to the installed Parker Filtraman HFPK series and drops into those housings without adapters.

Category: High Flow Filter Cartridges · Industries: Water Treatment And RO Systems Oil And Gas Operations Food And Beverage Plants

Labelled schematic of the HFPK Series High Flow Filter Cartridges Parker Equivalent showing construction and connection detail
Key Benefits

Why Buyers Pick This Element

  • One 6 inch element does the work of a bank of 2.5 inch cartridges and frees skid footprint
  • Large filtration area and high flow rate reduce pressure drop and extend change-out intervals
  • Outside-in flow path keeps captured solids on the cartridge when an operator lifts it out
  • Built-in handle enables fast and easy change-out without tools
  • Injection moulded outer cage takes the differential pressure without pleat collapse
  • Dimensional equivalent to the installed Parker Filtraman HFPK series so no piping or housing change is needed
Who It Is For

Buyers Who Specify This Cartridge

  • Water treatment plant engineers replacing OEM high flow cartridges on an existing skid
  • RO system integrators specifying prefiltration for new desalination or process water trains
  • Beverage and food plant maintenance teams standardising on one cartridge across lines
  • Filtration distributors who need an equivalent series to quote against OEM part numbers
Problems It Solves

What It Fixes On The Line

  • Cartridge change-out on a large skid takes hours because there are too many small elements
  • OEM high flow cartridges carry long lead times and high unit cost per replacement cycle
  • Filter housings are full and there is no floor space to add another vessel for more flow
  • Pleat packs collapse under differential pressure and shed captured solids back into the line
  • Solids fall off the element during change-out and contaminate downstream filtrate
Technical Features

Construction Detail

  • Vertical pleated construction that maximises effective filtration area per element
  • Single piece full length media pack with no joints along the cartridge
  • Inner core plus injection moulded outer cage for differential pressure strength
  • Outside-in flow path for contaminant retention during change-out
  • Built-in handle for fast and easy change-out without tools
  • Round double O-ring and claw single O-ring adapters to match installed housings
  • Absolute micron ratings from 1 to 100 micron across the same body
Materials

Materials Of Construction

  • Polypropylene filtration media, thermally bonded without adhesives or surfactants
  • Polypropylene inner core and injection moulded outer cage
  • EPDM O-rings for general water and hot water service
  • Viton O-rings for aggressive chemical and higher temperature duty
  • Buna O-rings for hydrocarbon and general industrial water
  • Silicone O-rings where a low extractable elastomer is preferred
Specifications

HFPK Series High Flow Filter Cartridges Parker Equivalent Specifications

Every figure below comes from the manufacturer data for this series. Anything not listed here is not published and we will confirm it against your duty before you order.

SeriesHFPK
Outer Diameter6 inch (152 mm)
Lengths40 inch, 60 inch
Micron Ratings1, 3, 5, 10, 20, 25, 50, 100 micron
MediaPolypropylene
Core and CagePolypropylene
O-ring OptionsEPDM, Viton, Buna, Silicone
Adapter OptionsS = Standard adapter, E = Extended adapter
Max Temperature80 C
Max Differential Pressure3.5 bar at 21 C
Recommended Change-out2.4 bar differential
Flow PatternOutside-in
Order Code ExampleHFPK-5-40-E-S
Application Scenarios

Where It Is Installed

RO pretreatment ahead of membrane racks in a desalination or demineralisation train

Cooling water side stream filtration where suspended solids foul heat exchangers

Beverage and food process water polishing before bottling or blending

Bulk chemical transfer where particulate must be removed at high flow with low pressure drop

Seawater and brackish water intake filtration ahead of cartridge or membrane stages

Manufacturing

How This Cartridge Is Built

Media Preparation

Media extrusion and pleating to a fixed pleat pitch

Pack Forming

Vertical pleat pack forming to full cartridge length in one piece

Hardware Assembly

Core insertion and injection moulded cage assembly

End Cap Bonding

Thermal end cap bonding without adhesive

Configuration

O-ring and adapter fitting to the ordered configuration

Inspection And Packing

Flush, drain and individual packing

Quality Control

Checks Before It Ships

  • Dimensional check of outer diameter, length and adapter against the ordered code
  • Pleat pack inspection for collapse, gaps and end cap bond integrity
  • Differential pressure check against the 3.5 bar at 21 C rating
  • O-ring compound and seating verification before packing
Customization

What We Can Change For You

  • Length combinations from 40 inch to 60 inch to match the installed housing
  • Micron rating selected from 1 to 100 micron for the duty
  • O-ring compound chosen from EPDM, Viton, Buna or Silicone
  • Standard adapter or extended adapter to match the existing seat
  • Private label printing and carton marking for distributors
Comparison

How It Compares With The Alternatives

2.5 inch pleated cartridgesHFPK cuts element count and change-out labour, but the initial cartridge cost per piece is higher
HFPK series with extended adapterSame 6 inch envelope; HFPK with standard adapter fits most housings, extended adapter for deeper seat or longer seal
Bag filtersHFPK holds a tighter absolute rating and does not bypass at the seal, but a bag is cheaper for coarse duty
OEM branded high flow cartridgesSame dimensions and fit at a lower landed cost and shorter lead time, without the OEM warranty documentation
Use Guide

Installing And Running This Cartridge

  • Confirm housing bore, seat type and cartridge length before ordering; the adapter code must match
  • Start clean differential pressure logging from day one so change-out is data driven
  • Change out at 2.4 bar differential rather than waiting for the 3.5 bar maximum
  • Do not exceed 80 C; select Viton O-rings if the duty runs warm or carries solvents
  • Flush the housing before fitting a new element so settled solids do not load it immediately
  • Lift the element vertically and keep it upright so captured solids stay on the pleat pack
FAQ

HFPK Series High Flow Filter Cartridges Parker Equivalent FAQ

Will HFPK fit my existing Parker Filtraman HFPK housings?
Yes. HFPK is built to the same 6 inch outer diameter and the same 40 inch and 60 inch lengths, with standard or extended adapter options. Send us the housing model and the cartridge code you buy today and we will confirm the match before you order.
What micron ratings can I get?
1, 3, 5, 10, 20, 25, 50, and 100 micron in the same cartridge body. For RO pretreatment most plants run 5 or 10 micron; for cooling water side streams 20 to 50 micron is more common.
What is the maximum operating temperature and pressure?
80 C maximum temperature and 3.5 bar maximum differential pressure at 21 C. We recommend changing the element at 2.4 bar differential to avoid running the pleat pack at its limit.
Which O-ring should I choose?
EPDM for general and hot water, Viton for aggressive chemicals and higher temperature, Buna for hydrocarbon and general industrial water, Silicone where a low extractable elastomer is preferred. Tell us the fluid and we will advise.
How do I write the order code?
Series, micron, length, O-ring, adapter. HFPK-5-40-E-S is a 5 micron, 40 inch cartridge with Viton O-rings and a standard adapter.
Can I get a sample before placing a production order?
Yes. Message us on WhatsApp with your housing model, current cartridge part number and duty, and we will quote a sample quantity with the matching configuration.

Send Us Your Housing Model And Duty

Send the housing model and the code on the element you use today and we will confirm whether HFPK Series High Flow Filter Cartridges Parker Equivalent is the right match before you order.