We reply to enquiries within 12 hours · Mon-Sat 08:30-18:00 GMT+8[email protected]+86 18155106856
Solar Inverters and PCS

Growatt MID 25/30/40KTL3 On Grid Inverter

Growatt MID 25/30/40KTL3 On Grid Inverter is a grid-tied string inverter rated at the rating listed in the specification table, built for rooftop and ground mount PV plants that export directly to the utility with no storage stage.

Key Benefits

What This Product Changes On Your Project

  • Multiple MPP trackers, so roof sections at different pitches and orientations do not have to share one string
  • Transformerless topology keeps conversion loss and unit weight down at this power class
  • Grid protection built in - anti-islanding, insulation monitoring, residual-current monitoring and surge protection
  • Outdoor-rated enclosure that can be wall-mounted next to the array instead of inside a plant room
  • Standard monitoring interfaces so the plant reports into existing supervisory software

Application Scenarios

  • Off-grid and weak-grid sites running PV, battery and generator together
  • Industrial microgrids switching between grid-tied and island operation
  • Commercial rooftop PV exporting to the utility under a net-metering or feed-in scheme
  • Ground-mount arrays where several sub-arrays share one inverter station
  • Solar-plus-storage retrofits on sites that already have PV

Who It Is For

  • PV installers and EPC contractors specifying inverters for grid connection approval
  • Distributors carrying inverter lines for commercial rooftop work
  • System integrators building solar-plus-storage and microgrid systems
  • Asset owners standardising on one inverter platform across a portfolio

Problems It Solves

  • Roof geometry that forces strings of different lengths and orientations onto one inverter
  • Grid codes that reject an installation without export limitation and reactive power control
  • Conversion loss and heat derating that quietly erode plant yield in summer
  • Separate PV and storage conversion stages that double the failure points and the commissioning time

Technical Features

  • Smart cooling with temperature-based derating rather than abrupt shutdown
  • RS485 and wireless monitoring interfaces
  • Independent MPP trackers, each tracking its own string set
  • Transformerless conversion topology
  • DC switch, DC reverse-polarity protection and surge protection on both DC and AC sides
Specifications

Published Specification Data

These figures come from the manufacturer datasheet for this model. Where a value you need is not listed, ask for the full datasheet rather than assuming a typical figure.

BrandGrowatt

Quality Control

  • Serialised traceability from cell batch to finished unit
  • Packing inspection and photo record before container loading
  • Incoming inspection of cells, power electronics and structural parts before assembly
  • Capacity and internal-resistance grading so cells within a pack are matched
  • Full-function test on every finished unit, not a sample from the batch

Customization Options

  • Customer branding on packaging and documentation
  • Grid code and AC voltage configuration for the destination market
  • Monitoring accessory selection - Wi-Fi, GPRS or RS485 to an existing logger
  • DC connector type to match the array already specified
Comparison

How It Compares With The Alternatives

Separate PV inverter plus battery inverterOne conversion stage means one set of wiring, one monitoring platform and one warranty, at the cost of less freedom to mix brands later.
A microinverter arrayString conversion costs less per kW at commercial scale; microinverters win on complex shading and per-module monitoring.
An oversized single inverterSeveral MPP trackers serve differently oriented roof sections without splitting the array, so one unit covers what would otherwise need two.
Use Guide

Getting This Product Right On Site

  1. 1

    Verify the array string voltage against the MPPT window at the site's record low temperature

  2. 2

    Select the grid code for the destination market before energising

  3. 3

    Mount out of direct afternoon sun and leave the clearance the manual specifies for airflow

  4. 4

    Commission the monitoring interface at the same visit, not as a follow-up trip

  5. 5

    Record the firmware version so a later fleet update can be planned

Growatt MID 25/30/40KTL3 On Grid Inverter - Buyer Questions

Does the inverter support export limitation
Export limitation and reactive power control are the two settings most utility approvals ask for. Confirm the required scheme in your enquiry so the unit ships configured for it.
What monitoring is included
Standard interfaces are listed in the specification table. Wireless and cellular loggers are ordered as accessories where the site has no local network.
What is the warranty term
The standard term and the available extension are confirmed in writing with the quotation, as they vary by model and market.
How is the inverter packed and shipped
Individually boxed and palletised for container shipping. We confirm pallet quantity and container loading plan with the order.
Which grid codes can this inverter be set to
Grid code is selected at commissioning for the destination market. Tell us the country and utility and we will confirm the setting is supported before shipment.
Can this inverter work with batteries from another brand
Battery compatibility depends on the communication protocol. Send the battery model you intend to pair and we will confirm the handshake rather than leave it to the site to find out.

Request A Quote For Growatt MID 25/30/40KTL3 On Grid Inverter

Tell us the quantity, the destination market and the application. We reply within 12 hours with lead time, certification and pricing.