Skip to content
Shandong Jinhao Electrical Technology Co., Ltd. · Linyi Shandong China
High voltage substation switchyard with busbar structures and insulator strings
Industry Application

Substations And Switchyards

Substation yards concentrate equipment, heat and pollution in a small footprint. Strings here are short, heavily loaded and surrounded by structures that make washing and replacement awkward.

Home/Industries
Pain Points

What Goes Wrong In This Sector

  • Deposit builds fast in a confined yard with transformer and cooling air movement
  • Replacement inside an energised yard means long clearance procedures
  • Busbar and dead-end strings carry higher mechanical loads than line suspension strings
  • Radio interference and corona are scrutinised more closely near control buildings
Requirements

What Buyers Here Actually Need

  • High creepage in a short string where discs cannot simply be added
  • 160 kN class ratings for tension and dead-end applications
  • Controlled corona extinction voltage and RIV performance
  • Profiles that resist the specific deposit chemistry of the yard
Recommended Models

Discs Suited To Substations And Switchyards

Selected on mechanical rating, creepage distance and profile geometry for the conditions described above.

U160BLT three-alternating profile toughened glass insulator with three stepped shed diameters
Three-alternating Profile

U160BLT · 160 kN

A 160 kN three-alternating disc with 155 mm spacing, 330 mm diameter and 550 mm creepage, weighing 8.9 kg. The longest creepage…

Creepage 550 mm Ø 330 mm Coupling 20
U70BLP anti-fog profile toughened glass insulator with deep ribs and 280 mm diameter
Anti-Fog Profile

U70BLP · 70 kN

A 70 kN anti-fog disc with 146 mm spacing, 280 mm diameter and 450 mm creepage, weighing 5.3 kg. Deep under-ribs hold a dry band…

Creepage 450 mm Ø 280 mm Coupling 16
U160BSV two-alternating profile toughened glass insulator with alternating shed diameters
Two-alternating Profile

U160BSV · 160 kN

A 160 kN two-alternating disc with 155 mm spacing, 300 mm diameter and 450 mm creepage, weighing 8.4 kg. Alternating shed diameters…

Creepage 450 mm Ø 300 mm Coupling 20
How We Deliver

Support Across The Project Cycle

From selection through manufacture to on-site guidance, handled by the same engineering team.

Pre-Sales Technical Consultation

Selection starts from your line conditions, not from our catalogue.

Customized Design And Manufacturing

When the standard disc does not fit the site, we develop one that does.

Production And Quality Assurance

Defective shells are removed in our furnace, not on your tower.

Logistics And Global Delivery

Export packing and documentation handled as part of the order, not as an afterthought.

Project Record

Work In This Sector

Answers

Substations And Switchyards Questions

Which profile suits a confined switchyard?

Where the string is short and discs cannot be added, buy creepage inside the disc. The U160BLT gives 550 mm and the U70BLP gives 450 mm at their respective mechanical ratings.

What corona and RIV performance do your discs have?

Corona extinction voltage of 18/22 kV pin to cap and a maximum RIV of 50 microvolt at 1000 kHz with a 10 kV RMS to ground test voltage, across the listed range.

Do you supply assembled strings for substation use?

Yes. We supply complete sets covering discs, coupling fittings and assembly strings.

Tell Us About The Route

Voltage, mechanical load, pollution class and quantity. We will size the string and confirm what we can deliver and when.