Tianjin Huayan Medical Equipment Co., Ltd. Established 2008 · Tianjin China
CNC machining line on the production floor at the Huayan Medical plant in Tianjin
Micro-Pressure Decoction

Micro Pressure Herb Decoction and Packing Machine HVR2000

The HVR2000 is a micro-pressure TCM herb decoction and packing machine that boils two herbal prescriptions simultaneously and seals finished liquid into single-dose pouches on a...

Product Overview

What the HVR2000 Is Built To Do

The HVR2000 is a micro-pressure TCM herb decoction and packing machine that boils two herbal prescriptions simultaneously and seals finished liquid into single-dose pouches on a single frame. Built for TCM hospital pharmacies, clinics, and health centres, it features two 20,000 ml glass pots, automated switching from low fire to high fire, and a visible piezometer for real-time pressure monitoring. An integrated heat-seal packing head rated at 8 pouches per minute allows one operator to complete the entire decoction and packaging workflow without transferring hot liquid manually.

At A Glance
  • Model: HVR2000
  • Series: Micro-Pressure TCM Herb Decoction Machine
  • Brand: Huayan Medical
  • Decoction glass pots: 2 pots
  • Capacity per pot: 20,000 ml per pot
  • Decoction power: 1800 W per pot
Key Benefits

Why Buyers Specify the HVR2000

  • Two independent 20,000 ml glass pots run separate prescriptions simultaneously without any liquid cross mixing
  • Decoction and pouch sealing combined on one 1260 mm frame eliminates hot liquid transfer across dispensary rooms
  • Micro-pressure extraction improves herbal active ingredient extraction while reducing overall processing time and heating energy
  • Visible piezometer on the glass cylinder provides direct real-time pressure monitoring throughout the decoction cycle
  • Automated switching from low fire to high fire follows traditional extraction principles without manual operator intervention
  • Integrated heat-sealing unit produces hermetically sealed 50 to 250 ml pouches ready for clean patient consumption
Problems It Solves
  • Open-pot boiling demands constant staff supervision to manage fire transitions between slow and strong heating stages
  • Manual transfer of boiling herbal liquid between separate pots and packaging units causes spill and scald risks
  • Unregulated boiling temperatures and open heating pots lead to inconsistent herbal extraction quality across batches
  • Patients frequently fail home decoction regimens when required to boil complex raw herb bags for hours
  • Maintaining separate decoction burners and packaging sealers consumes excessive dispensary floor space and requires multiple workers
Where It Is Used

Where the HVR2000 Is Used

Application Scenarios
  • TCM hospital pharmacy preparing outpatient prescriptions in sealed single-dose liquid pouches for daily dispensing
  • TCM acupuncture clinic offering ready-to-drink herbal medicine directly to patients undergoing scheduled treatment courses
  • Community TCM clinic standardising raw herb boiling and sanitary pouch packing on a compact footprint
  • TCM health centre boiling and packaging customized herbal tonics and health beverages for clients
  • Beverage and herbal tea workroom boiling and hermetically pouching plant extracts or fruit juices in batches
Who It Is For
  • TCM hospital pharmacy managers upgrading from open-pot boiling to an integrated micro-pressure extraction and packaging station
  • Private clinic owners who want patients to receive clean ready-to-drink pouches rather than raw herb packages
  • Health centre supervisors requiring consistent boiling temperature control and sanitary single-dose pouch production
  • Medical equipment distributors supplying registered TCM clinics, acupuncture wards, and hospital pharmacies overseas
  • Herbal tea producers seeking an automated combined system for batch boiling and single-serve pouch packing
Technical Features

Inside the HVR2000

  • Two independent 20,000 ml glass decoction pots powered at 1800 W per pot
  • Integrated 800 W heat-seal packaging section delivering an output rate of 8 pouches per minute
  • Micro-pressure extraction capability with a built-in piezometer for visible pressure monitoring on the cylinder
  • Automated heating power regulation executing programmed transitions from slow fire to strong fire
  • Computerized control interface displaying visible cycle times alongside clear audible warning signals between stages
  • Temperature setting range between 100 and 199 degrees Celsius adjusted with up and down roller controls
  • Pouch length adjustable between 95 and 180 mm at a fixed pouch width of 100 mm
  • Liquid pouch filling volume adjustable from 50 to 250 ml to accommodate varied prescription dosages
  • Comprehensive safety guarding and hermetic heat-sealing film enclosure to maintain safe dispensary operating conditions
Materials and Build
  • Two high-clarity glass decoction pots allowing visual inspection of boiling action and fluid volume
  • Stainless steel working surfaces and frame engineered for sanitary wipe-down cleaning in medical dispensaries
  • Hermetic heat-sealable TCM liquid packaging film supplied as a roll consumable
Specifications

Micro Pressure Herb Decoction and Packing Machine HVR2000 Technical Data

Figures below are taken from the manufacturer data sheet for this model. Tell us your local voltage and dosing practice and we will confirm the build before the order.

ModelHVR2000
SeriesMicro-Pressure TCM Herb Decoction Machine
BrandHuayan Medical
Decoction glass pots2 pots
Capacity per pot20,000 ml per pot
Decoction power1800 W per pot
Heat seal packing power800 W
Total power4,500 W
Dosage of decoction2 to 15 pairs per pot x 2 pots
Package capacity8 pouches per minute
Pouch dimensions95 to 180 mm length x 100 mm width
Pouch volume50 to 250 ml, setting available
Temperature setting range100 to 199 degrees Celsius
Pressure monitoringVisible piezometer on glass cylinder
Rated voltage220 V, special customization available
Dimensions1170 mm height x 1260 mm width x 540 mm length
Net weight130 kg
How It Is Made and Checked

How the HVR2000 Is Built and Checked

How This Model Is Built and Tested
  • Load weighed raw herbs into non-woven bags and place them into the 20,000 ml glass pots
  • Set target decoction time and temperature between 100 and 199 degrees Celsius on the computerized panel
  • Initiate the micro-pressure cycle as automated heating shifts systematically from low fire to high fire
  • Monitor extraction conditions using the visible piezometer mounted on the glass cylinder assembly
  • Listen for the audible stage warning before transferring boiled liquid directly into the sealing assembly
  • Hermetically heat seal and cut single-dose pouches sized between 50 and 250 ml for distribution
Quality Control
  • Operational cycle testing conducted on heating, pressure maintenance, and pouch sealing prior to dispatch
  • Piezometer pressure tracking accuracy and glass cylinder seals inspected under active working conditions
  • Packaging section heat-sealing integrity and volumetric pouch fill verified on each completed unit
  • Manufactured within a production facility certified to ISO 9001 and ISO 13485 medical standards
  • Apparatus electrical safety and enclosure protection verified under applicable CE conformity standards
Certification Held By The Plant
ISO 9001ISO 13485CE markingTested as a complete cycle before packing
Customization

Building the HVR2000 To Your Practice

  • Special electrical voltage engineering available on request for facilities operating outside 220 V supply
  • Pouch length and volumetric dosage settings configured to align with specific clinical prescription protocols
  • Control interfaces and operational documentation provided with English labeling for international operators
  • Ongoing consumable support including custom-sized non-woven herb bags and hermetic heat-seal packing film rolls
Use Guide
  • Install the 130 kg unit on a level floor with access to a grounded 220 V power source
  • Place weighed medicinal herbs into non-woven extraction bags and add measured water to the glass pots
  • Adjust temperature parameters between 100 and 199 degrees Celsius using the up and down roller keys
  • Verify the cylinder seal and check piezometer readings as heating power switches automatically between fire stages
  • Feed heat-sealable packaging film into the packaging section and run a dry test pouch before filling
  • Initiate liquid pouch sealing upon hearing the audible cycle alert, dispensing measured doses from 50 to 250 ml
  • Flush the glass pots and internal liquid conduits with clean water after daily dispensary operations finish
Comparison

How the HVR2000 Compares

An honest read on where this model wins and where another one suits you better.

vs Normal-pressure herb decoction machine HCK2000
The HCK2000 operates at normal atmospheric pressure with three pots, whereas the HVR2000 uses two pots under micro pressure with a piezometer for deeper herbal extraction.
vs Airtight herb decoction machine HYY13L
The HYY13L decocts inside a sealed chamber but lacks packaging capabilities, whereas the HVR2000 integrates micro-pressure boiling and single-dose pouch packaging on one frame.
vs Automatic twice decoction machine HYLK22X
The HYLK22X executes two consecutive extraction cycles with automatic herb-liquid separation, while the HVR2000 provides a faster single-cycle micro-pressure decoction and packing process.
vs Separate open boiling stoves and benchtop sealers
Separate stoves require manual liquid transfers and larger working areas, while the HVR2000 consolidates micro-pressure boiling and automated pouching on a single 1260 mm footprint.
Questions Buyers Ask

HVR2000 Questions and Answers

What is the standard production lead time and payment term for the HVR2000?
Lead time is generally about 6 days after payment is received by T/T, depending on the required model configuration and quantity.
Can the two glass pots run different herbal formulas at the same time?
Yes. The HVR2000 features two independent 20,000 ml glass pots, allowing two separate prescriptions of 2 to 15 pairs each to decoct simultaneously without cross mixing.
What pouch dimensions and liquid volumes can the packaging unit produce?
The packaging section seals up to 8 pouches per minute. Pouch length adjusts from 95 to 180 mm at 100 mm width, with liquid volumes setting between 50 and 250 ml.
What electrical voltage and power supply are required to operate this machine?
Standard supply is 220 V with total power consumption of 4,500 W (1800 W per decoction pot and 800 W for sealing). Special voltage customization is available on request.
How is internal pressure tracked during the micro-pressure decoction cycle?
The machine includes a visible piezometer mounted on the glass cylinder assembly, enabling the operator to observe operating pressure directly throughout heating.
What warranty and spare parts terms apply to international shipments?
Huayan provides a one-year free warranty from qualified commissioning with free part replacements. Standard wear parts are included directly in the shipment.

Ready to price the HVR2000

Send us your local voltage, your session volume and the space you have. A price and a full specification sheet for the HVR2000 come back within twelve hours.