Jinan Weihua Machinery & Equipment Co., Ltd · Jinan Shandong China
Wood panel engraved with a CO2 laser
Knowledge Centre

CO2 Laser Power Supply

Published 2020-07-15 by the Weihua Laser engineering desk.

Why The Power Supply Is The First Check

When a CO2 machine stops producing light, the fault usually sits with the tube or the MYJG power supply. Testing the supply first prevents buying a new tube when the electronics are the actual problem. The MYJG unit is known for high efficiency and excellent power stability, providing the high voltage needed to energize the laser tube.

Preparing The Machine For Measurement

Install the laser tube into the machine, even if you suspect it is damaged. The circuit must be closed for the supply to register current. Turn on the main electricity. The MYJG power supply display will show L 0, indicating the unit is receiving power and is ready for the pulse test.

Running The Pulse Current Test

Press Pulse on the laser machine panel to send a signal through the supply. Observe the current value displayed on the power supply unit. The MYJG supply features a user-friendly control interface that allows operators to monitor this output directly. This step isolates whether the supply is generating the necessary high voltage.

Reading The Values For A Reci W2 Tube

Set your laser power to 80 percent. A normal current value on the power supply should be approximately 25 mA. Next, set your laser power to 50 percent. The normal current value should drop to approximately 10 mA. These figures apply specifically when testing with a Reci W2 laser tube.

Interpreting The Results

If your test result is near the normal values, your CO2 laser source and power supply are functioning correctly. If the current does not reach these levels, the power supply is likely damaged and needs replacement. The compact and lightweight design of the MYJG supply makes integration and replacement straightforward for maintenance teams.

Machines Mentioned Here

All machines

Vinyl Cutting Plotters

Contour Cutting Plotter

The Contour Cutting Plotter series includes the WH500, WH880, and WH1380 models, designed for cutting vinyl, reflective film, and soft organic...

Buyer Questions

Questions On This Topic

What current should I see at 80 percent power?
For a Reci W2 laser tube, the MYJG power supply should show a normal current value of approximately 25 mA at 80 percent power.
What current should I see at 50 percent power?
For a Reci W2 laser tube, the MYJG power supply should show a normal current value of approximately 10 mA at 50 percent power.
Do I need to install the tube to test the supply?
Yes. You must install the laser tube to the machine, even if the tube is damaged, to complete the circuit for the test.
What does L 0 mean on the display?
L 0 indicates that the power supply is turned on and receiving electricity, ready for you to press the Pulse button.
Is the MYJG power supply compatible with other tubes?
The test values provided are for a Reci W2 tube. Other tubes may have different normal current ranges, so consult the tube specifications.
What if the current is lower than expected?
If the test result is not near the normal value, the CO2 laser power supply is likely damaged and requires replacement.

Still Not Sure Which Machine Fits

Send the material and the thickness. We answer with a model and the settings that go with it, not a catalogue.