Feel The Life With Light · LED manufacturer since April 2010
C&R Group
Products
Industries
Solutions
Resources

Request A Quote

LED Tube Lights

1500mm T8 LED Tube Light

Part number CRTB-015

1500mm T8 LED Tube Light sits in our LED Tube Lights range as the LED retrofit tube built for fluorescent fittings in warehouses, workshops, offices and retail. It is specified with input of AC100-240V, or AC220V, AC110V, power factor of 0.85~0.95 and cover of Aluminum cover. Both diameters matter, because buildings rarely use just one. It is catalogued as CRTB-015.

Key Benefits

What This Model Gives You

Power factor 0.85~0.95

A published power factor is what lets an electrical contractor size the circuit properly.

Against the other diameter in the same length

T8 suits older wider fittings; T5 suits the slimmer fittings installed more recently.

Against the fluorescent tube it replaces

No starter, no flicker on ignition and far lower energy for comparable light.

Against a complete new LED batten fitting

Retrofit into existing fittings avoids the labour and disruption of changing luminaires.

Specifications

Technical Data For 1500mm T8 LED Tube Light

Every figure below is taken from the manufacturer's specification for this model. Where a value is not listed it is not published, and we will confirm it against current production before you order.

Item NoCRTB-015
InputAC100-240V, or AC220V, AC110V
Lenght1500mm
CoverAluminum cover
LED Current15-18mA
Power Factor0.85~0.95
CRI (color Rendering Index)74-90 Ra
Power Consumption18w for 1500mm
Technical Features

How It Is Built

  • Electrical input: AC100-240V, or AC220V, AC110V
  • Power factor: 0.85~0.95
  • 1000 Hours Lighting Decay: less than 3%.
  • 1200mm LED T8 tubes used in the laboratory of the factory.
Who It Is For

Buyers This Model Suits

  • Electrical wholesalers holding retrofit stock
  • Warehouse, workshop and retail operators
  • Energy service companies delivering lighting upgrades
  • Facilities and maintenance contractors

Application Scenarios

  • Warehouse and workshop fluorescent replacement
  • Retail back-of-house and stockroom lighting
  • Office ceiling battens and surface fittings
  • School and public building maintenance programmes
Problems It Solves

Objections This Model Removes

01

Site surveys turn up fittings nobody documented

02

Tube quality varies between batches and between suppliers

03

Ballast compatibility is discovered by the electrician rather than by the buyer

04

A lamp change programme stalls because one length is out of stock

Manufacturing Process

How This Product Is Made

Production runs at our Shenzhen plant, Shenzhen Chiclits Technology Co., Ltd..

Tube body preparation and end cap fitting

SMD LED board population along the full length

Driver assembly and internal wiring

Electrical test, output check and protective packing

Quality Control

What Gets Checked

  • Length and diameter verification against the part number
  • Output and uniformity check along the tube
  • End cap retention and electrical safety test
  • Packing drop test for transit protection
Customisation

What You Can Change

  • Carton quantity and packing format for your warehouse
  • Length selected from 600mm, 900mm, 1200mm or 1500mm
  • T5 or T8 diameter
  • Colour temperature selected at order stage

Certification

Our LED bulb line holds CE (LVD) and RoHS certificates issued by Shenzhen BST Technology, with the numbers published on our Trust page. Ask us in writing for the certification position on this specific model before you quote it into a regulated market - we will tell you what is held and what is not.

See our certificates

Comparison

How It Compares With The Alternatives

Compared withWhat changes
A complete new LED batten fittingRetrofit into existing fittings avoids the labour and disruption of changing luminaires
The other diameter in the same lengthT8 suits older wider fittings; T5 suits the slimmer fittings installed more recently
The fluorescent tube it replacesNo starter, no flicker on ignition and far lower energy for comparable light
Use Guide

Getting It Right On Site

01

Change tubes in a full run rather than individually for consistent appearance

02

Keep the protective packing until the tube is at the fitting

03

Survey the building for both lengths and diameters before ordering

04

Tell us the ballast arrangement so we can confirm the correct version

Questions Buyers Ask

1500mm T8 LED Tube Light Questions

Do I need T5 or T8?

Measure the diameter of the existing tube. T8 is the wider, older standard; T5 is slimmer. Both are made here in this length.

How are the tubes packed?

Packed to protect the length in transit. Confirm carton quantity with us for this length.

Will this work with my existing ballast?

It depends on the ballast already installed. Tell us what is in the fitting and we will confirm the correct version before you order.

Can the tubes be mixed with panels on one order?

Yes. Tubes, panels, downlights and bulbs ship from the same plant on the same documentation.

Which tube lengths do you make?

600mm, 900mm, 1200mm and 1500mm, in both T5 and T8. Not every length is held in both diameters at all times - ask us to confirm against current stock.

What is the minimum order quantity and lead time for this model?

Both depend on the configuration, the packaging and the quantity, and neither is published as a blanket figure. Send us the model and quantity by email and we will confirm in writing.

Get Pricing For 1500mm T8 LED Tube Light

Send the quantity and destination market. We reply with pricing, packaging options, lead time and a written position on certification.