Medical Equipment and Accessories Manufacturer in Shenzhen Since 2003 Tel 0086-755-23247025 [email protected]
Home›Products›Reusable SpO2 Sensors›Datex›Datex Silicone Softtip SpO2 Sensor
Model RSDB014

Datex Silicone Softtip SpO2 Sensor

Datex Silicone Softtip SpO2 Sensor (RSDB014) is built to mate with the Datex connector standard used on Datex patient monitors. Supplied with a 2.7 m cable. Ronseda lists 19 compatible monitor models for this part, starting with (Datex-Ohmeda) AS/3.

Reusable SpO2 Sensors · Datex

ModelRSDB014
Product typeReusable SpO2 sensor
Monitor compatibilityDatex
Cable length2.7 m cable
Compatible monitors(Datex-Ohmeda) AS/3, CS/3, CH/S, CH/2S, CH-RS, CG/2S, Cardiocap I / II /5, Capnomac Ultima, Light Monitor, M-Estpr, Oscar II, OSP-200 and others
Warranty12 months after shipment
Price basisFOB Shenzhen; CFR or CIF quoted on request
Country of manufactureChina
Overview

Product Overview

As listed by the manufacturer

  • Datex-Ohmeda Silicone Softtip SpO2 Sensor
  • 10 holes
Value

What It Solves and Why It Is Worth Buying

Problems it solves

  • A ward rarely standardises on one monitor brand. Sensors wear out at the cable strain relief long before the monitor does, and original-brand replacements are priced per bed and often discontinued for older monitors still in daily use.
  • When a Datex monitor stays in service past its accessory supply window, the ward is left sourcing parts one at a time.
  • Stock items ship within one week of cleared payment, which keeps a replacement inside the service window.

Key benefits

  • One supplier covers every connector style on the ward, so spares arrive in a single shipment instead of being chased brand by brand.
  • A published compatibility list of 19 monitor models lets the buyer confirm fit before the order rather than after delivery.
  • Warranty runs 12 months after shipment, and returns are accepted for quality reasons inside that period.
  • OEM and ODM versions of this part are available when a distributor needs its own labelling.
Specification

Technical Features

  • 7M Long Cable
Compatibility

Compatible Monitor Models

  • (Datex-Ohmeda) AS/3
  • CS/3
  • CH/S
  • CH/2S
  • CH-RS
  • CG/2S
  • Cardiocap I / II /5
  • Capnomac Ultima
  • Light Monitor
  • M-Estpr
  • Oscar II
  • OSP-200
  • Satlite Trans
  • Satlite TransPlus
  • System 5
  • ULTS00
  • ULTSIO
  • ULTSVI
  • ULTSVO

Listed by Ronseda for this part number. If your monitor is not on the list, send the model and a photograph of the socket and we will confirm before you order.

Application

Who It Is For and Where It Is Used

Who it is for

  • Hospital biomedical engineering teams, monitor service companies and distributors who keep patient monitors of mixed makes running from one shelf of spare sensors.
  • Specifically, any department running Datex monitors that needs a matched replacement rather than a universal adapter.
  • Distributors and dealers who consolidate a mixed accessory list into one shipment from one factory.

Application settings

  • General wards and inpatient beds
  • Operating theatres and recovery
  • Emergency departments and ambulances
  • Outpatient and day-surgery clinics
Use guide

Use and Handling Guide

  1. Check the monitor socket against the part before connecting; do not force a partly seated plug.
  2. Inspect the cable along its whole length for cuts, kinks and exposed conductor before each use.
  3. Route the cable clear of bed rails and trolley wheels; most failures start as a crush at the strain relief.
  4. Clean with the agent named in the monitor manual; do not immerse the connector or autoclave the assembly.
  5. Replace the part when the trace becomes intermittent as the cable is flexed near the connector.
Buying terms

Quality Control Customisation and Terms

Quality control

Production runs under the factory quality control system and every shipment is inspected before it leaves Shenzhen.

Customisation

OEM and ODM services are available according to customer requirements. On accessory lines that includes specified connectors, cable lengths and customer labelling.

Certification

Certificate numbers and scopes are supplied on request with the quotation. We do not publish certification claims we cannot evidence.

Comparison

How It Compares With The Rest Of The Range

Datex Adult Fingerclip SpO2 SensorSame family, model RSDS014.
Datex Ohmeda SpO2 Sensor Adapter CableSame family, Round 10Pin termination and 2.4 m cable.
FAQ

Questions About Datex Silicone Softtip SpO2 Sensor

Which monitors does the Datex Silicone Softtip SpO2 Sensor fit?
Ronseda lists it against (Datex-Ohmeda) AS/3, CS/3, CH/S, CH/2S, CH-RS, CG/2S, Cardiocap I / II /5, Capnomac Ultima and 11 further models. If your monitor is not on that list, send the model name and a photograph of the socket and we will confirm before you order.
Is another cable length available?
The standard build is 2.7m long cable. Other lengths are made to order under OEM terms; state the length you need when requesting a quote.
What warranty applies?
12 months after shipment. Returns are accepted for quality reasons within the warranty period, excluding misuse, negligence or accident. Contact sales for confirmation before returning anything.
What are the payment and delivery terms?
FOB Shenzhen; CFR or CIF quoted on request. 100% T/T in advance or Western Union preferred; irrevocable L/C at sight accepted. Shipment is arranged within one week of cleared payment when the item is in stock, by DHL, UPS, FedEx or a courier you nominate.
Can I order a sample first?
Yes. Samples are available once sample charges are received, and for accessories the sample charge is refunded when the order is confirmed.
Do you supply this under our own brand?
Yes. OEM and ODM versions are available, including customer labelling and packaging. Send your artwork and quantity and we will quote against it.

Request a quotation for Datex Silicone Softtip SpO2 Sensor

Quote reference RSDB014. Send the quantity and destination port and we reply with the price basis, packing detail and lead time.