ACB

ACB

The ACB is a three- or four-pole, fixed or draw-out type circuit breaker for AC 50Hz/60Hz systems with rated voltages...

Product Overview

What This Model Does

The ACB is a three- or four-pole, fixed or draw-out type circuit breaker for AC 50Hz/60Hz systems with rated voltages up to 690V and rated currents from 630A to 6300A. It provides overload, short-circuit, under-voltage, and single-phase earth fault protection for power distribution in industrial, commercial and high-rise building applications. The breaker is built to IEC60947-2 and GB14048.2, and includes intelligent protection with selectable trip types and communication-ready controller options. It is suitable for use in power stations, factories, mines (for 690V), and intelligentized buildings where selective protection and reliable power continuity are required.

Key Benefits

  • Protects high-current circuits up to 6300A with short-circuit breaking capacity up to 120KA
  • Supports both fixed and draw-out configurations for flexible installation and maintenance
  • Intelligent controller options (L, M, H types) allow for selective protection and remote monitoring
  • Reduces unnecessary power outages through intelligent trip logic and selective coordination
  • Meets CCC certification across the entire series for compliance in regulated markets
  • High contact system stability with parallel connection and contact gap over 18mm to reduce dynamic forces
ACB circuit breaker in fixed type configuration on a panel board
ACB circuit breaker in fixed type configuration on a panel board

Who It Is For

  • Electrical panel builders integrating high-capacity breakers into main distribution boards
  • Industrial and mining facility engineers specifying reliable protection for 690V systems
  • Building contractors and EPCs installing ACBs in high-rise or commercial buildings
  • Power station operators needing draw-out type breakers for safe maintenance
  • OEMs developing switchgear systems that require CCC-certified, intelligent ACBs with communication options

Problems It Solves

  • A large industrial load trips the main breaker, causing a full site blackout instead of isolating only the faulty circuit
  • Maintenance teams must de-energize entire systems to replace a breaker, increasing downtime
  • Lack of selective protection leads to repeated outages during minor faults
  • No communication capability prevents integration with building management or SCADA systems
  • Non-compliant or uncertified breakers cannot be used in regulated markets like China’s CCC zone

Application Scenarios

  • Main distribution boards in industrial plants with high load currents and need for selective tripping
  • Power supply systems in mines and factories requiring 690V operation and high short-circuit withstand
  • High-rise buildings where intelligent protection prevents cascading outages during faults
  • Power stations using draw-out breakers for safe maintenance and replacement without power interruption
  • Modern intelligent buildings with integrated building management systems using H-type controllers for communication
Technical Features

How It Is Built

  • Rated AC current from 630A to 6300A with 6300A rack rating
  • Short-circuit breaking capacity from 80KA to 120KA depending on model
  • Rated voltage up to AC 690V at 50/60Hz
  • Available in 3-pole and 4-pole configurations
  • Two types: fixed type and draw-out type with dedicated holder structure
  • Operation types: manual and automatic operation
  • Trip types: intelligent controller, under-voltage instant or time-delay trip, shunt trip
  • Intelligent controller categories: L (basic), M (standard), H (communication-ready)
  • Integrated contact system with main and arc contacts made from high-quality materials
  • Parallel contact connection reduces electrical dynamic repulsion forces
  • Contact gap greater than 18mm for improved arc separation
  • Arc-extinguishing chamber per pole for effective arc isolation

Materials and Construction

  • High-quality contact material for main and arc contacts to prevent overheating during short-circuit interruption
  • Flame-retardant housing and insulating components for arc-extinguishing chamber and terminal areas
  • Steel and aluminum alloy used in structural components including side plates, base, and beams
  • Integrated contact system with precision-machined parts for consistent performance
  • Secondary plug and socket assembly for reliable signal and control connection

Quality Control

  • Trip characteristic verification against IEC60947-2 and GB14048.2 requirements
  • Short-circuit breaking capacity tested at rated 80KA to 120KA
  • Mechanical and electrical operation life tested to meet design specifications
  • Insulation and dielectric withstand test performed on every unit
  • Controller communication and protection logic verified in H-type models
  • CCC certification confirmed for all units in the series
Specifications

Stated Ratings for This Model

Specifications for ACB
Standards CompliantIEC60947-2, GB14048.2
Rated VoltageAC 400V, 690V
Frequency50/60Hz
Number of Poles3P, 4P
Rated Current630A to 6300A
Rack Rated Current6300A
Short-circuit Breaking Capacity80KA to 120KA
TypeFixed, Draw-out
Operation TypeManual, Auto
Trip TypeIntelligent controller, Under-voltage instant/time-delay, Shunt trip
Intelligent Controller TypeL (basic), M (standard), H (communication)
Contact SystemIntegrated, parallel connection
Contact GapGreater than 18mm
Arc-extinguishing ChamberPer pole
CertificationsCCC, ISO9001-2000, CE

Ratings are as published for this model. Where a value is not published we mark it TBC rather than estimating it.

Manufacturing Process

  • Moulding and machining of housing, side plates, base, and structural beams
  • Assembly of contact system including main and arc contacts with parallel connection
  • Installation of arc-extinguishing chamber and insulation barriers per pole
  • Integration of operating mechanism, current transformer, and auxiliary switches
  • Mounting of intelligent controller (L/M/H type) and connection to secondary plug
  • Final assembly of draw-out holder or fixed mounting frame
  • Calibration of trip characteristics and controller settings
  • Dielectric and mechanical operation testing before packaging

Customization Options

  • Rated current selected from 630A to 6300A per order
  • Pole count supplied as 3P or 4P from the same series
  • Controller type (L, M, H) selected based on protection and communication needs
  • Draw-out or fixed type configuration chosen at order stage
  • ODM branding on housing and packaging available
  • Packaging and carton marking to buyer’s specification
Comparison

How It Compares

Conventional MCB/MCCBHandles much higher current and breaking capacity, suitable for main distribution rather than branch circuits
Draw-out ACB vs Fixed ACBDraw-out allows for maintenance without power interruption but adds cost and space; fixed is simpler and lower cost
H-type controller vs L-typeH-type adds communication and remote monitoring but increases cost and complexity
ACB vs Switchgear panelACB is a component; panel builders integrate it into a complete system with other devices

Use Guide

  1. Install the fixed or draw-out type breaker in the designated panel or switchgear cabinet
  2. Connect the incoming and outgoing conductors to the appropriate terminals
  3. Ensure the isolating switch is installed and functional as required
  4. Select the appropriate controller type (L, M, H) based on protection and monitoring needs
  5. Configure trip settings and communication parameters via the controller interface
  6. Test operation manually and verify trip response under load
  7. Perform dielectric and insulation tests before energizing the circuit
  8. Keep the trip lock device optional and install as needed for safety
FAQ

Questions About the ACB

What rated currents are available for the ACB

The series covers 630A to 6300A with a 6300A rack rating.

Does it support communication and remote monitoring

Yes, the H-type intelligent controller enables communication and remote monitoring. L and M types are basic and standard without communication.

What types of operation are available

Manual operation and automatic operation are available. Automatic operation is enabled via controller or external signals.

Which standards does it comply with

It conforms to IEC60947-2 and GB14048.2, and has CCC certification across the series.

Can we have it supplied under our own brand

Yes. We support ODM projects and can print your branding on the housing and packaging. Send your artwork and required ratings.

What is the short-circuit breaking capacity

It ranges from 80KA to 120KA depending on the model and rated current.

What are the minimum order quantity and lead time

Both depend on the current rating, pole count, controller type, and branding. Email [email protected] with your model list and quantities for a current answer.

Get a Quotation for the ACB

Tell us the ratings, pole counts and quantities you need and we will price this model directly.