Shanghai Cizen Co., Ltd · Medical Disposables Manufacturer And Supplier
Tracheostomy HME filter with 15F connector
Breathing Filters

Tracheostomy Filter

The tracheostomy filter is a heat and moisture exchanger made for tracheostomised patients breathing spontaneously over a prolonged period. Housing is PP with an HME paper or foam element,…

Product Overview

The tracheostomy filter is a heat and moisture exchanger made for tracheostomised patients breathing spontaneously over a prolonged period. Housing is PP with an HME paper or foam element, weighing 7 g with 15 ml dead space and a 15F connector. Moisture loss is 9.0 mg H2O per litre of air at 500 ml tidal volume, resistance 15 Pa at 30 l/min, recommended tidal volume above 50 ml. EO sterilised.

Product Photography

Photographed from the item we ship, not from a rendering.

Key Benefits

  • 7 g weight puts minimal load on the tracheostomy tube
  • 15 ml dead space suits spontaneous breathing over long periods
  • Moisture loss of only 9.0 mg H2O per litre at 500 ml tidal volume
  • 15F connector fits standard tracheostomy fittings

Problems It Solves

  • Airway drying in tracheostomised patients breathing room air
  • Heavy filters that drag on the tracheostomy tube
  • Dead space too large for a spontaneously breathing patient

Who It Is For

  • Long term ventilation and step-down unit buyers
  • Home and community tracheostomy care distributors
  • ENT and respiratory department stores

Application Scenarios

  • Prolonged use on spontaneously breathing tracheostomy patients
  • Step-down care after weaning from a ventilator
  • Home and long term tracheostomy management

Specifications

Every figure below is taken from the product specification we supply. Where a value is not listed it is confirmed at quotation rather than estimated here.

MaterialHousing: PP, Filter: HME Paper/Form
Recommended Tial Volume(ML)>50
Moisture Loss(mg H20/I air)9.0(@ Vt 500ml)
Resistance(Pa)15 at 30 l/min.
Weight7g
Dead space15ml
Connector15F
UsageA heat and moisture exchanger designed for use on tracheostomised patients. For prolonged use with spontaneously breathing patients and has the following features and benefits: - Suctioning port - Integral swivel oxygen connector - Anti-occlusion mechanism
SterlizationEO
PackagingBlister packing/Middle box/outer carton

Customisation Options

  • HME paper or foam filter element
  • Carton and middle box quantities on request
  • Own-label blister and carton printing

Use Guide

  1. Fit the filter to the 15F tracheostomy connector
  2. Check the recommended tidal volume is above 50 ml before use
  3. Change the filter when secretions load it or per unit protocol
  4. Do not combine with an active humidifier on the same circuit

Compared With Other Options

Heat Moisture Exchanger FilterThe circuit HMEF is built for ventilated patients with 22M/15F connections. This tracheostomy filter is lighter with a 15F connector for spontaneous breathing over a stoma.
FAQ

Questions About The Tracheostomy Filter

What does it weigh?

7 g.

What is the dead space?

15 ml.

What is the connector?

15F.

What moisture loss does it have?

9.0 mg H2O per litre of air at a tidal volume of 500 ml.

What is the recommended tidal volume?

Above 50 ml.

How is it sterilised and packed?

EO sterilised, in blister packing with a middle box and outer carton.

Request A Quote For The Tracheostomy Filter

Send the sizes, configuration and quantity you need. Sample requests go through the same channel.