C14 Right angle
IEC 60320 defines the appliance couplers used on almost every piece of detachable-cord equipment. C13 and C14 are the familiar computer and monitor pair at 10 A, C15 and C16 add a higher temperature rating for kettles and heated equipment, C19 and C20 carry 16 A for servers and PDUs, and the small C5, C7 and C8 couplers serve notebook adaptors and audio equipment.
- Right Angle IEC 60320 C14
- C14 Connector for Class I equipment for cold conditions
- H05VV-F 3G0.75mm2 (Max Length 2Meter)
- H05VV-F 3G1.0mm2
Cord length, cable gauge and type, jacket colour and the connector at the appliance end are set per order. Complete OEM services are available.
Who It Is For
- IT hardware, server and network equipment makers
- Data centre integrators building rack cord looms
- Audio, broadcast and instrument manufacturers
- Distributors stocking replacement kettle leads and jumper cords
Problems It Solves
- Right-angle and locking bodies solve clearance and accidental disconnection in a rack
- One appliance inlet works with cords for every destination market
- Short jumper lengths keep a cabinet tidy instead of coiling excess
- Higher temperature C15 bodies for equipment that runs warm
Where It Is Used
- Servers, switches and rack equipment
- Desktop computers, monitors and printers
- Kettles and heated appliances using C15
- Audio equipment and instrument racks
How It Is Made
The plug is moulded directly onto the cable on our own tooling, so there is no screw joint and no field wiring. The company runs first class producing equipment and advanced mould processing equipment, and quality control is applied at each stage rather than only at the end.
This group covers straight and right-angle bodies, left and right angle variants, and locking C13 connectors that resist being pulled out of a rack outlet. Cords are supplied plug-to-connector or as jumper cords with a connector at both ends.
How we control qualityCustomisation Options
- Cord length to your drawing rather than a fixed catalogue length
- Cable gauge, conductor count and jacket type selected against the load and environment
- Jacket colour and printed marking on request
- Appliance end supplied as an IEC connector, a moulded outlet, ring terminals or stripped and tinned leads
- Retail or bulk packing, with your own artwork where required
Products are RoHS compliant and carry international approvals including UL, cUL, VDE, SAA, BSI, IMQ depending on the destination market. See the certificates.
2004
Exporting since
20+
International approvals
3–4 weeks
Delivery time
12 hours
Enquiry response
Questions About IEC 60320 Power Cords
What is the difference between C13 and C15?
They share the same shape but C15 has a notch and a higher temperature rating, so a C15 cord fits a C14 inlet while a C13 cord will not fit a C16 inlet.
When should I use C19 and C20?
On equipment drawing up to 16 A, typically servers, large UPS units and rack power distribution.
What does a locking C13 do?
It latches into the outlet so the cord cannot be pulled out accidentally when other cables are moved in the rack.
Can you make jumper cords?
Yes. C14 to C13, C20 to C19 and other jumper combinations are standard builds.
Ask About C14 Right angle
Tell us the quantity, the cable and the length. A quotation follows within twelve hours.







