Fuzhou Light Industry Import & Export Co., Ltd. · Cangshan District, Fuzhou, Fujian, China [email protected] +86 183 5008 9245
Viccia Request a Quote
33kV Silicone Combi Unit overview image
Silicon material

33kV Silicone Combi Unit

Combined 33kV drop out fuse and surge arrester in one pole top unit

Product Overview

A combi unit puts the drop out fuse and the surge arrester into a single pole top assembly. Most transformer positions need both - one for the overcurrent from downstream, one for the overvoltage from the line - and combining them cuts the number of mounting points, the number of connections and the time a crew spends at height.

Key Benefits

  • Overcurrent and overvoltage protection at one mounting position
  • Fewer connections and mounting points per pole
  • Silicone housings throughout for polluted environment service
  • Shorter pole top working time per transformer position

Problems It Solves

  • Two separate devices to mount connect and maintain at each position
  • Inconsistent protection arrangements across a network
  • Limited pole top space for separate fuse and arrester assemblies

Application Scenarios

  • 33kV pole mounted transformer protection
  • Positions where both fuse and arrester are required
  • New installations where pole top space is limited
  • Standardising transformer protection across a network

Who It Is For

  • Distribution utilities protecting pole mounted transformers
  • EPC contractors delivering transformer positions
  • Rural electrification projects
  • Maintenance departments standardising positions

Technical Features

  • Combined drop out fuse and surge arrester functions
  • Silicone rubber composite housings
  • Rated at 33kV
  • Single pole top mounting arrangement

Specifications

Product FamilySilicon material
Rated Voltage33kV
Housing MaterialSilicone rubber
ConfigurationFuse and arrester in one mounted unit
FunctionCombined drop out fuse and surge arrester
Dimensions and RatingsConfirmed against your line standard at quotation

Materials

  • Silicone rubber housings
  • Composite insulating cores
  • Arrester blocks and fuse carrier assembly

Manufacturing Process

  • Core and block production
  • Housing moulding
  • Unit assembly
  • Electrical and dimensional check
  • Packing for export

Customisation Options

  • Fuse ratings confirmed against your protection design
  • Arrester rating confirmed against the system voltage and earthing arrangement
  • Supplied as a standard transformer protection package across a project

Compared With Other Options

Separate fuse and arresterSeparate devices give more mounting flexibility. A combi unit reduces the connections and the time at height.
33kV silicone drop out fuse aloneUse the fuse alone where surge protection is provided elsewhere or is not required at that position.

Use Guide

  • Confirm both the fuse rating and the arrester rating before ordering
  • Mount with the shortest practical earth lead from the arrester section
  • Check the fuse carrier drops clear of the arrester and the structure
  • Record the configuration installed at each position
Questions

33kV Silicone Combi Unit Questions

Does a combi unit protect against both fault types

Yes - the fuse section clears downstream overcurrent and the arrester section conducts overvoltage surges to earth. They are different faults and both sections are needed.

Can the fuse section be replaced separately

Fuse links are replaceable in service. Confirm the link type in your enquiry so replacement stock matches.

Is an 11kV combi unit available

Send the requirement with your enquiry and we will confirm what is available at that class.

Get a Price on 33kV Silicone Combi Unit

Send the quantity, the specification you are matching and the destination port.